文献速递心血管胸部CT

应用计算机断层扫描评估右心室长轴应变对经导管主动脉瓣置换术后预后的价值

Computed tomographic assessment of right ventricular long axis strain for prognosis after transcatheter aortic valve replacement.
PubMed 文献 · Eur J Radiol · 2022-02-14

该回顾性研究纳入168例接受经导管主动脉瓣置换术的重度主动脉瓣狭窄患者,利用术前心脏计算机断层扫描血管成像测量右心室长轴应变等右心功能参数,中位随访21个月期间38例(22.6%)死亡,右心室长轴应变是全因死亡的独立预测因子,并可改善STS-PROM的预测效能。

要点

  • 术前CCTA测得的右心室长轴应变>-11.42%与TAVR术后全因死亡风险升高相关(HR 2.86)。
  • 多变量模型中仅右心室长轴应变保持为全因死亡的独立预测因子(HR 2.36)。
  • 右心室长轴应变使STS-PROM的预测效能从c-index 0.637提升至0.700。

核心结论

  • 右心室长轴应变是接受TAVR的重度主动脉瓣狭窄患者全因死亡的独立预测因子。
  • 右心室长轴应变优于三尖瓣环直径和主肺动脉直径等解剖学标志物。
  • 右心室长轴应变可能改善现有风险分层工具的预测效能。

研究设计与样本

  • 回顾性纳入168例接受TAVR的重度主动脉瓣狭窄患者,中位年龄79岁。
  • 利用术前收缩期和舒张期心脏计算机断层扫描血管成像系列评估右心室长轴应变和右心室射血分数等右心功能参数。
  • 同时评估三尖瓣环直径和主肺动脉直径,记录TAVR术后全因死亡。
  • 采用Cox回归分析,结果以风险比和95%置信区间表示。
  • 采用Harrell's c-index评估不同模型效能,似然比检验比较嵌套模型。

诊断标准与关键数值

  • 右心室长轴应变>-11.42%时,全因死亡风险比为2.86(95%CI 1.44-5.67,p=0.003)。
  • 多变量模型中右心室长轴应变的风险比为2.36(95%CI 1.04-5.36,p=0.04)。
  • 右心室长轴应变联合STS-PROM的c-index为0.700,STS-PROM单独为0.637(p=0.01)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the predictive value of right ventricular long axis strain (RV-LAS) derived by cardiac computed tomography angiography (CCTA) for mortality in patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR).

METHODS: We retrospectively included patients with severe AS undergoing TAVR (n = 168, median 79 years). Parameters of RV function including RV-LAS and RV ejection fraction (RVEF) were assessed using pre-procedural systolic and diastolic CCTA series. The tricuspid annulus diameter (TAD) and diameter of the main pulmonary artery (mPA) were also assessed. All-cause mortality was recorded post-TAVR. Cox regression was used and results are presented with hazard ratio (HR) and 95% confidence interval (CI). Harrell's c-index was used to assess the performance of different models and the likelihood ratio test was used to compare nested models.

RESULTS: Thirty-eight deaths (22.6%) occurred over a median follow-up of 21 months. RV-LAS > -11.42% (HR 2.86, 95% CI 1.44-5.67, p = 0.003), LVEF (HR 0.98, 95% CI 0.96-0.996; p = 0.02), TAD (HR 1.05, 95% CI 1.01-1.10, p = 0.02) and mPA diameter (HR 1.09, 95% CI 1.02-1.16, p = 0.01) were associated with mortality on univariable analysis. In a multivariable model, only RV-LAS (HR 2.36, 95% CI 1.04-5.36, p = 0.04) remained as an independent predictor of all-cause mortality. RV-LAS significantly improved the predictive power of the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) (c-index 0.700 vs 0.637; p = 0.01).

CONCLUSION: RV-LAS was an independent predictor of all-cause mortality in patients with severe AS undergoing TAVR, outperformed anatomical markers such as TAD and mPA diameter, and could potentially improve the current risk-stratifying tool.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Aquino, Decker, Schoepf, et al. Computed tomographic assessment of right ventricular long axis strain for prognosis after transcatheter aortic valve replacement. Eur J Radiol. 2022. PMID: 35220197. doi:10.1016/j.ejrad.2022.110212

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。