双层光谱探测器CT预测纯磨玻璃腺癌的侵袭性
回顾性纳入42例患者43个纯磨玻璃结节(pGGN),术前接受双层光谱探测器CT检查并经病理证实,分为微浸润腺癌(MIA)与浸润性腺癌(IA)两组。结果显示病灶不均匀性(OR=48.672,p=0.019)和平扫期电子密度与有效原子序数比值(OR=6.908,p=0.030)是诊断IA的独立预测因子。结论认为双层光谱探测器CT可提示pGGN的侵袭性,病灶不均匀性和平扫期ED-Zeff比值可作为IA的非常特异的鉴别指标。
要点
- 病灶不均匀性和平扫期ED-Zeff比值是诊断IA的独立预测因子。
- 两组间最大直径、CT衰减值、三期ED及ED-Zeff比值、平扫期Zeff和不均匀性均有显著差异。
- 双层光谱探测器CT可提示pGGN的侵袭性,ED-Zeff比值可作为非常特异的鉴别指标。
核心结论
- 双层光谱探测器CT可提示pGGN的侵袭性,病灶不均匀性和平扫期ED-Zeff比值可作为IA的非常特异的鉴别指标。
研究设计与样本
- 回顾性研究,纳入42例患者共43个pGGN,术前接受双层光谱探测器CT检查并经病理证实;结节分为MIA组和IA组,比较光谱CT定量参数并采用ROC曲线分析预测侵袭性的准确性。
关键影像表现/征象
- 肉眼观察碘密度图上的病灶不均匀性。
- 测量平扫期病灶最大直径和CT衰减值。
- 获取动脉期和静脉期的标准化碘浓度(NIC),以及平扫期、动脉期和静脉期的有效原子序数(Zeff)、电子密度(ED)和ED-Zeff比值。
诊断标准与关键数值
- 病灶不均匀性诊断IA的OR=48.672(p=0.019),为独立预测因子。
- 平扫期ED-Zeff比值诊断IA的OR=6.908(p=0.030),为独立预测因子。
- 两组间最大直径、CT衰减值、三期ED及ED-Zeff比值、平扫期Zeff和不均匀性差异有统计学意义。
临床应用与阅片要点
- 阅片时可关注碘密度图上病灶是否均匀,不均匀性为IA的独立预测因子。
- 平扫期ED-Zeff比值可作为鉴别IA的定量指标,其OR=6.908。
- 双层光谱探测器CT可提示pGGN的侵袭性,帮助术前评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate the clinical application of novel dual-layer spectral detector computed tomography (CT) for differentiating the invasiveness of pure ground-glass nodules (pGGNs).
MATERIALS AND METHODS: A total of 42 patients with 43 pGGNs, who underwent preoperative dual-layer spectral detector CT and were identified by pathology, were evaluated retrospectively. The nodules were divided into two groups: minimally invasive adenocarcinoma (MIA) and invasive adenocarcinoma (IA). Lesion inhomogeneity was observed visually on the iodine density map. Normalised iodine concentrations (NICs) in the arterial and venous phases and the effective atomic number (Zeff), electron density (ED), and the ED-Zeff ratio in the plain, arterial and venous phases were obtained. The maximum diameter and CT attenuation of the lesion in the plain phase were measured. Receiver operating characteristic (ROC) curves were used to analyse the accuracy of spectral CT quantitative parameters in predicting the invasiveness of lung adenocarcinoma manifesting as pGGNs.
RESULTS: There were significant differences in the maximum diameter, CT attenuation value, ED and the ED-Zeff ratio in three phase, Zeff in the plain phase, and inhomogeneity between the two groups. Lesion inhomogeneity (odds ratio [OR] = 48.672, p=0.019) and the ED-Zeff ratio (OR=6.908, p=0.030) in the plain phase were independent predictors for diagnosing IA manifesting as pGGNs.
CONCLUSIONS: Novel dual-layer spectral detector CT can indicate the invasiveness of pGGNs. Lesion inhomogeneity and the ratio of the ED to Zeff in the plain phase can serve as very specific discriminators of IA manifesting as pGGN.
引用
- Yu, Fu, Chen, et al. Dual-layer spectral detector CT: predicting the invasiveness of pure ground-glass adenocarcinoma. Clin Radiol. 2022. PMID: 35277263. doi:10.1016/j.crad.2022.02.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。