文献速递乳腺CT

为相衬断层成像设计乳腺支撑装置:为临床试验做准备

Designing a breast support device for phase contrast tomographic imaging: getting ready for a clinical trial.
PubMed 文献 · Br J Radiol · 2022-03-17

研究招募27名参与者试用模拟相衬成像中的乳腺支撑系统,包括俯卧于成像台并佩戴装置。摄影测量分析显示文胸罩杯体积与俯卧位测量体积、最佳贴合单杯固定器体积与俯卧位测量体积均呈正相关。所有参与者表示台面和乳腺支撑装置舒适并愿意继续参与试验,但需重新设计以便未来试验中快速简便地安装。

要点

  • 摄影测量显示文胸罩杯体积与俯卧位测量体积呈显著正相关(p < 0.001)。
  • 最佳贴合单杯固定器体积与俯卧位测量体积呈显著正相关(p < 0.005)。
  • 两种固定器在主观舒适度和静止固定方面均适用,但需重新设计以便快速安装。

核心结论

  • 所有参与者表示台面和乳腺支撑装置舒适,并愿意继续参与试验;相衬断层成像是一种新兴乳腺成像方式,国际临床试验正在启动。

研究设计与样本

  • 27名参与者被招募试用模拟相衬成像期间的乳腺支撑系统,包括俯卧于成像台并佩戴装置;所有参与者试用单杯设计,其中14名参与者还试用带吸引固定器的双杯设计,并完成一系列问卷以了解主观舒适度。

诊断标准与关键数值

  • 摄影测量显示文胸罩杯体积与俯卧位测量体积之间呈显著正相关(p < 0.001)。
  • 最佳贴合单杯固定器体积与俯卧位测量体积之间呈显著正相关(p < 0.005)。

临床应用与阅片要点

  • 两种固定器在主观舒适度和静止固定方面均适用。
  • 未来试验中需重新设计以允许快速、简便地安装,届时将旋转通过辐射束。
  • 必要时轻度吸引耐受良好。

局限性

  • 原文指出,未来试验中需要重新设计以允许快速、简便地安装,届时将旋转通过辐射束。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To design a device that can support the breast during phase-contrast tomography, and characterise its fit parameterisation and comfort rating.

METHODS: 27 participants were recruited to trial a system for breast support during simulated phase contrast imaging, including being positioned on a prone imaging table while wearing the device. Participants underwent a photogrammetry analysis to establish the geometric parameterisations. All participants trialled a single-cup design while 14 participants also trialled a double-cup with suction holder and all completed a series of questionnaires to understand subjective comfort.

RESULTS: Photogrammetry revealed significant positive correlations between bra cup volume and measured prone volume (p < 0.001), and between "best fit" single-cup holder volume and measured prone volume (p < 0.005). Both holders were suitable devices in terms of subjective comfort and immobilisation while stationary. However, some re-engineering to allow for quick, easy fitting in future trials where rotation through the radiation beam will occur is necessary. Light suction was well-tolerated when required.

CONCLUSION: All participants indicated the table and breast support devices were comfortable, and they would continue in the trial.

ADVANCES IN KNOWLEDGE: Phase contrast tomography is an emerging breast imaging modality and clinical trials are commencing internationally. This paper describes the biomedical engineering designs, in parallel with optimal imaging, that are necessary to measure breast volume so that adequate breast support can be achieved. Breast support devices have implications for comfort, motion correction and maximising breast tissue visualisation.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Dimmock, McKinley, Massey, et al. Designing a breast support device for phase contrast tomographic imaging: getting ready for a clinical trial. Br J Radiol. 2022. PMID: 35230134. doi:10.1259/bjr.20211243

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。