40 keV下深度学习图像重建降低胸腹盆双能CT的辐射与碘剂量

Radiation and iodine dose reduced thoraco-abdomino-pelvic dual-energy CT at 40 keV reconstructed with deep learning image reconstruction.
PubMed 文献 · Br J Radiol · 2022-03-04

前瞻性纳入111例受试者,52例接受标准剂量单能CT与标准碘剂量(600 mgI/kg,SD组),59例接受低剂量双能CT与减量碘剂量(300 mgI/kg,双低剂量DLD组),DLD组在40 keV下用高强度DLIR重建。DLD组CTDIvol中位数4 mGy、碘重量中位数16 g均低于SD组(10 mGy、35 g,P均<0.001),诊断图像质量获得率SD组100%(52/52) vs DLD组95%(56/59)。

要点

  • DLD组CTDIvol中位数4 mGy(IQR 4-5 mGy)低于SD组10 mGy(IQR 9-13 mGy),P<0.001。
  • DLD组碘重量中位数16 g(IQR 14-18 g)低于SD组35 g(IQR 31-38 g),P<0.001。
  • 诊断图像质量获得率SD组100%(52/52) vs DLD组95%(56/59)。

核心结论

  • 40 keV虚拟单能图像结合DLIR重建可在维持诊断图像质量的同时实现辐射剂量和碘剂量减半。

研究设计与样本

  • 前瞻性研究,111例受试者行胸腹盆CT;52例接受标准剂量单能CT与标准碘剂量(600 mgI/kg,SD组),59例接受低剂量双能CT与减量碘剂量(300 mgI/kg,DLD组);SD组用混合迭代重建,DLD组用高强度DLIR在40 keV重建;两名放射科医师测量CT值及背景噪声,另两名放射科医师用5分法评估诊断可接受性;两组比较用Mann-Whitney U检验。

关键影像表现/征象

  • DLD组所有解剖结构(降主动脉、腹主动脉、门静脉、肝静脉、下腔静脉、肝、胰、脾、肾)CT值及背景噪声均高于SD组(P均<0.001)。

诊断标准与关键数值

  • 诊断图像质量获得率SD组100%(52/52) vs DLD组95%(56/59)。
  • CTDIvol中位数SD组10 mGy(IQR 9-13 mGy) vs DLD组4 mGy(IQR 4-5 mGy),P<0.001。
  • 碘重量中位数SD组35 g(IQR 31-38 g) vs DLD组16 g(IQR 14-18 g),P<0.001。
  • 诊断可接受性采用5分法评估。

临床应用与阅片要点

  • DLD组所有解剖结构CT值及背景噪声均高于SD组(P均<0.001),阅片时需注意40 keV下图像噪声与CT值的变化。
  • DLD组诊断图像质量获得率为95%(56/59),低于SD组的100%(52/52)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the feasibility of a simultaneous reduction of radiation and iodine doses in dual-energy thoraco-abdomino-pelvic CT reconstructed with deep learning image reconstruction (DLIR).

METHODS: Thoraco-abdomino-pelvic CT was prospectively performed in 111 participants; 52 participants underwent a standard-dose single-energy CT with a standard iodine dose (600 mgI/kg; SD group), while 59 underwent a low-dose dual-energy CT with a reduced iodine dose [300 mgI/kg; double low-dose (DLD) group]. CT data were reconstructed with a hybrid iterative reconstruction in the SD group and a high-strength level of DLIR at 40 keV in the DLD group. Two radiologists measured the CT numbers of the descending and abdominal aorta, portal vein, hepatic vein, inferior vena cava, liver, pancreas, spleen, and kidney, and background noise. Two other radiologists assessed diagnostic acceptability using a 5-point scale. The CT dose-index volume (CTDIvol), iodine weight, CT numbers of anatomical structures, background noise, and diagnostic acceptability were compared between the two groups using Mann-Whitney U test.

RESULTS: The median CTDIvol [10 mGy; interquartile range (IQR), 9-13 mGy vs 4 mGy; IQR, 4-5 mGy] and median iodine weight (35 g; IQR, 31-38 g vs 16 g; IQR, 14-18 g) were lower in the DLD group than in the SD group (p < 0.001 for each). The CT numbers of all anatomical structures and background noise were higher in the DLD group than in the SD group (p < 0.001 for all). The diagnostic image quality was obtained in 100% (52/52) of participants in the SD group and 95% (56/59) of participants in the DLD group.

CONCLUSION: Virtual monochromatic images at 40 keV reconstructed with DLIR could achieve half doses of radiation and iodine while maintaining diagnostic image quality.

ADVANCES IN KNOWLEDGE: Virtual monochromatic images at 40 keV reconstructed with DLIR algorithm allowed to reduce the doses of radiation and iodine while maintaining diagnostic image quality.

来源:Br J Radiol,查看原文。版权归原作者所有。