中重度羊水过多:与羊水指数对应的最大垂直羊水池截断值
以受试者工作特征曲线约登指数得出的截断值为8 cm,以百分位数法得出为10 cm;采用8.0 cm而非12.0 cm可将中重度羊水过多检出率提高至100%,假阳性率低于5%。
要点
- 孕晚期超声中,最大垂直羊水池≥8.0 cm时应建议进一步测量完整羊水指数。
- 与羊水指数≥30 cm对应的最大垂直羊水池截断值,约登指数法为8 cm,百分位数法为10 cm。
- 采用8.0 cm较12.0 cm可提高中重度羊水过多检出率至100%,假阳性率低于5%。
核心结论
- 采用8.0 cm而非12.0 cm作为最大垂直羊水池截断值,可将中重度羊水过多检出率提高至100%,假阳性率低于5%;使用最大垂直羊水池评估羊水时,发现最大垂直羊水池≥8.0 cm应促使进一步测量完整羊水指数。
诊断标准与关键数值
- 中重度羊水过多定义为羊水指数≥30 cm;测试组中该阈值对应第98.9百分位,对应最大垂直羊水池10 cm(百分位数法);约登指数法计算的中重度羊水过多最大垂直羊水池截断值为8 cm;采用8.0 cm较12.0 cm检出中重度羊水过多提高至100%,假阳性率低于5%。
临床应用与阅片要点
- 对于使用最大垂直羊水池评估羊水的机构,识别出最大垂直羊水池≥8.0 cm时应促使进一步测量完整羊水指数。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Society for Maternal-fetal medicine Consult Series (#46) states "antenatal fetal surveillance is not required for mild idiopathic" polyhydramnios defined as amniotic fluid index (AFI) of 24 cm or a deepest vertical pocket (DVP) between 8 and 11 cm. The objective of this study was to determine the cutoff for DVP which correlates with AFI ≥ 30 cm.
METHODS: This retrospective study of singleton third trimester ultrasounds included a study group randomly divided into test and validation. In the test group, DVP cutoffs correlating with AFI ≥ 30 cm which was used to define moderate-severe polyhydramnios were calculated in two ways, rounded to the nearest whole number: 1) a receiver operating curve and Youden's J statistic (DVP-Youden) and 2) calculation of the DVP percentile that corresponded with AFI of 30 cm (DVP-Percentile). Using the validation group, diagnostic characteristics were DVP-Youden and DVP-Percentile for diagnosis of AFI ≥ 30 cm and were compared against SMFM cutoffs (DVP-SMFM).
RESULTS: Seventy one thousand eight hundred and ninety three ultrasound exams in the 3rd trimester had assessment of AFI and DVP. Moderate-severe polyhydramnios occurred in 286 (1.2%) in test group and 571 (1.2%) in validation group. AFI of 30 cm corresponded to the 98.9th percentile, which in turn correlated to a DVP of 10 cm (DVP-Percentile). The calculated cutoff for moderate-severe polyhydramnios was 8 cm for DVP-Youden.
CONCLUSION: Using 8.0 cm rather than 12.0 cm increased the detection of moderate-severe polyhydramnios to 100% with a false positive rate under 5%. For those utilizing DVP for amniotic fluid evaluation, identification of a DVP ≥ 8.0 cm should prompt further evaluation with complete AFI.
引用
- Qureshey, Bicocca, Chauhan, et al. Moderate-to-Severe Polyhydramnios: Cutoffs for Deepest Vertical Pocket Corresponding to Amniotic Fluid Index. J Ultrasound Med. 2022. PMID: 35225371. doi:10.1002/jum.15970
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。