文献速递乳腺乳腺X线

合成C-View™与智能2D™乳腺摄影的乳腺密度评估比较

Comparison of breast density assessments between synthesized C-View™ & intelligent 2D™ mammography.
PubMed 文献 · Br J Radiol · 2022-03-08

回顾性比较67例女性在C-View与智能2D两种合成乳腺摄影上的乳腺密度评估,两次检查平均间隔13.3个月。临床BI-RADS密度及Volpara自动密度指标(密度分级、乳腺体积、致密体积、体积密度百分比)均无显著差异。作者认为两种合成版本密度评估无显著差异,密度赋值影响风险分层和辅助筛查建议。

要点

  • C-View与智能2D两种合成乳腺摄影的BI-RADS乳腺密度无显著差异(p=0.74)。
  • Volpara自动密度分级、乳腺体积、致密体积及体积密度百分比均无显著差异。
  • 密度赋值影响风险分层与辅助筛查建议,两版本密度估计无差异具有意义。

核心结论

  • 两种合成乳腺摄影版本(C-View与智能2D)在临床和自动乳腺密度评估上无显著差异。

研究设计与样本

  • 回顾性研究,纳入2017年3月至2019年12月间67例女性,先后接受C-View数字乳腺断层摄影和智能2D数字乳腺断层摄影,两次检查平均间隔13.3个月。

诊断标准与关键数值

  • 临床BI-RADS乳腺密度在两种合成重建间无差异(p=0.74)。
  • Volpara平均密度分级无差异(p=0.71)。
  • Volpara平均乳腺体积无差异(p=0.48)。
  • Volpara平均致密体积无差异(p=0.43)。
  • Volpara平均体积密度百分比无差异(p=0.12)。

临床应用与阅片要点

  • 作者指出密度估计在两种合成重建间无差异很重要,因为密度赋值影响风险分层和辅助筛查建议。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare breast density assessments between C-View™ and Intelligent 2D™, different generations of synthesized mammography (SM) from Hologic.

METHODS: In this retrospective study, we identified a subset of females between March 2017 and December 2019 who underwent screening digital breast tomosynthesis (DBT) with C-View followed by DBT with Intelligent 2D. Clinical Breast Imaging Reporting and Database System breast density was obtained along with volumetric breast density measures (including density grade, breast volume, percentage volumetric density, dense volume) using VolparaTM. Differences in density measures by type of synthesized image were calculated using the pairwise t-test or McNemar's test, as appropriate.

RESULTS: 67 patients (avg age 62.7; range 40-84) were included with an average of 13.3 months between the two exams. No difference was found in Breast Imaging Reporting and Database System density between the SM reconstructions (p = 0.74). Similarly, there was no difference in VolparaTM mean density grade (p = 0.71), mean breast volume (p = 0.48), mean dense volume (p = 0.43) or mean percent volumetric density (p = 0.12) between the exams.

CONCLUSION: We found no significant differences in clinical and automated breast density assessments between these two versions of SM.

ADVANCES IN KNOWLEDGE: Lack of differences in density estimates between the two SM reconstructions is important as density assignment impacts risk stratification and adjunct screening recommendations.