时间依赖性扩散MRI用于前列腺癌定量微结构成像
前瞻性纳入48例临床怀疑前列腺癌的男性,在3.0-T扫描仪上以7.5-30毫秒等效扩散时间采集脉冲和振荡梯度扩散MRI数据,用双室模型估计细胞直径、细胞内体积分数、细胞密度和扩散率。高级别GG与更高的细胞内体积分数和细胞密度相关,细胞密度鉴别临床显著前列腺癌(GG>1)的准确度为92%(44/48),AUC为0.96(95%CI:0.87,0.99)。
要点
- 细胞密度鉴别临床显著前列腺癌(GG>1)准确度92%(44/48),AUC 0.96(95%CI:0.87,0.99)。
- GG越高细胞内体积分数和细胞密度越高,细胞直径越低。
- 时间依赖性扩散MRI微结构参数与病理测量结果正相关(r=0.83;P<.001)。
核心结论
- 时间依赖性扩散MRI微结构成像与病理结果相关,在前列腺癌表征方面展现出潜力。
研究设计与样本
- 前瞻性研究,2019年10月至2020年8月纳入48例临床怀疑前列腺癌的男性,在3.0-T扫描仪上以7.5-30毫秒等效扩散时间采集脉冲和振荡梯度扩散MRI序列,用双室模型估计微结构参数,以线性判别分析评估鉴别临床显著前列腺癌(GG>1)与临床不显著病变(良性及GG 1)的效能,并与组织病理测量结果做相关性验证。
诊断标准与关键数值
- 细胞内体积分数在GG 1-5分别为0.22、0.36、0.34、0.37和0.40,单因素方差分析P<.001。
- 细胞直径在GG 1-5分别为23.4、18.3、19.2、17.9和18.5 μm,P=.002。
- 细胞密度鉴别临床显著前列腺癌(GG>1)与临床不显著病变(良性及GG 1)的准确度为92%(44/48),AUC为0.96(95%CI:0.87,0.99)。
- 时间依赖性扩散MRI与病理检查的细胞内体积分数呈正相关(r=0.83;P<.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Recently developed time-dependent diffusion MRI has potential in characterizing cellular tissue microstructures; however, its value in imaging prostate cancer (PCa) remains unknown. Purpose To investigate the feasibility of time-dependent diffusion MRI-based microstructural mapping for noninvasively characterizing cellular properties of PCa and for discriminating between clinically significant PCa and clinically insignificant disease. Materials and Methods Men with a clinical suspicion of PCa were enrolled prospectively between October 2019 and August 2020. Time-dependent diffusion MRI data were acquired with pulsed and oscillating gradient diffusion MRI sequences at an equivalent diffusion time of 7.5-30 msec on a 3.0-T scanner. Time-dependent diffusion MRI-based microstructural parameters, including cell diameter, intracellular volume fraction, cellularity, and diffusivities, were estimated with a two-compartment model. These were compared for different International Society of Urological Pathology grade groups (GGs), and their performance in discriminating clinically significant PCa (GG >1) from clinically insignificant disease (benign and GG 1) was determined with a linear discriminant analysis. The fitted microstructural parameters were validated by means of correlation with histopathologic measurements. Results In the 48 enrolled men, the time-dependent diffusion MRI measurements showed that higher GG was correlated with higher intracellular volume fraction and higher cellularity (intracellular volume fraction = 0.22, 0.36, 0.34, 0.37, and 0.40 in GGs 1-5, respectively; P < .001 at one-way analysis of variance), while lower cell diameter was found at higher GGs (diameter = 23.4, 18.3, 19.2, 17.9, and 18.5 μm in GGs 1-5, respectively; P = .002). Among all measurements derived from time-dependent diffusion MRI, cellularity achieved the highest diagnostic performance, with an accuracy of 92% (44 of 48 participants) and area under the receiver operating characteristic curve of 0.96 (95% CI: 0.87, 0.99) in discriminating clinically significant PCa from clinically insignificant disease. Microstructural mapping was supported by positive correlations between time-dependent diffusion MRI-based and pathologic examination-based intracellular volume fraction (r = 0.83; P < .001). Conclusion Time-dependent diffusion MRI-based microstructural mapping correlates with pathologic findings and demonstrates promise for characterizing prostate cancer. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Chatterjee and Oto in this issue.
引用
- Wu, Jiang, Li, et al. Time-Dependent Diffusion MRI for Quantitative Microstructural Mapping of Prostate Cancer. Radiology. 2022. PMID: 35258368. doi:10.1148/radiol.211180
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。