文献速递胸部介入CT

肺底结节影像引导经皮穿刺活检:透视CT与锥形束CT的比较

Imaging-guided percutaneous transthoracic needle biopsy of nodules in the lung base: fluoroscopy CT versus cone-beam CT.
PubMed 文献 · Clin Radiol · 2022-02-25

回顾性分析379例肺底结节患者(FCT组228例、CBCT组151例)的经皮穿刺活检数据,技术成功率分别为98.2%和98.7%(p=0.548)。直径>2cm病灶两组诊断准确率、气胸发生率和辐射剂量相近;直径≤2cm病灶诊断准确率相近,但FCT组气胸发生率(66.7% vs 31%,p=0.030)和辐射剂量(19.9±8.4 vs 15.3±5 mSv,p=0.040)均高于CBCT组。

要点

  • 肺底结节PTNB总体技术成功率高,FCT组98.2%、CBCT组98.7%,两组差异无统计学意义(p=0.548)。
  • 直径≤2cm肺底病灶行PTNB时,CBCT引导的气胸发生率(31%)低于FCT引导(66.7%),差异有统计学意义(p=0.030)。
  • 直径≤2cm肺底病灶行PTNB时,CBCT引导的辐射剂量(15.3±5 mSv)低于FCT引导(19.9±8.4 mSv),差异有统计学意义(p=0.040)。

核心结论

  • FCT与CBCT引导的PTNB对肺底较大病灶(>2cm)性能相近;对较小病灶(≤2cm),CBCT在辐射剂量和并发症方面表现更好;放射科医生可根据设备可及性和病灶特征优化技术资源选择。

研究设计与样本

  • 回顾性分析2009年9月至2020年3月共379例肺底结节患者,其中FCT引导组228例、CBCT引导组151例,比较两组PTNB的技术成功、病理诊断、并发症和辐射暴露。

诊断标准与关键数值

  • 总体技术成功率:FCT组98.2% vs CBCT组98.7%,p=0.548。
  • 病灶直径>2cm:FCT组 vs CBCT组诊断准确率95.5% vs 93.64%,气胸发生率31.5% vs 21.3%,辐射剂量16.8±6.1 vs 15.2±4 mSv。
  • 病灶直径≤2cm:FCT组 vs CBCT组诊断准确率92.86% vs 100%,气胸发生率66.7% vs 31%(p=0.030),辐射剂量19.9±8.4 vs 15.3±5 mSv(p=0.040)。

临床应用与阅片要点

  • 对肺底直径>2cm结节,FCT与CBCT引导的PTNB诊断准确率、气胸发生率和辐射剂量相近。
  • 对肺底直径≤2cm结节,CBCT引导的气胸发生率和辐射剂量均低于FCT引导。
  • 放射科医生可根据设备可及性和病灶特征优化技术资源选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To compare the diagnostic performance and safety of fluoroscopy computed tomography (FCT)-guided to cone-beam CT (CBCT)-guided percutaneous transthoracic needle biopsy (PTNB) in patients with nodules in the lung base.

MATERIALS AND METHODS: The clinical data of 379 patients (228 in the FCT group and 151 in the CBCT group) with nodules in the lung base who underwent FCT-guided or CBCT-guided PTNB from September 2009 to March 2020 were analysed retrospectively. Study outcomes included patient demographics, nodule characteristics, technical success, pathological diagnosis, complications, and radiation exposure.

RESULTS: PTNB technical success rates were 98.2% in the FCT group and 98.7% in the CBCT group (p=0.548). For larger lesions (>2 cm in diameter), PTNBs under FCT had similar diagnostic accuracy (95.5% versus 93.64%), incidence of pneumothorax (31.5% versus 21.3%) and radiation exposure (16.8 ± 6.1 versus 15.2 ± 4 mSv) compared to those under CBCT guidance. For smaller lesions (≤2 cm in diameter), the diagnostic accuracy was similar (92.86% versus 100%), but there was a higher incidence of pneumothorax (66.7% versus 31%, p=0.030) and more radiation exposure (19.9 ± 8.4 versus 15.3 ± 5 mSv, p=0.040) under FCT guidance than CBCT.

CONCLUSION: PTNBs under FCT and CBCT guidance had similar performance for larger lesions in lung base. CBCT guidance performed better for smaller lesions in terms of radiation dose and complications. Radiologists could optimise the technological resources based on equipment availability and lesion characteristics.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Ren, Zhou, Yan, et al. Imaging-guided percutaneous transthoracic needle biopsy of nodules in the lung base: fluoroscopy CT versus cone-beam CT. Clin Radiol. 2022. PMID: 35227506. doi:10.1016/j.crad.2022.02.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。