文献速递胸部神经CT

脊髓延髓肌萎缩症中乳腺增生的CT定量与形态学评估

Quantitative and Morphological Assessment of Computed Tomography-depicted Gynecomastia in Spinal and Bulbar Muscular Atrophy.
PubMed 文献 · Acad Radiol · 2022-03-01

研究纳入189例男性患者(脊髓延髓肌萎缩症15例、肌萎缩侧索硬化76例、重症肌无力对照98例),在胸部CT上比较乳腺腺体直径及乳腺增生特征。多因素分析显示乳腺增生患病率、树枝状或弥漫型模式及双侧乳腺增生与脊髓延髓肌萎缩症正相关,平均乳腺腺体直径预测该病的AUC为0.92,最佳截断值16.5 mm。结论提示胸部CT评估乳腺腺体组织可作为筛查检查,辅助鉴别诊断脊髓延髓肌萎缩症。

要点

  • 胸部CT上平均乳腺腺体直径>16.5 mm预测脊髓延髓肌萎缩症的AUC为0.92。
  • 树枝状或弥漫型乳腺增生模式与该病强相关(aOR 35.30)。
  • 双侧乳腺增生与该病强相关(aOR 41.96),但非肌萎缩侧索硬化。

核心结论

  • 胸部CT评估乳腺腺体组织可作为筛查检查,用于区分脊髓延髓肌萎缩症患者并辅助其鉴别诊断。

研究设计与样本

  • 回顾性比较研究,纳入189例男性患者(脊髓延髓肌萎缩症15例、肌萎缩侧索硬化76例、对照98例),均行胸部CT,比较乳腺腺体组织直径及CT表现特征。

关键影像表现/征象

  • CT上可见乳腺增生表现为树枝状或弥漫型模式,并可呈双侧分布;脊髓延髓肌萎缩症组平均及最大乳腺腺体直径增大,乳腺增生患病率更高。

诊断标准与关键数值

  • 多因素logistic回归显示平均乳腺腺体直径aOR 1.13(95%CI 1.08-1.19)、最大乳腺腺体直径aOR 1.14(95%CI 1.08-1.20)、CT所示乳腺增生患病率aOR 21.71(95%CI 5.39-87.38)、树枝状或弥漫型模式aOR 35.30(95%CI 8.02-155.40)、双侧乳腺增生aOR 41.96(95%CI 10.20-172.69)均与脊髓延髓肌萎缩症正相关,与肌萎缩侧索硬化无关;平均乳腺组织直径预测该病的AUC为0.92,最佳截断值16.5 mm;最大乳腺组织直径18.6 mm也可有效区分该病与对照。

临床应用与阅片要点

  • 阅读胸部CT时注意测量乳腺腺体组织直径并观察有无树枝状或弥漫型、双侧乳腺增生,平均直径>16.5 mm或最大直径>18.6 mm时提示脊髓延髓肌萎缩症可能,可辅助鉴别诊断。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate the prevalence, size, and characteristics of gynecomastia on thoracic computed tomography (CT) in patients with spinal and bulbar muscular atrophy (SBMA) or amyotrophic lateral sclerosis (ALS), compared to those of patients with myasthenia gravis (as controls).

MATERIALS AND METHODS: A total of 189 male patients (SBMA [n = 15]; ALS [n = 76]; control [n = 98]) who underwent thoracic computed tomography were included. The size of breast glandular tissue diameters, and characteristic of CT-depicted gynecomastia were compared.

RESULTS: On multivariate logistic regression analysis, mean breast glandular tissue diameter (adjusted odds ratio [aOR] 1.13, 95% confidence interval [CI] 1.08-1.19), maximum breast glandular tissue diameter (aOR 1.14, 95% CI 1.08-1.20), prevalence of CT-depicted gynecomastia (aOR 21.71, 95% CI 5.39-87.38), dendritic or diffuse pattern of gynecomastia (aOR 35.30, 95% CI 8.02-155.40), and bilateral gynecomastia (aOR 41.96, 95% CI 10.20-172.69) were positively associated with SBMA, but not ALS. On receiver operating characteristic (ROC) analysis, the area under the curve of the mean breast tissue diameter for predicting SBMA was 0.92 with the optimal cutoff value of 16.5 mm. The ROC analysis showed that a maximum breast tissue diameter of 18.6 mm can also effectively distinguish SBMA from controls.

CONCLUSION: These findings suggest that the evaluation of breast glandular tissue on thoracic CT could be a screening examination to distinguish SBMA patients and assist in its differential diagnosis.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Iida, Nakamura, Itani, et al. Quantitative and Morphological Assessment of Computed Tomography-depicted Gynecomastia in Spinal and Bulbar Muscular Atrophy. Acad Radiol. 2022. PMID: 35246377. doi:10.1016/j.acra.2022.02.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。