利用术前影像鉴别肝脏黏液性囊肿与单纯性囊肿
研究纳入95例术前诊断为肝囊性病变并接受手术的患者,评估囊肿壁无压迹的分隔征象诊断黏液性囊性肿瘤(MCN)的准确性。该征象敏感度较高(80-87%)但特异度低(48-66%),观察者间一致性仅一般(κ=0.35),单独用于鉴别MCN与单纯性囊肿的临床价值有限。
要点
- 囊肿壁无压迹的分隔征象诊断MCN敏感度80-87%,但特异度仅48-66%。
- 三位放射科医生判断病变为MCN的AUC为0.67-0.79,观察者间一致性一般(κ=0.40)。
- 该征象检出存在观察者间差异,单独用于鉴别MCN与单纯性囊肿的临床价值有限。
核心结论
- 囊肿壁无压迹的分隔征象具有足够敏感度鉴别MCN与单纯性囊肿,但该征象检出存在变异性,单独应用临床价值有限。
研究设计与样本
- 前瞻性维护数据库查询,纳入术前诊断为肝囊性病变并接受手术干预的95例患者,评估术前3个月内横断面影像,由三位对病理不知情的放射科医生独立评估。
关键影像表现/征象
- 囊肿壁无压迹的分隔征象在横断面影像上可见于部分肝囊性病变。
- 病理结果:80例(84%)为单纯性囊肿,15例(16%)为黏液性囊性肿瘤。
诊断标准与关键数值
- 囊肿壁无压迹的分隔征象诊断MCN的敏感度范围为80-87%,特异度范围为48-66%。
- 三位放射科医生判断病变为MCN而非单纯性囊肿的敏感度范围为20-80%,特异度范围为71-91%,AUC为0.67-0.79。
- 观察者间一致性:囊肿壁无压迹分隔征象的百分比一致率为51%,κ=0.35(95%CI 0.22-0.47);判断病变为MCN的百分比一致率为67%,κ=0.40(95%CI 0.25-0.55)。
局限性
- 该征象的检出存在观察者间变异性,单独应用临床价值有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Preoperative radiographic differentiation of mucinous cystic neoplasms (MCN) and simple cysts (SLC) of the liver is challenging. Previous data have demonstrated that the finding of septations arising from the cyst wall without indentation on cross-sectional imaging is associated with MCN. We aim to assess whether this radiographic feature is diagnostic of MCN.
METHODS: A prospectively maintained database was queried for patients with a preoperative diagnosis of a cystic liver lesion who subsequently underwent operative intervention. The feature of septations without indentation of the cyst wall was evaluated on cross-sectional imaging obtained within 3 months of operation. Imaging was independently evaluated by three radiologists blinded to pathology and interobserver agreement was compared to assess the diagnostic accuracy of this feature as well as the overall likelihood of the lesion representing a MCN.
RESULTS: There were 95 patients who met inclusion criteria; 80 (84%) had SLC on pathology, while 15 (16%) had MCN. Presence of septa without indentation of cyst wall had high sensitivity (range 80-87%), but low specificity (range 48-66%). Interobserver percent agreement (PA) was 51% [κ = 0.35 (95% CI 0.22-0.47)]. Sensitivity among the three radiologists ranged between 20 and 80% and specificity between 71 and 91% for the likelihood of the lesion representing MCN versus SLC, with an area under the curve (AUC) of 0.67-0.79; however, interobserver agreement was fair [κ = 0.40 (95% CI 0.25-0.55), PA = 67%].
CONCLUSION: The presence of septations without indentation of cyst wall demonstrates adequate sensitivity to differentiate MCN and SLC. However, there is variability for detection of this feature and therefore, it alone is of limited clinical value.
引用
- McIntyre, Girshman, Goldman, et al. Differentiation of mucinous cysts and simple cysts of the liver using preoperative imaging. Abdom Radiol (NY). 2022. PMID: 35188592. doi:10.1007/s00261-022-03436-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。