沙特人群乳腺X线摄影乳腺密度与乳腺癌风险:视觉与自动方法的病例对照研究
该回顾性病例对照研究纳入1140例沙特女性筛查乳腺X线摄影,比较BI-RADS密度分类、视觉模拟量表(VAS)及两种自动方法(Volpara Density™和预测VAS)评估乳腺密度与乳腺癌风险的关联。结果显示高密度与乳腺癌风险强烈相关,放射科医生视觉评估优于自动方法,但自动方法也能显著预测风险。
要点
- BI-RADS最高密度类别 vs 第二类别的OR为6.69(95%CI 2.79-16.06)。
- VAS最高 vs 最低四分位OR=4.78(95%CI 3.01-7.58),为最强预测因子。
- 放射科医生视觉评估密度对病例与对照的区分优于所有自动方法。
核心结论
- 在沙特女性中,乳腺X线摄影密度增高与乳腺癌风险强烈相关;放射科医生视觉评估乳腺密度优于自动方法,但pVAS和Volpara Density™也能基于乳腺密度显著预测乳腺癌风险。
研究设计与样本
- 回顾性病例对照研究,纳入1140例沙特女性筛查乳腺X线摄影(285例病例和855例对照,按年龄和体重指数匹配);在160例病例和480例对照子集中用Volpara Density™和pVAS两种自动方法估计密度;采用条件逻辑回归估计OR。
诊断标准与关键数值
- BI-RADS密度最高类别 vs 第二类别OR=6.69(95%CI 2.79-16.06);VAS最高 vs 最低四分位OR=4.78(95%CI 3.01-7.58);子集中VAS最高 vs 最低四分位OR=7.54(95%CI 3.86-14.74),pVAS(原始图像)OR=5.38(95%CI 2.68-10.77),Volpara Density™ OR=3.55(95%CI 1.86-6.75);VAS匹配一致性指数0.70(95%CI 0.65-0.75),区分病例与对照优于所有其他方法。
临床应用与阅片要点
- 放射科医生视觉评估乳腺密度可作为乳腺癌风险预测的参考,自动方法也可显著预测风险但区分能力低于视觉评估;本研究为采用自动乳腺密度方法进行个性化筛查提供了初步基础。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study aims to establish risk of breast cancer based on breast density among Saudi women and to compare cancer prediction using different breast density methods.
METHODS: 1140 pseudonymised screening mammograms from Saudi females were retrospectively collected. Breast density was assessed using Breast Imaging Reporting and Data System (BI-RADS) density categories and visual analogue scale (VAS) of 285 cases and 855 controls matched on age and body mass index. In a subset of 160 cases and 480 controls density was estimated by two automated methods, Volpara Density™ and predicted VAS (pVAS). Odds ratios (ORs) between the highest and second categories in BI-RADS and Volpara density grades, and highest vs lowest quartiles in VAS, pVAS and Volpara Density™, were estimated using conditional logistic regression.
RESULTS: For BI-RADS, the OR was 6.69 (95% CI 2.79-16.06) in the highest vs second category and OR = 4.78 (95% CI 3.01-7.58) in the highest vs lowest quartile for VAS. In the subset, VAS was the strongest predictor OR = 7.54 (95% CI 3.86-14.74), followed by pVAS using raw images OR = 5.38 (95% CI 2.68-10.77) and Volpara Density ™ OR = 3.55, (95% CI 1.86-6.75) for highest vs lowest quartiles. The matched concordance index for VAS was 0.70 (95% CI 0.65-0.75) demonstrating better discrimination between cases and controls than all other methods.
CONCLUSION: Increased mammographic density was strongly associated with risk of breast cancer among Saudi women. Radiologists' visual assessment of breast density is superior to automated methods. However, pVAS and Volpara Density ™ also significantly predicted breast cancer risk based on breast density.
ADVANCES IN KNOWLEDGE: Our study established an association between breast density and breast cancer in a Saudi population and compared the performance of automated methods. This provides a stepping-stone towards personalised screening using automated breast density methods.
引用
- Aloufi, AlNaeem, Almousa, et al. Mammographic breast density and breast cancer risk in the Saudi population: a case-control study using visual and automated methods. Br J Radiol. 2022. PMID: 35195439. doi:10.1259/bjr.20211197
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。