深度学习图像重建提升腹部增强双能CT图像质量
本研究纳入40例腹部增强双能CT患者,对比混合迭代重建(ASiR-V50%)与深度学习图像重建(DLIR-M、DLIR-H)对虚拟单能40、50、70 keV及碘密度图图像质量的影响。结果显示DLIR显著降低图像噪声、提高门静脉CNR及血管和病灶清晰度,DLIR-H与DLIR-M均优于混合迭代重建。
要点
- DLIR可显著降低腹部双能CT虚拟单能图和碘密度图的图像噪声(p<0.0001)。
- DLIR-H和DLIR-M的门静脉CNR及血管、总体图像质量评分均显著高于混合迭代重建(p<0.05)。
- 各能级虚拟单能图上DLIR-M和DLIR-H的病灶清晰度评分均显著高于混合迭代重建(p≤0.001)。
核心结论
- 与混合迭代重建相比,DLIR可改善腹部增强双能CT虚拟单能图和碘密度图的血管清晰度、CNR及病灶清晰度。
研究设计与样本
- 研究纳入40例接受腹部增强双能CT的患者,采用混合迭代重建(ASiR-V50%)及DLIR中、高强度水平(DLIR-M、DLIR-H)重建虚拟单能40、50、70 keV和碘密度图像;以肝实质衰减标准差作为图像噪声,计算门静脉期门静脉CNR,并对血管清晰度和总体图像质量按1(差)至5(优)评分,对47个腹部实性病灶的病灶清晰度按0(最佳)至-4(明显较差)评分。
关键影像表现/征象
- DLIR较混合迭代重建显著降低虚拟单能40、50、70 keV及碘密度图像的图像噪声(p<0.0001)。
- DLIR-H和DLIR-M的门静脉CNR显著高于混合迭代重建(p<0.0001)。
- DLIR-H和DLIR-M的血管清晰度及总体图像质量评分显著高于混合迭代重建(p<0.05)。
- 各能级虚拟单能图上DLIR-M和DLIR-H的病灶清晰度评分显著高于混合迭代重建(p≤0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the usefulness of deep learning image reconstruction (DLIR) to improve the image quality of dual-energy computed tomography (DECT) of the abdomen, compared to hybrid iterative reconstruction (IR).
METHODS: This study included 40 patients who underwent contrast-enhanced DECT of the abdomen. Virtual monochromatic 40-, 50-, and 70-keV and iodine density images were reconstructed using three reconstruction algorithms, including hybrid IR (ASiR-V50%) and DLIR (TrueFidelity) at medium- and high-strength level (DLIR-M and DLIR-H, respectively). The standard deviation of attenuation in liver parenchyma was measured as image noise. The contrast-to-noise ratio (CNR) for the portal vein on portal venous phase CT was calculated. The vessel conspicuity and overall image quality were graded on a 5-point scale ranging from 1 (poor) to 5 (excellent). The comparative scale of lesion conspicuity in 47 abdominal solid lesions was evaluated on a 5-point scale ranging from 0 (best) to -4 (markedly inferior).
RESULTS: The image noise of virtual monochromatic 40-, 50 -, and 70-keV and iodine density images was significantly decreased by DLIR compared to hybrid IR (p < 0.0001). The CNR was significantly higher in DLIR-H and DLIR-M than in hybrid IR (p < 0.0001). The vessel conspicuity and overall image quality scores were also significantly greater in DLIR-H and DLIR-M than in hybrid IR (p < 0.05). The lesion conspicuity scores for DLIR-M and DLIR-H were significantly higher than those for hybrid IR in the virtual monochromatic image of all energy levels (p ≤ 0.001).
CONCLUSIONS: DLIR improves vessel conspicuity, CNR, and lesion conspicuity of virtual monochromatic and iodine density images in abdominal contrast-enhanced DECT, compared to hybrid IR.
KEY POINTS: • Deep learning image reconstruction (DLIR) is useful for reducing image noise and improving the CNR of visual monochromatic 40-, 50-, and 70-keV images in dual-energy CT. • DLIR can improve lesion conspicuity of abdominal solid lesions on virtual monochromatic images compared to hybrid iterative reconstruction. • DLIR can also be applied to iodine density maps and significantly improves their image quality.
引用
- Sato, Ichikawa, Domae, et al. Deep learning image reconstruction for improving image quality of contrast-enhanced dual-energy CT in abdomen. Eur Radiol. 2022. PMID: 35238970. doi:10.1007/s00330-022-08647-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。