文献速递乳腺MR

基于最大强度投影MR图像的人工智能系统助力非肿块强化乳腺病灶分类

An artificial intelligence system using maximum intensity projection MR images facilitates classification of non-mass enhancement breast lesions.
PubMed 文献 · Eur Radiol · 2022-03-08

本回顾性研究纳入903例女性965个经病理或随访证实的纯非肿块强化病灶,利用早期增强后减影乳腺MR的最大强度投影图像构建ResNet-50人工智能系统,在两个测试集AUC分别为0.859和0.816,与高年资放射科医师表现相当并优于低年资医师,且可提升低年资医师诊断效能。

要点

  • 基于MIP图像的AI系统在测试集A和B的AUC分别为0.859和0.816。
  • AI系统与高年资医师表现相当,在两个测试集均优于低年资医师。
  • AI辅助后低年资医师AUC由0.740升至0.862(测试集A)、由0.732升至0.843(测试集B)。

核心结论

  • 基于MIP的AI系统在分类非肿块强化乳腺病灶方面具有良好适用性,可帮助低年资放射科医师获得更好的诊断表现。

研究设计与样本

  • 回顾性研究,纳入903例女性965个经组织病理学或随访证实的纯非肿块强化病灶(良性539个、恶性426个),其中754个病灶来自一台MR扫描仪并随机分为训练集、验证集和测试集A(482/121/151个病灶),另211个病灶来自另一台MR扫描仪作为测试集B。

诊断标准与关键数值

  • AI系统基于ResNet-50并使用轴位和矢状位MIP图像构建;测试集A的AUC为0.859,测试集B的AUC为0.816;AI系统与高年资放射科医师比较P=0.558(测试集A)和P=0.041(测试集B),与低年资放射科医师比较P<0.001(测试集A)和P=0.009(测试集B);AI辅助后低年资医师AUC在测试集A由0.740升至0.862(P<0.001),在测试集B由0.732升至0.843(P<0.001)。

临床应用与阅片要点

  • 作者结论认为该基于MIP的AI系统在分类非肿块强化乳腺病灶方面具有良好适用性,并可帮助低年资放射科医师获得更好的诊断表现。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To build an artificial intelligence (AI) system to classify benign and malignant non-mass enhancement (NME) lesions using maximum intensity projection (MIP) of early post-contrast subtracted breast MR images.

METHODS: This retrospective study collected 965 pure NME lesions (539 benign and 426 malignant) confirmed by histopathology or follow-up in 903 women. The 754 NME lesions acquired by one MR scanner were randomly split into the training set, validation set, and test set A (482/121/151 lesions). The 211 NME lesions acquired by another MR scanner were used as test set B. The AI system was developed using ResNet-50 with the axial and sagittal MIP images. One senior and one junior radiologist reviewed the MIP images of each case independently and rated its Breast Imaging Reporting and Data System category. The performance of the AI system and the radiologists was evaluated using the area under the receiver operating characteristic curve (AUC).

RESULTS: The AI system yielded AUCs of 0.859 and 0.816 in the test sets A and B, respectively. The AI system achieved comparable performance as the senior radiologist (p = 0.558, p = 0.041) and outperformed the junior radiologist (p < 0.001, p = 0.009) in both test sets A and B. After AI assistance, the AUC of the junior radiologist increased from 0.740 to 0.862 in test set A (p < 0.001) and from 0.732 to 0.843 in test set B (p < 0.001).

CONCLUSION: Our MIP-based AI system yielded good applicability in classifying NME lesions in breast MRI and can assist the junior radiologist achieve better performance.

KEY POINTS: • Our MIP-based AI system yielded good applicability in the dataset both from the same and a different MR scanner in predicting malignant NME lesions. • The AI system achieved comparable diagnostic performance with the senior radiologist and outperformed the junior radiologist. • This AI system can assist the junior radiologist achieve better performance in the classification of NME lesions in MRI.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Wang, Chang, Luo, et al. An artificial intelligence system using maximum intensity projection MR images facilitates classification of non-mass enhancement breast lesions. Eur Radiol. 2022. PMID: 35258676. doi:10.1007/s00330-022-08553-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。