文献速递神经CT

非增强CT与CT灌注成像对溶栓治疗急性缺血性卒中预后的评估

Prognosis with non-contrast CT and CT Perfusion imaging in thrombolysis-treated acute ischemic stroke.
PubMed 文献 · Eur J Radiol · 2022-02-15

回顾性纳入2019年1月至2020年5月75例溶栓前接受NCCT和CTP的急性缺血性卒中患者,35例(46.7%)预后良好;自动与人工ASPECTS和CTP-ASPECTS一致性为中等至高度,梗死核心体积是独立预后因素,多因素模型AUC为0.768(95%CI 0.666-0.870)。

要点

  • 自动ASPECTS与CTP-ASPECTS达到高度一致(κ=0.685),可用于快速评估。
  • 梗死核心体积是多因素分析中唯一独立预后因素。
  • ASPECTS、高密度血管征、梗死核心体积和错配比与功能预后单因素相关。

核心结论

  • 自动ASPECTS与参考CTP-ASPECTS达到高度一致,综合CT评估可能有助于静脉溶栓后急性缺血性卒中的预后判断。

研究设计与样本

  • 回顾性研究纳入2019年1月至2020年5月75例溶栓治疗的急性缺血性卒中患者,治疗前接受NCCT和CT灌注成像。
  • 由一名放射科医生、一名资深神经放射科医生和一名神经科医生盲法判读NCCT的ASPECTS,原型软件生成自动ASPECTS。
  • 另一名独立放射科医生判定高密度血管征和CTP-ASPECTS,以3个月改良Rankin量表≤2分定义功能预后良好。

关键影像表现/征象

  • 高密度血管征(HDVS)在基线NCCT上判定,与功能预后单因素相关。
  • NCCT ASPECTS、梗死核心体积和错配比与功能预后单因素相关,梗死核心体积在多因素分析中为独立预后因素。

诊断标准与关键数值

  • 自动ASPECTS与CTP-ASPECTS的平方加权κ值为0.685,放射科医生为0.778,神经放射科医生为0.830,神经科医生为0.313。
  • 多因素模型预测功能预后的AUC为0.768(95%CI 0.666-0.870)。

临床应用与阅片要点

  • 自动ASPECTS与CTP-ASPECTS一致性达高度,可作为NCCT快速评估的参考。
  • 结合NCCT的ASPECTS、高密度血管征与CTP的梗死核心体积、错配比综合评估,可能有助于溶栓预后判断。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The Alberta Stroke Program Early CT Score (ASPECTS) and hyperdense vessel sign (HDVS) on baseline non-contrast CT (NCCT) may benefit prognosis of acute ischemic stroke (AIS). We aimed to investigate the agreement of ASPECTS between automated and manual interpretations, and further understand the roles of NCCT and CT Perfusion (CTP) in prognosis.

MATERIALS AND METHODS: From January 2019 to May 2020, thrombolysis-treated AIS patients undergoing NCCT and Perfusion imaging before treatment were retrospectively reviewed. A radiologist, a senior neuroradiologist and a neurologist blindly interpreted ASPECTS from NCCT images and a prototypical software produced automated results. Another independent radiologist determined presence of HDVS and CTP-ASPECTS. Three-month modified Rankin scale (mRS) ≤ 2 indicated good functional outcome. NCCT ASPECTS were compared against CTP-ASPECTS using squared weighted kappa. Univariable, multivariable and receiver operating characteristics (ROC) analysis were conducted to evaluate the prognostic value of clinical risk factors, NCCT and CTP findings.

RESULTS: Seventy-five patients were included in this study, of whom 35 (46.7%) presented favorable outcome. Fair to substantial agreement with CTP-ASPECTS was witnessed for automated and manual interpretations (0.685, automated; 0.778, radiologist; 0.830, neuroradiologist; 0.313, neurologist). ASPECTS, HDVS, infarct core volume and mismatch ratio were univariably related to functional outcome, and infarct core volume remained as an independent prognostic factor in the multivariable analysis. The multivariable model achieved an area under ROC (AUC) of 0.768 (95% CI, 0.666-0.870).

CONCLUSIONS: Automated ASPECTS achieves substantial agreement with reference CTP-ASPECTS, and comprehensive CT assessment may benefit AIS prognosis after intravenous thrombolysis.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Chen, Lin, Zhang, et al. Prognosis with non-contrast CT and CT Perfusion imaging in thrombolysis-treated acute ischemic stroke. Eur J Radiol. 2022. PMID: 35183901. doi:10.1016/j.ejrad.2022.110217

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。