文献速递腹部MR

钆塞酸二钠增强磁共振成像中多动脉期图像的临床实用性:系统评价与荟萃分析

Clinical usefulness of multiple arterial-phase images in gadoxetate disodium-enhanced magnetic resonance imaging: a systematic review and meta-analysis.
PubMed 文献 · Eur Radiol · 2022-02-22

该系统评价与荟萃分析纳入12篇文章共22项研究,比较钆塞酸二钠增强MRI中多动脉期与单动脉期技术的临床价值。多动脉期组充分动脉期成像百分比为94.8%,高于单动脉期组的78.7%(p<0.01);病灶检出率为83.2%对50.0%(p=0.06)。作者认为多动脉期可能更具临床实用性,但因研究异质性和发表偏倚需进一步研究验证。

要点

  • 多动脉期MRI充分动脉期成像合并百分比94.8%,高于单动脉期78.7%(p<0.01)。
  • 多动脉期MRI病灶检出率83.2%,单动脉期50.0%,差异未达统计学显著(p=0.06)。
  • 多动脉期研究存在显著发表偏倚(p<0.01),单动脉期研究未见(p=0.87)。

核心结论

  • 钆塞酸二钠增强多动脉期MRI可能比单动脉期MRI更具临床实用性,但由于研究异质性和发表偏倚,需进一步研究验证该发现。

研究设计与样本

  • 系统评价与荟萃分析,检索PubMed、EMBASE和Cochrane Library数据库,从772篇文献中纳入12篇文章共22项研究,其中18项研究(10项多动脉期、8项单动脉期)定义充分动脉期成像百分比,4项研究(3项多动脉期、1项单动脉期)定义病灶检出率,采用单比例随机效应荟萃分析计算合并百分比,亚组分析探讨异质性原因,Egger检验评估发表偏倚。

诊断标准与关键数值

  • 多动脉期MRI充分动脉期成像合并百分比94.8%,单动脉期MRI为78.7%,多动脉期高16.1%(p<0.01);多动脉期MRI病灶检出率83.2%,单动脉期MRI为50.0%,多动脉期额外检出33.2%的病灶(p=0.06)。

临床应用与阅片要点

  • 作者认为钆塞酸二钠增强多动脉期MRI可能比单动脉期MRI更具临床实用性,但需进一步研究验证。

局限性

  • 多动脉期MRI研究存在显著发表偏倚(p<0.01),单动脉期研究未发现显著发表偏倚(p=0.87)。
  • 多动脉期研究存在显著异质性,充分动脉期成像的定义、病灶特征和参考标准是影响研究异质性的显著因素(p≤0.02)。
  • 由于研究异质性和发表偏倚,需进一步研究验证该发现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The multiple arterial-phase (AP) technique was introduced for liver MRI, but it is not really known if multiple AP MRI (MA-MRI) improves image quality and lesion detection rate on gadoxetate disodium-enhanced MRI in comparison with single AP MRI (SA-MRI). We aimed to determine the clinical usefulness of MA-MRI in comparison with SA-MRI.

METHODS: Original articles reporting the percentage of adequate AP imaging and the lesion detection rate on gadoxetate disodium-enhanced MA-MRI were identified in PubMed, EMBASE, and Cochrane Library databases. The pooled percentage of adequate AP imaging and lesion detection rate were calculated using random-effects meta-analysis of single proportions. Subgroup analysis was performed to explain causes of study heterogeneity, and publication bias was evaluated using Egger's test.

RESULTS: Of 772 articles screened, 22 studies in 12 articles were included: 18 studies (ten MA-MRI and eight SA-MRI) suitably defined the percentage of adequate AP imaging and four (three MA-MRI and one SA-MRI) defined the lesion detection rate. MA-MRI had 16.1% higher pooled percentage of adequate AP imaging than SA-MRI (94.8% vs. 78.7%, p < 0.01). MA-MRI additionally detected 33.2% of lesions than SA-MRI (83.2% vs. 50.0%, p = 0.06). Substantial study heterogeneity was found in MA-MRI, and the definition of adequate AP imaging, lesion characteristics, and reference standards were significant factors affecting study heterogeneity (p ≤ 0.02). Significant publication bias was found in MA-MRI (p < 0.01) but not in SA-MRI studies (p = 0.87).

CONCLUSIONS: Gadoxetate disodium-enhanced MA-MRI may be more clinically useful than SA-MRI, but further study is necessary to validate this finding because of study heterogeneity and publication bias.

KEY POINTS: • Multiple arterial-phase MRI (MA-MRI) had a 16.1% higher pooled percentage of adequate AP imaging than single arterial-phase MRI (SA-MRI) (94.8% vs. 78.7%, p < 0.01). • MA-MRI additionally detected an extra 33.2% of lesions compared with SA-MRI (83.2% vs. 50.0%, p = 0.06). • Substantial study heterogeneity and significant publication bias were found across MA-MRI studies.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Hong, Choi, Hong, et al. Clinical usefulness of multiple arterial-phase images in gadoxetate disodium-enhanced magnetic resonance imaging: a systematic review and meta-analysis. Eur Radiol. 2022. PMID: 35192009. doi:10.1007/s00330-022-08620-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。