不同经验放射科医师对≤30 mm肝脏结节CEUS LI-RADS的诊断效能与阅片者间一致性

Diagnostic performance and interreader agreement of CEUS LI-RADS in ≤ 30 mm liver nodules with different experienced radiologists.
PubMed 文献 · Abdom Radiol (NY) · 2022-03-08

研究纳入2018年1月至2020年10月244例HCC高危并接受CEUS的患者,由2名新手和2名专家放射科医师独立评估LI-RADS分类及主要特征。结果显示LI-RADS分类的阅片者间一致性为显著至几乎完全一致(κ 0.78-0.88),以CEUS LR-5诊断HCC时各医师间敏感度、特异度、准确率、PPV和NPV无统计学差异(p>0.05),但Reader 4与其余三名医师在准确率和敏感度上存在差异(p<0.05)。

要点

  • CEUS LI-RADS分类在≤30 mm肝脏结节中阅片者间一致性为显著至几乎完全一致(κ 0.78-0.88)。
  • 以CEUS LR-5诊断HCC,各医师间敏感度、特异度、准确率、PPV、NPV无统计学差异(p>0.05)。
  • Reader 4与其余三名医师在准确率和敏感度上存在统计学差异(p<0.05)。

核心结论

  • CEUS LI-RADS在经验丰富的放射科医师中对≤30 mm肝脏结节的诊断一致性良好。

研究设计与样本

  • 研究纳入2018年1月至2020年10月244例HCC高危并接受CEUS的患者,由2名新手和2名专家放射科医师独立评估LI-RADS分类及主要特征;采用Kappa和Kendall检验评估阅片者间一致性,基于敏感度、特异度、准确率、PPV和NPV确定诊断效能。

诊断标准与关键数值

  • 以CEUS LR-5作为HCC诊断标准时,各医师间敏感度、特异度、准确率、PPV和NPV无统计学差异(p>0.05),但Reader 4与其余三名医师在准确率和敏感度上存在差异(p<0.05)。
  • 动脉期高增强、晚且轻度廓清、早期廓清和环状高增强的阅片者间一致性为中等至几乎完全一致(κ 0.44-0.93)。
  • LI-RADS分类的阅片者间一致性为显著至几乎完全一致(κ 0.78-0.88)。
  • 明显廓清的阅片者间一致性为一般至中等(κ 0.28-0.50)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To explore the diagnostic performance and interreader agreement of CEUS LI-RADS in diagnosing ≤ 30 mm liver nodules with different experienced radiologists.

METHODS: Between January 2018 and October 2020, 244 patients at high-risk for HCC who underwent CEUS were enrolled. Two novice radiologists and two expert radiologists independently evaluated LI-RADS categories and main features. Kappa (κ) and Kendall's tests were employed to evaluate the interreader agreement of CEUS LI-RADS. The diagnostic performance was determined based on sensitivity, specificity, accuracy, PPV and NPV.

RESULTS: The interreader agreement for arterial phase hyperenhancement, late and mild washout, early washout, and rim hyperenhancement was moderate to almost perfect (κ, 0.44-0.93) among the different levels of radiologists. The interreader agreement for the LI-RADS categories was substantial to almost perfect (κ, 0.78-0.88). However, the interreader agreement for marked washout was fair to moderate (κ, 0.28-0.50). When CEUS LR-5 was used as a diagnostic criterion for HCC, there were no statistical differences in sensitivity, specificity, accuracy, PPV and NPV among the radiologists (p > 0.05), except for the differences between Reader 4 and the remaining three radiologists in terms of accuracy and sensitivity (p < 0.05).

CONCLUSION: CEUS LI-RADS has good diagnostic agreement for ≤ 30 mm liver nodules among experienced radiologists.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。