自由呼吸质子MRI检出COVID-19幸存者动态通气功能异常
前瞻性研究纳入27例住院COVID-19幸存者(感染至图像采集62.4±8.1天)和12名健康志愿者,行自由呼吸1H MRI并分析常规FD-V与改良mPREFUL动态通气图;幸存者静态FD-V与健康组无显著差异(0.47±0.12 vs 0.42±0.08,p=.233),但mPREFUL显示局部高通气百分比显著增高(23.7%±10.6% vs 13.1%±7.9%,p=.003),且呼吸更深(流量-容积环5375±3978 vs 1688±789,p=.005)。
要点
- 静态FD-V图未能区分COVID-19幸存者与健康人(0.47±0.12 vs 0.42±0.08,p=.233)。
- mPREFUL动态通气图显示幸存者局部高通气百分比显著高于健康志愿者(23.7%±10.6% vs 13.1%±7.9%,p=.003)。
- 幸存者呼吸更深、每呼吸周期总气量更大(62.6±19.3 vs 37.3±9.9,p<.001),动态图较静态图更敏感。
核心结论
- 应用自由呼吸1H MRI动态通气成像发现COVID-19幸存者存在区域动态通气功能异常。
研究设计与样本
- 前瞻性研究,纳入12名健康志愿者和27例住院COVID-19幸存者(感染至图像采集62.4±8.1天),行自由呼吸胸部1H MRI采集,分析常规傅里叶分解通气(FD-V)和全局分数通气(FVGlobal),并开发改良PREFUL(mPREFUL)方法生成动态通气图及参数;采用Student t检验,并行Pearson相关和Bland-Altman分析。
关键影像表现/征象
- 静态FD-V图上COVID-19组与健康组无显著差异(0.47±0.12 vs 0.42±0.08,p=.233);mPREFUL动态通气图显示幸存者存在大量区域高通气区(高通气百分比HVP 23.7%±10.6%),健康志愿者为13.1%±7.9%(p=.003);幸存者流量-容积环更大(5375±3978 vs 1688±789,p=.005),呼吸周期总气量更多(62.6±19.3 vs 37.3±9.9,p<.001)。
诊断标准与关键数值
- mPREFUL与FVGlobal的Pearson相关r=0.74(p<.001),Bland-Altman平均偏倚-0.01;HVP在幸存者23.7%±10.6% vs健康志愿者13.1%±7.9%(p=.003);FD-V值幸存者0.47±0.12 vs健康志愿者0.42±0.08(p=.233)。
临床应用与阅片要点
- 作者认为动态通气图较静态通气图更敏感地区分COVID-19幸存者与健康组(总气量62.6±19.3 vs 37.3±9.9,p<.001;FD-V值0.47±0.12 vs 0.42±0.08,p=.233)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To visualize and quantitatively assess regional lung function of survivors of COVID-19 who were hospitalized using pulmonary free-breathing 1H MRI.
METHODS: A total of 12 healthy volunteers and 27 COVID-19 survivors (62.4 ± 8.1 days between infection and image acquisition) were recruited in this prospective study and performed chest 1H MRI acquisitions with free tidal breathing. Then, conventional Fourier decomposition ventilation (FD-V) and global fractional ventilation (FVGlobal) were analyzed. Besides, a modified PREFUL (mPREFUL) method was developed to adapt to COVID-19 survivors and generate dynamic ventilation maps and parameters. All the ventilation maps and parameters were analyzed using Student's t-test. Pearson's correlation and a Bland-Altman plot between FVGlobal and mPREFUL were analyzed.
RESULTS: There was no significant difference between COVID-19 and healthy groups regarding a static FD-V map (0.47 ± 0.12 vs 0.42 ± 0.08; p = .233). However, mPREFUL demonstrated lots of regional high ventilation areas (high ventilation percentage (HVP): 23.7% ± 10.6%) existed in survivors. This regional heterogeneity (i.e., HVP) in survivors was significantly higher than in healthy volunteers (p = .003). The survivors breathed deeper (flow-volume loop: 5375 ± 3978 vs 1688 ± 789; p = .005), and breathed more air in respiratory cycle (total amount: 62.6 ± 19.3 vs 37.3 ± 9.9; p < .001). Besides, mPREFUL showed both good Pearson's correlation (r = 0.74; p < .001) and Bland-Altman consistency (mean bias = -0.01) with FVGlobal.
CONCLUSIONS: Dynamic ventilation imaging using pulmonary free-breathing 1H MRI found regional abnormity of dynamic ventilation function in COVID-19 survivors.
KEY POINTS: • Pulmonary free-breathing1H MRI was used to visualize and quantitatively assess regional lung ventilation function of COVID-19 survivors. • Dynamic ventilation maps generated from 1H MRI were more sensitive to distinguish the COVID-19 and healthy groups (total air amount: 62.6 ± 19.3 vs 37.3 ± 9.9; p < .001), compared with static ventilation maps (FD-V value: 0.47 ± 0.12 vs 0.42 ± 0.08; p = .233). • COVID-19 survivors had larger regional heterogeneity (high ventilation percentage: 23.7% ± 10.6% vs 13.1% ± 7.9%; p = .003), and breathed deeper (flow-volume loop: 5375 ± 3978 vs 1688 ± 789; p = .005) than healthy volunteers.
引用
- Wang, Li, Xiao, et al. Abnormal dynamic ventilation function of COVID-19 survivors detected by pulmonary free-breathing proton MRI. Eur Radiol. 2022. PMID: 35184219. doi:10.1007/s00330-022-08605-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。