基于混合深度学习去噪方法用于垂体MRI压缩感知:与传统小波去噪方法的比较
本回顾性研究纳入28例连续患者,对欠采样垂体T2WI分别采用传统小波去噪法与混合小波+深度学习重建(DLR)法在五个去噪水平重建。混合DLR法使脑脊液SNR随去噪水平递增而升高,小波法在较高去噪水平下SNR不升高;两种方法的主效应及交互作用均有统计学意义(p < 0.001)。混合DLR法图像质量优于单独小波法,尤其在较高去噪水平。
要点
- 混合DLR法重建的垂体T2WI图像质量优于传统小波法,尤其在高去噪水平。
- 混合DLR法脑脊液SNR随去噪水平升高而递增,小波法在较高去噪水平SNR不升高。
- 两种去噪方法及去噪水平的主效应和交互作用均有统计学意义(p < 0.001)。
核心结论
- 混合DLR法在压缩感知垂体T2WI中可提供比单独小波法更高的图像质量,尤其在较高去噪水平。
研究设计与样本
- 回顾性研究,纳入28例连续患者,行欠采样垂体T2WI;图像采用传统小波去噪法或小波与DLR结合的混合DLR法在五个去噪水平重建;由两名委员会认证放射科医师进行定性评估;采用稳健的双因素重复测量方差分析。
诊断标准与关键数值
- 使用混合DLR法时,脑脊液SNR随去噪水平升高而逐渐增加;使用小波法时,脑脊液、下丘脑和垂体的SNR在较高去噪水平下不增加。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to evaluate the efficacy of a combined wavelet and deep-learning reconstruction (DLR) method for under-sampled pituitary MRI.
METHODS: This retrospective study included 28 consecutive patients who underwent under-sampled pituitary T2-weighted images (T2WI). Images were reconstructed using either the conventional wavelet denoising method (wavelet method) or the wavelet and DLR methods combined (hybrid DLR method) at five denoising levels. The signal-to-noise ratio (SNR) of the CSF, hypothalamic, and pituitary images and the contrast between structures were compared between the two image types. Noise quality, contrast, sharpness, artifacts, and overall image quality were evaluated by two board-certified radiologists. The quantitative and the qualitative analyses were performed with robust two-way repeated analyses of variance.
RESULTS: Using the hybrid DLR method, the SNR of the CSF progressively increased as denoising levels increased. By contrast, with the wavelet method, the SNR of the CSF, hypothalamus, and pituitary did not increase at higher denoising levels. There was a significant main effect of denoising methods (p < 0.001) and denoising levels (p < 0.001), and an interaction between denoising methods and denoising levels (p < 0.001). For all five qualitative scores, there was a significant main effect of denoising methods (p < 0.001) and an interaction between denoising methods and denoising levels (p < 0.001).
CONCLUSIONS: The hybrid DLR method can provide higher image quality for T2WI of the pituitary with compressed sensing (CS) than the wavelet method alone, especially at higher denoising levels.
KEY POINTS: • The signal-to-noise ratios of cerebrospinal fluid progressively increased with the hybrid DLR method, with an increase in the denoising level for cerebrospinal fluid in pituitary T2WI with CS. • The signal-to-noise ratios of cerebrospinal fluid using the conventional wavelet method did not increase at higher denoising levels. • All qualitative scores of hybrid deep-learning reconstructions at all denoising levels were higher than those for the wavelet denoising method.
引用
- Uetani, Nakaura, Kitajima, et al. Hybrid deep-learning-based denoising method for compressed sensing in pituitary MRI: comparison with the conventional wavelet-based denoising method. Eur Radiol. 2022. PMID: 35169896. doi:10.1007/s00330-022-08552-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。