文献速递乳腺乳腺X线US

磁种子定位不可触及乳腺病灶:单中心经验

Magseed localisation of non-palpable breast lesions: experience from a single centre.
PubMed 文献 · Clin Radiol · 2022-02-14

本研究前瞻性分析接受磁种子(Magseed)定位(MSL)的患者结局,并回顾性比较MSL与既往导丝定位(WGL)的再切除率,以检验MSL可能降低再切除率的假设。2017年12月至2019年12月共255例患者接受MSL,98%(n=250)首次尝试即成功,术中100%识别Magseed并完成手术切除。再切除率从2016/2017年的18.9%降至2018/2019年的11.6%(p=0.098)。

要点

  • MSL首次尝试成功率98%(250/255),术中Magseed识别率100%。
  • 再切除率从2016/2017年18.9%降至2018/2019年11.6%,p=0.098。
  • 作者认为MSL安全有效且定位准确性高,再切除率降低为潜在获益,需进一步研究。

核心结论

  • Magseed定位是安全有效的乳腺病灶定位方法,具有高准确性;引入MSL后再切除率降低为潜在获益,需进一步研究。

研究设计与样本

  • 前瞻性分析2017年12月至2019年12月单乳腺单元接受MSL的患者,并回顾性收集2016年1月至2019年12月接受定位乳腺手术的患者以比较再切除率;MSL于2017年12月在University Hospital Crosshouse开始,期间未改变其他影像或外科实践。

诊断标准与关键数值

  • 255例接受MSL手术的患者中,98%(n=250)首次尝试即成功放置Magseed。
  • 术中100%患者识别Magseed并完成手术切除。
  • 再切除率从2016/2017年的18.9%降至2018/2019年的11.6%(p=0.098)。

临床应用与阅片要点

  • 作者认为MSL是安全有效的乳腺病灶定位方法,具有高准确性。
  • 作者认为引入MSL后再切除率降低为潜在获益,需进一步研究。

局限性

  • 再切除率降低为潜在获益,需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To prospectively analyse patients undergoing magnetic seed (Magseed) localisation (MSL) to evaluate the outcome, and to retrospectively compare re-excision rates for MSL with previous wire-guided localisation (WGL) to assess the hypothesis that the introduction of MSL may lead to a lower re-excision rate.

MATERIALS AND METHODS: MSL commenced at University Hospital Crosshouse in December 2017. No other changes were made to radiological or surgical practice during this time. Data were collected prospectively on all patients undergoing MSL between December 2017 and December 2019, in a single breast unit. Data were gathered retrospectively on patients who had undergone localised breast procedures between January 2016 and December 2019 for comparison of re-excision rates.

RESULTS: Two hundred and fifty-five patients underwent MSL surgery between December 2017 and December 2019. Of those, 98% (n=250) patients underwent successful MSL at the first attempt. The Magseed was identified intraoperatively in 100% patients and surgical excision was performed. The re-excision rate reduced from 18.9% in 2016/2017, to 11.6% in 2018/2019 (p=0.098).

CONCLUSION: In conclusion, Magseed localisation has proved to be a safe and effective way of localising breast lesions, with the advantage of high accuracy. The reduction in re-excision rates at University Hospital Crosshouse with the introduction of Magseed® localisation is a potential benefit, which requires further study.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Ross, Elgammal, Reid, et al. Magseed localisation of non-palpable breast lesions: experience from a single centre. Clin Radiol. 2022. PMID: 35177228. doi:10.1016/j.crad.2022.01.034

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。