文献速递胸部介入CT

电视辅助胸腔镜手术前使用肺结节定位针标记磨玻璃结节

Marking ground glass nodules with pulmonary nodules localization needle prior to video-assisted thoracoscopic surgery.
PubMed 文献 · Eur Radiol · 2022-03-10

回顾性分析2020年6月至2021年2月352例患者395枚磨玻璃结节,术前CT引导下用肺结节定位针标记后行电视辅助胸腔镜手术。标记成功率99.0%(391/395),失败4枚均因定位针位置不理想,无标记物移位;并发症均为轻微,包括气胸63例(17.9%)、出血34例(9.7%)、咯血6例(1.7%),无需特殊处理。结论认为该定位方法安全可靠,可有效指导电视辅助胸腔镜手术切除磨玻璃结节。

要点

  • 肺结节定位针标记磨玻璃结节成功率高(99.0%),无标记物移位。
  • 并发症轻微,气胸17.9%、出血9.7%、咯血1.7%,均无需特殊处理。
  • 标记后2至3天仍可进行电视辅助胸腔镜手术。

核心结论

  • 术前使用肺结节定位针定位磨玻璃结节安全可靠,能有效指导电视辅助胸腔镜手术切除磨玻璃结节。

研究设计与样本

  • 回顾性分析,纳入2020年6月至2021年2月连续352例患者共395枚磨玻璃结节,术前CT引导下使用肺结节定位针标记,随后行电视辅助胸腔镜手术;以病理组织学检查为参考标准。

诊断标准与关键数值

  • 标记成功率99.0%(391/395);标记失败4枚均因定位针位置不理想;无标记物移位;磨玻璃结节平均直径0.95±0.48 cm,距胸膜最短距离1.73±0.96 cm;标记所需时间7.8±2.2 min;病理结果良性74枚(18.7%)、恶性321枚(81.3%)。

临床应用与阅片要点

  • 术前CT引导下肺结节定位针标记可有效指导电视辅助胸腔镜手术切除磨玻璃结节,标记后2至3天可行手术;并发症轻微且无需特殊处理。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the efficacy and safety of marking ground glass nodules (GGNs) with pulmonary nodules localization needle (PNLN) prior to video-assisted thoracoscopic surgery (VATS).

MATERIALS AND METHODS: From June 2020 to February 2021, all patients with GGNs who received CT-guided localization using PNLN before VATS were enrolled. Clinical and imaging data were retrospectively analyzed.

RESULTS: A total of 352 consecutive patients with 395 GGNs were included in the study. The mean diameter of GGNs was 0.95 ± 0.48 cm, and the shortest distance from nodules to the pleura was 1.73 ± 0.96 cm. All 395 GGNs were marked using PNLNs. The time required for marking was 7.8 ± 2.2 min. The marking success rate was 99.0% (391/395). The marking failure of four nodules was all due to the unsatisfactory position of PNLNs. No marker dislocation occurred. Marking-related complications included pneumothorax in 63 cases (17.9%), hemorrhage in 34 cases (9.7%), and hemoptysis in 6 cases (1.7%). All the complications were minor and did not need special treatment. Localization and VATS were performed on the same day in 95 cases and on different days in 257 cases. All GGNs were successfully removed by VATS. No patient converted to thoracotomy. Histopathological examination revealed 74 (18.7%) benign nodules and 321 (81.3%) malignant nodules.

CONCLUSIONS: It is safe and reliable to perform preoperative localization of GGNs using PNLNs, which can effectively guide VATS to remove GGNs.

KEY POINTS: • Preoperative localization of GGNs could effectively guide VATS to remove GGNs. • PNLN was based on the marking principle of hook-wire, through the improvement of its material, specially designed to mark pulmonary nodules. • The application of PNLN to mark GGNs had high success rate, good patient tolerance, and no dislocation. Meanwhile, VATS could be performed 2 to 3 days after marking GGNs with PNLN.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Li, Huang, Sun, et al. Marking ground glass nodules with pulmonary nodules localization needle prior to video-assisted thoracoscopic surgery. Eur Radiol. 2022. PMID: 35267089. doi:10.1007/s00330-022-08597-7