文献速递骨肌神经PETCT

腰骶交界处的定量测量是识别和编号腰骶移行椎更可靠的参数

Quantitative measurements at the lumbosacral junction are more reliable parameters for identifying and numbering lumbosacral transitional vertebrae.
PubMed 文献 · Eur Radiol · 2022-03-08

回顾2845例PET/CT扫描,纳入23和25枚骶前椎骨患者,评估最低腰椎型椎体前缘角(AVA)、最上骶椎型椎体下终板与上终板长度比值(RISE)及腰骶椎间盘角(LSIVDA)等定量参数与解剖标志识别腰骶移行椎(LSTV)的能力。AVA和RISE在LSTV组与对照组及LSTV亚组间差异显著;区分L5骶化与S1腰化时,AVA阈值73.0°的准确度、敏感度、特异度分别为91.1%、77.5%、88.3%,RISE阈值0.79分别为90.3%、77.5%、94.2%。结论认为定量测量可能比解剖标志更有助于区分LSTV亚组。

要点

  • AVA阈值73.0°区分L5骶化与S1腰化:准确度91.1%,敏感度77.5%,特异度88.3%。
  • RISE阈值0.79区分L5骶化与S1腰化:准确度90.3%,敏感度77.5%,特异度94.2%。
  • AVA和RISE在LSTV组与对照组及LSTV亚组间差异显著,且阅片者内和阅片者间信度高。

核心结论

  • 与解剖标志相比,腰骶交界处的定量测量(包括AVA和RISE)可能更有助于区分LSTV亚组,尤其在仅有腰椎影像时。

研究设计与样本

  • 回顾性分析2845例PET/CT扫描,纳入23和25枚骶前椎骨患者,评估定量参数(AVA、RISE、LSIVDA)和解剖标志(髂嵴切线水平、髂腰韧带起点水平、腰大肌近端附着)识别LSTV的能力。

关键影像表现/征象

  • AVA为最低腰椎型椎体前缘角,RISE为最上骶椎型椎体下终板与上终板长度比值,LSIVDA为腰骶椎间盘角。
  • AVA和RISE在LSTV组与对照组间及LSTV亚组间差异显著。

诊断标准与关键数值

  • 区分L5骶化与S1腰化:AVA阈值73.0°,准确度91.1%,敏感度77.5%,特异度88.3%。
  • 区分L5骶化与S1腰化:RISE阈值0.79,准确度90.3%,敏感度77.5%,特异度94.2%。
  • 区分L5骶化与S1腰化:LSIVDA阈值14.15°,准确度75.9%,敏感度65.7%,特异度78.3%。
  • 区分对照组与LSTV:髂嵴切线水平准确度78.0%,敏感度70.2%,特异度95.0%;腰大肌近端附着准确度71.7%,敏感度61.7%,特异度94.0%。

临床应用与阅片要点

  • AVA和RISE易于评估,阅片者内和阅片者间信度高。
  • 定量测量AVA和RISE可能比解剖标志更有助于区分LSTV亚组,尤其在仅有腰椎影像时。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate quantitative parameters to identify the anatomic variation lumbosacral transitional vertebrae (LSTV) and compare them with the landmarks commonly used at present.

METHODS: A total of 2,845 PET/CT scans were reviewed, and the patients with 23 and 25 presacral vertebrae were included. The quantitative parameters, including the anterior-edge vertebral angle (AVA) of the lowest lumbar-type vertebra, the ratio of the length of the inferior endplate to that of the superior endplate (RISE) of the uppermost sacral-type vertebra and the lumbosacral intervertebral disc angle (LSIVDA), and the anatomical landmarks, including the iliac crest tangent (ICT) level, the iliolumbar ligament (ILL) origin level and psoas proximal insertion, were all evaluated to determine their ability to identify LSTV.

RESULTS: The values of AVA and RISE were significantly different between the LSTV group and the control group, and between subgroups of LSTV. The cutoff value for AVA was 73.0°, with an accuracy, sensitivity, and specificity of 91.1%, 77.5%, and 88.3%, and that for RISE was 0.79, with an accuracy, sensitivity, and specificity of 90.3%, 77.5%, and 94.2%, while that for LSIVDA was 14.15°, with an accuracy, sensitivity, and specificity of 75.9%, 65.7%, and 78.3%, to differentiate L5 sacralization from S1 lumbarization. For differentiating the controls from LSTV, the accuracy, sensitivity, and specificity of the ICT level and proximal psoas insertion were 78.0%, 70.2%, and 95.0%, versus 71.7%, 61.7%, and 94.0%.

CONCLUSIONS: Compared with the anatomical landmarks, the quantitative measurements at the lumbosacral junction, including AVA and RISE, may be more helpful for differentiating subgroups of LSTV especially if only lumbar spine imaging is available.

KEY POINTS: • The quantitative parameters, the anterior-edge vertebral angle (AVA) of the lowest lumbar-type vertebra and the ratio of the length of the inferior endplate to that of the superior endplate (RISE) of the uppermost sacral-type vertebra, are more helpful for distinguishing L5 sacralization from S1 lumbarization than the previously proposed anatomic landmarks. • AVA and RISE represent relevant changes in the curvature at the lumbosacral region and the shape of the transitional vertebral body, respectively. • AVA and RISE are easily assessed, with high intra- and inter-reader reliability.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Zhou, Du, Liu, et al. Quantitative measurements at the lumbosacral junction are more reliable parameters for identifying and numbering lumbosacral transitional vertebrae. Eur Radiol. 2022. PMID: 35258678. doi:10.1007/s00330-022-08613-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。