文献速递乳腺乳腺X线

获取数字乳腺断层合成(DBT)点压视图对评估DBT不确定发现的影响

Impact of Obtaining a Digital Breast Tomosynthesis (DBT) Spot Compression View on Assessment of Equivocal DBT Findings.
PubMed 文献 · AJR Am J Roentgenol · 2022-02-16

这项回顾性研究纳入102例因DBT不确定发现而加做DBT点压视图的女性,比较标准DBT与加做点压视图后的BI-RADS分类及诊断效能。结果显示点压视图提高了阅片者内和阅片者间一致性,并显著提高准确度和特异度(主要归因于特异度改善),点压视图的补充辐射剂量略高于标准DBT视图。

要点

  • DBT点压视图可提高对不确定病灶的BI-RADS分类一致性和诊断准确度。
  • 准确度提升主要来自特异度提高,三名阅片者特异度均显著增加。
  • 点压视图补充剂量(1.97 mGy)略高于标准DBT视图(1.78-1.81 mGy)。

核心结论

  • 使用DBT点压视图可提高阅片者内一致性、阅片者间一致性和诊断准确度(主要因特异度改善);点压视图的补充剂量略高于标准DBT视图。

研究设计与样本

  • 回顾性研究,纳入102名女性(平均年龄60岁),在2018年12月14日至2018年12月18日期间行DBT检查,由两名乳腺影像专科培训放射科医师和一名乳腺影像研究员独立阅片,以组织学和至少1年影像随访为参考标准。

关键影像表现/征象

  • DBT点压视图是在DBT采集过程中使用小压迫板获取的附加视图。

诊断标准与关键数值

  • BI-RADS 2类和3类视为阴性,4A类及以上视为阳性。
  • 阅片者内一致性kappa从0.43(无点压视图)升至0.72(有点压视图)。
  • 阅片者间一致性kappa从0.21(无点压视图)升至0.45(有点压视图)。
  • 与标准DBT视图相比,DBT点压视图使三名阅片者的准确度分别从75%升至90%、74%升至94%、72%升至94%(均显著提高)。
  • 与标准DBT视图相比,DBT点压视图使三名阅片者的特异度分别从69%升至90%、75%升至94%、68%升至93%(均显著提高),并使一名阅片者的敏感度从67%升至94%(显著提高),另两名阅片者敏感度分别从89%升至100%、100%降至89%(无显著变化)。

临床应用与阅片要点

  • DBT点压视图可能有助于表征DBT不确定发现,减少对良性发现的进一步检查。

局限性

  • 本文为回顾性研究。
  • 点压视图仅由执行放射科医师酌情决定获取。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. A recently introduced digital breast tomosynthesis (DBT) device allows acquisition of DBT spot compression views with a small paddle during DBT acquisition. OBJECTIVE. The purpose of this study was to evaluate the impact on diagnostic performance of obtaining a DBT spot compression view for assessment of equivocal DBT findings. METHODS. This retrospective study included 102 women (mean age, 60 years) in whom a DBT spot compression view was obtained to characterize an equivocal finding on DBT at the performing radiologist's discretion. The DBT examinations were performed from December 14, 2018, to December 18, 2019. Two fellowship-trained breast radiologists and one breast imaging fellow, who were aware of the location of the equivocal lesions, independently reviewed the examinations. Readers first assigned a BI-RADS category using standard DBT views and then immediately assigned a category using the DBT spot compression view. BI-RADS categories 2 and 3 were considered negative, and categories 4A and greater were considered positive. Histology and at least 1 year of imaging follow-up served as the reference standard. Intrareader agreement for one reader and interreader agreement among all readers were evaluated with kappa coefficients. Diagnostic performance was compared between DBT with and DBT without spot compression views by use of McNemar tests. RESULTS. Intrareader agreement increased from 0.43 to 0.72, and interreader agreement increased from 0.21 to 0.45 on the basis of kappa coefficients for DBT without and with spot compression views. Eighteen cancers were present. Compared with standard DBT views, DBT spot compression views yielded significantly increased accuracy for all three readers (75% vs 90%, 74% vs 94%, 72% vs 94%); significantly increased specificity for all three readers (69% vs 90%, 75% vs 94%, 68% vs 93%); and significantly increased sensitivity for one reader (67% vs 94%) without significant change in sensitivity for the two other readers (89% vs 100%, 100% vs 89%). Radiation dose was 1.97 mGy for the DBT spot compression view versus 1.78-1.81 mGy for standard DBT craniocaudal and medio-lateral oblique views. CONCLUSION. Use of the DBT spot compression view increased intrareader agreement, interreader agreement, and diagnostic accuracy (primarily owing to improved specificity); the supplemental dose for the spot compression view was slightly higher than that for a standard DBT view. CLINICAL IMPACT. DBT spot compression may help characterize equivocal DBT findings, reducing further workup for benign findings.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Deleau, Linck, Brouste, et al. Impact of Obtaining a Digital Breast Tomosynthesis (DBT) Spot Compression View on Assessment of Equivocal DBT Findings. AJR Am J Roentgenol. 2022. PMID: 35170358. doi:10.2214/AJR.21.27190

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。