文献速递腹部泌尿生殖CT

肾细胞癌微波消融后分次团注CT尿路造影可提高图像质量并降低辐射剂量

Split-bolus CT urography after microwave ablation of renal cell carcinoma improves image quality and reduces radiation exposure.
PubMed 文献 · Abdom Radiol (NY) · 2022-03-03

该研究比较了临床局限性T1肾细胞癌微波消融后单次团注两期与分次团注一期CT尿路造影的图像质量和辐射剂量。分次团注一期CTU在肾盂充盈程度、扩张程度、肾实质强化和主观图像质量上均更优,且SSDE显著更低。

要点

  • 分次团注一期CTU较单次团注两期CTU主观图像质量更优(3.2 vs 4.0,p=0.004)。
  • 分次团注CTU肾盂充盈(2.5 vs 3.5,p<0.001)与扩张(4 mm vs 8 mm,p<0.001)更佳。
  • 分次团注CTU平均SSDE显著更低(163.9 mGy vs 36.3 mGy,p<0.001)。

核心结论

  • 分次团注CTU在cT1肾细胞癌微波消融后立即进行,可获得更高图像质量、更好的集合系统充盈/扩张和肾实质强化,且辐射剂量更低。

研究设计与样本

  • 研究论文;42例连续患者(30例男性,平均年龄67.5±9.0岁)cT1肾细胞癌,2013年7月至2013年12月在两家学术四级医疗中心接受微波消融;比较单次团注两期与分次团注一期CTU;采用Kruskal-Wallis检验、Pearson卡方检验和等方差两样本t检验。

关键影像表现/征象

  • 分次团注组中位肿瘤直径更大(2.9 cm,IQR 1.7-5.3 vs 3.6 cm,IQR 1.7-5.7,p=0.01)。
  • 两组平均腹围相似(p=0.20),使用的天线数量和微波消融前后获取的平扫CT数量相似(p=0.11-0.32)。
  • 分次团注CTU肾盂充盈(2.5 vs 3.5,p<0.001)和扩张(4 mm vs 8 mm,p<0.001)改善。
  • 分次团注CTU肾实质强化更高(右侧:127 HU vs 177 HU,p=0.001;左侧:124 HU vs 185 HU,p<0.001)。
  • 分次团注CTU主观图像质量更优(3.2 vs 4.0,p=0.004)。

诊断标准与关键数值

  • 分次团注CTU平均SSDE显著低于单次团注CTU(163.9 mGy,SD±73.9 vs 36.3 mGy,SD±7.7,p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare image quality and radiation dose between single-bolus 2-phase and split-bolus 1-phase CT Urography (CTU) performed immediately after microwave ablation (MWA) of clinically localized T1 (cT1) RCC.

METHODS: Forty-two consecutive patients (30 M, mean age 67.5 ± 9.0) with cT1 RCC were treated with MWA from 7/2013 to 12/2013 at two academic quaternary-care institutions. Renal parenchymal enhancement, collecting system opacification and distention and size-specific dose estimate (SSDE) were quantified and image quality subjectively assessed on single-bolus 2-phase versus split-bolus 1-phase CTU. Kruskal-Wallis and Pearson's Chi-squared tests were performed to assess differences in continuous and categorical variables, respectively. Two-sample T test with equal variances was used to determine differences in quantitative and qualitative image data.

RESULTS: Median tumor diameter was larger [2.9 cm (IQR 1.7-5.3) vs 3.6 cm (IQR 1.7-5.7), p = 0.01] in the split-bolus cohort. Mean abdominal girth (p = 0.20) was similar. Number of antennas used and unenhanced CTs obtained before and during MWA were similar (p = 0.11-0.32). Renal pelvis opacification (2.5 vs 3.5, p < 0.001) and distention (4 mm vs 8 mm, p < 0.001) were improved and renal enhancement (Right: 127 HU vs 177 HU, p = 0.001; Left: 124 HU vs 185 HU, p < 0.001) was higher for the split-bolus CTU. Image quality was superior for split-bolus CTU (3.2 vs 4.0, p = 0.004). Mean SSDE for the split-bolus CTU was significantly lower [163.9 mGy (SD ± 73.9) vs 36.3 mGy (SD ± 7.7), p < 0.001].

CONCLUSION: Split-bolus CTU immediately after MWA of cT1 RCC offers higher image quality, improved opacification/distention of the collecting system and renal parenchymal enhancement at a lower radiation dose.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Tannenbaum, Lubner, Mithqal, et al. Split-bolus CT urography after microwave ablation of renal cell carcinoma improves image quality and reduces radiation exposure. Abdom Radiol (NY). 2022. PMID: 35238963. doi:10.1007/s00261-022-03448-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。