文献速递心血管CT

人工智能在多期相CT上测量心房颤动患者左心房容积与功能的诊断准确性和性能

Diagnostic accuracy and performance of artificial intelligence in measuring left atrial volumes and function on multiphasic CT in patients with atrial fibrillation.
PubMed 文献 · Eur Radiol · 2022-03-11

这项回顾性研究纳入79例患者(35例心房颤动,44例对照),评估一种新型人工智能算法在心脏CT上全自动测量左心房容积与功能的效果。人工智能测量速度显著快于手动测量(4秒 vs 10.8分钟),与手动测量的一致性总体良好至优秀,在心房颤动患者中一致性更强(ICC≥0.877)且容积估计与手动测量相差在1.3 mL以内;人工智能与专家利用左心房容积指数区分心房颤动患者与对照的能力相似(AUC 0.81 vs 0.82,p=0.62)。

要点

  • 人工智能全自动测量左心房容积仅需4秒,手动测量需10.8分钟
  • 人工智能与手动测量一致性良好至优秀,心房颤动患者中ICC≥0.877
  • 人工智能区分心房颤动与对照的AUC为0.81,与专家0.82相似(p=0.62)

核心结论

  • 新型人工智能算法可高效完成基于多期相CT的左心房容积与功能全自动定量,其准确性与手动定量相似。

研究设计与样本

  • 回顾性研究,纳入2017年至2020年间79例患者(平均年龄63±12岁;35例心房颤动,44例对照),由训练有素的人工智能算法与一名专家放射科医生分析心脏CT图像。

诊断标准与关键数值

  • 人工智能与手动测量总体一致性良好至优秀,心房颤动患者所有ICC≥0.877(p<0.001),对照组所有ICC≥0.799(p<0.001);人工智能在心房颤动患者中估计左心房容积与手动测量相差均在1.3 mL以内,在对照组中高估容积均≤4.2 mL;利用左心房容积指数区分心房颤动患者与对照的AUC人工智能为0.81,专家为0.82(p=0.62)。

临床应用与阅片要点

  • 人工智能可快速全自动获得左心房容积与功能参数,与手动测量一致性良好至优秀,在心房颤动患者中容积估计与手动测量相差在1.3 mL以内。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the effectiveness of a novel artificial intelligence (AI) algorithm for fully automated measurement of left atrial (LA) volumes and function using cardiac CT in patients with atrial fibrillation.

METHODS: We included 79 patients (mean age 63 ± 12 years; 35 with atrial fibrillation (AF) and 44 controls) between 2017 and 2020 in this retrospective study. Images were analyzed by a trained AI algorithm and an expert radiologist. Left atrial volumes were obtained at cardiac end-systole, end-diastole, and pre-atrial contraction, which were then used to obtain LA function indices. Intraclass correlation coefficient (ICC) analysis of the LA volumes and function parameters was performed and receiver operating characteristic (ROC) curve analysis was used to compare the ability to detect AF patients.

RESULTS: The AI was significantly faster than manual measurement of LA volumes (4 s vs 10.8 min, respectively). Agreement between the manual and automated methods was good to excellent overall, and there was stronger agreement in AF patients (all ICCs ≥ 0.877; p < 0.001) than controls (all ICCs ≥ 0.799; p < 0.001). The AI comparably estimated LA volumes in AF patients (all within 1.3 mL of the manual measurement), but overestimated volumes by clinically negligible amounts in controls (all by ≤ 4.2 mL). The AI's ability to distinguish AF patients from controls using the LA volume index was similar to the expert's (AUC 0.81 vs 0.82, respectively; p = 0.62).

CONCLUSION: The novel AI algorithm efficiently performed fully automated multiphasic CT-based quantification of left atrial volume and function with similar accuracy as compared to manual quantification. Novel CT-based AI algorithm efficiently quantifies left atrial volumes and function with similar accuracy as manual quantification in controls and atrial fibrillation patients.

KEY POINTS: • There was good-to-excellent agreement between manual and automated methods for left atrial volume quantification. • The AI comparably estimated LA volumes in AF patients, but overestimated volumes by clinically negligible amounts in controls. • The AI's ability to distinguish AF patients from controls was similar to the manual methods.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Aquino, Chamberlin, Yacoub, et al. Diagnostic accuracy and performance of artificial intelligence in measuring left atrial volumes and function on multiphasic CT in patients with atrial fibrillation. Eur Radiol. 2022. PMID: 35275258. doi:10.1007/s00330-022-08657-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。