文献速递骨肌儿科影像技术与安全US

椎间盘与特发性脊柱侧凸的超声剪切波弹性成像:一项系统综述

Ultrasound Shear Wave Elastography of the Intervertebral Disc and Idiopathic Scoliosis: A Systematic Review.
PubMed 文献 · Ultrasound Med Biol · 2022-02-26

该系统综述按PRISMA指南检索PubMed和Embase,纳入7篇文章,用AXIS工具评估质量。3项动物离体研究报告剪切波速度与椎间盘力学特性呈中度至良好相关(r=0.45-0.81),3项研究报告操作者内ICC 0.94-0.99、操作者间ICC 0.97-0.98。2项临床研究报告脊柱侧凸患者椎间盘剪切波速度显著高于健康对照,但椎间盘力学特性与剪切波速度的确切相关性仍不清楚。

要点

  • 剪切波速度与椎间盘力学特性呈中度至良好相关(r=0.45-0.81,动物离体研究)。
  • 操作者内重复性ICC 0.94-0.99,操作者间可重复性ICC 0.97-0.98。
  • 脊柱侧凸患者椎间盘剪切波速度显著高于健康对照,侧凸弯内和弯外椎间盘均如此。

核心结论

  • 剪切波弹性成像在评估椎间盘力学特性方面似乎可靠;尽管其有潜力区分无症状与病理椎间盘,但椎间盘力学特性与剪切波速度的确切相关性仍不清楚。

研究设计与样本

  • 系统综述,按PRISMA指南实施,检索PubMed和Embase,采用AXIS工具评估研究质量,共纳入7篇文章。

诊断标准与关键数值

  • 剪切波速度与椎间盘力学特性的相关系数r=0.45-0.81(动物离体研究)。
  • 操作者内重复性ICC 0.94-0.99,操作者间可重复性ICC 0.97-0.98。
  • 脊柱侧凸患者椎间盘剪切波速度显著高于健康对照,侧凸弯内和弯外椎间盘均如此。

局限性

  • 椎间盘力学特性与剪切波速度的确切相关性仍不清楚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Ultrasound shear wave elastography is a radiation-free and low-cost technique for evaluating the mechanical properties of different tissues. This study systematically reviewed all relevant literature on shear wave elastography of the intervertebral disc. The purpose was twofold: first, to determine the validity of the elastography method, that is, the correlation between elastographically measured shear wave speed and disc mechanical properties, and inter-/intra-operator reliability; and second, to explore if disc elastography is potentially useful in identifying children at risk for idiopathic scoliosis. This systematic review was performed according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyses) guidelines. A comprehensive search was performed in PubMed and Embase, and study quality was assessed using the AXIS (Appraisal Tool for Cross-sectional Studies) critical appraisal instrument. Seven articles were included. Three animal ex vivo studies reported moderate-to-good correlations between shear wave speed and disc mechanical properties (r = 0.45-0.81). Three studies reported high intra-operator repeatability (intra-class correlation coefficient [ICC] 0.94-0.99) and inter-operator reproducibility (ICC 0.97-0.98). Four clinical studies measured shear wave speed in asymptomatic children. Two studies reported significantly higher shear wave speeds in scoliosis patients compared with healthy controls, measured in discs both inside and outside the scoliotic curve. In conclusion, shear wave elastography appears reliable in assessing intervertebral disc mechanical characteristics. Despite its promising capabilities to distinguish patients with asymptomatic from those with pathological discs, the exact correlation between disc mechanical properties and shear wave speed remains unclear.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. de Reuver, Moens, Kruyt, et al. Ultrasound Shear Wave Elastography of the Intervertebral Disc and Idiopathic Scoliosis: A Systematic Review. Ultrasound Med Biol. 2022. PMID: 35232608. doi:10.1016/j.ultrasmedbio.2022.01.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。