人工智能迭代重建用于低剂量主动脉CT血管造影的图像质量评估:70 kVp与低对比剂用量的可行性研究

Image quality assessment of artificial intelligence iterative reconstruction for low dose aortic CTA: A feasibility study of 70 kVp and reduced contrast medium volume.
PubMed 文献 · Eur J Radiol · 2022-02-15

前瞻性纳入50例主动脉疾病患者,均行两次以上主动脉CTA随访。首次用标准剂量方案(100 kVp,对比剂0.8 mgL/kg)并行混合迭代重建,第二次用低剂量方案(70 kVp,对比剂0.5 mgL/kg)并行混合迭代重建及人工智能迭代重建。低剂量组有效辐射剂量和对比剂用量较标准剂量组分别降低84.14%和37.08%。人工智能迭代重建图像噪声更低、信噪比和对比噪声比更高,主观评分与标准剂量混合迭代重建图像无显著差异。

要点

  • 低剂量方案(70 kVp、对比剂0.5 mgL/kg)较标准方案(100 kVp、0.8 mgL/kg)辐射剂量降低84.14%、对比剂用量降低37.08%。
  • 人工智能迭代重建较混合迭代重建图像噪声更低、信噪比和对比噪声比更高。
  • 人工智能迭代重建与标准剂量混合迭代重建的主观评分无显著差异。

核心结论

  • 与标准主动脉CTA混合迭代重建相比,人工智能迭代重建算法可在低剂量主动脉CTA中降低辐射剂量和对比剂用量,同时保持图像质量。

研究设计与样本

  • 前瞻性可行性研究,连续纳入50例主动脉疾病患者(平均年龄58±14岁,平均BMI 24.5±4.7 kg/m2),均行至少两次主动脉CTA随访;首次为标准剂量CT(100 kVp,自动mAs,对比剂0.8 mgL/kg)行混合迭代重建,第二次为低剂量CT(70 kVp,自动mAs,对比剂0.5 mgL/kg)行混合迭代重建和人工智能迭代重建;两名盲法放射科医师用5分法主观评分。

关键影像表现/征象

  • 三组重建图像CT值衰减相似(P>0.05)。
  • 低剂量人工智能迭代重建较低剂量混合迭代重建图像噪声更低、信噪比和对比噪声比更高。
  • 低剂量人工智能迭代重建与标准剂量混合迭代重建在四项主观指标上无显著差异(P>0.05)。

诊断标准与关键数值

  • 主观图像质量采用5分法由两名盲法放射科医师评分。
  • 客观分析指标包括CT值衰减、噪声、信噪比和对比噪声比。

临床应用与阅片要点

  • 低剂量主动脉CTA方案(70 kVp、对比剂0.5 mgL/kg)联合人工智能迭代重建可在降低辐射和对比剂用量的同时保持图像质量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the image quality and feasibility of a novel artificial intelligence iterative reconstruction (AIIR) algorithm for aortic computer tomography angiography (CTA) with a low radiation dose and contrast material (CM) dosage protocol in comparison with hybrid iterative reconstruction (HIR) algorithm for standard-of-care aortic CTA.

METHODS: Fifty consecutive patients (mean age 58 ± 14 years, mean BMI 24.5 ± 4.7 kg/m2) with aortic diseases were prospectively enrolled. All patients underwent at least twice follow-up aortic CTA examinations. Standard dose CT (SDCT) was applied in the initial follow-up examination (100 kVp, auto mAs, contrast dose 0.8 mgL/kg), images were reconstructed with HIR (SDCT-HIR). In the second follow-up examination, patients underwent scanning with low dose CT (LDCT) (70 kVp, auto mAs, contrast dose 0.5 mgL/kg), images were reconstructed with HIR (LDCT-HIR) as well as AIIR (LDCT-AIIR). Attenuation values, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured for objective analysis. Subjective image quality was rated by two blinded radiologists using a 5-point scale. The effective radiation dose and CM dosage were also recorded.

RESULTS: The effective radiation dose (1.58 ± 0.17 mSv vs. 9.96 ± 1.05 mSv, P < 0.001) and CM dosage (34.38 ± 5.43 ml vs. 54.64 ± 8.63 ml, P < 0.001) achieved a remarkable reduction of 84.14% and 37.08% in the LDCT compared to the SDCT. The attenuation was similar among the three reconstructed images (P > 0.05). Compared to LDCT-HIR images, LDCT-AIIR showed a lower noise and higher SNR and CNR. For qualitative analysis, there were no significant differences between the LDCT-AIIR and the SDCT-HIR images among four metrics (P > 0.05).

CONCLUSIONS: Compared to standard-of-care aortic CTA with HIR, the application of the AIIR algorithm allows for radiation dose and CM dosage reduction while preserving image quality on low dose aortic CTA.

来源:Eur J Radiol,查看原文。版权归原作者所有。