文献速递妇产影像儿科影像腹部US

胎儿腹部囊性包块:临床谱系与产前超声诊断

Fetal Abdominal Cystic Masses: Clinical Spectrum and Prenatal Ultrasound Diagnosis.
PubMed 文献 · J Ultrasound Med · 2022-02-16

研究纳入2019年1月1日至2021年1月1日247例产前超声诊断腹部囊性包块的胎儿,随访至出生后6个月,评估产前超声诊断准确性。总体产前诊断准确率90.7%,各系统间差异有统计学意义(χ2=13.0,P<.05);肾/肾上腺囊性包块准确率最高(96.8%),其他系统最低(60.0%)。结论认为多种囊性包块可在胎儿腹部被准确检出,多数病变可在孕期准确诊断。

要点

  • 胎儿腹部囊性包块最常见的来源为肾/肾上腺(37.7%),其次为肝胆系统(19.4%)、胃肠道(18.2%)。
  • 产前超声总体诊断准确率为90.7%,各系统间差异有统计学意义(χ2=13.0,P<.05)。
  • 肾/肾上腺囊性包块诊断准确率最高(96.8%),生殖系统(82.8%)和其他系统(60.0%)较低。

核心结论

  • 胎儿腹部多种囊性包块可被产前超声准确检出,多数病变可在孕期准确诊断,但不同系统来源包块的诊断准确率存在显著差异。

研究设计与样本

  • 纳入2019年1月1日至2021年1月1日产前超声诊断腹部囊性包块的胎儿247例,测量胎儿基本生物学参数并记录包块位置、形态大小、囊壁厚度、动态变化、血供及与周围器官关系,随访临床资料至出生后6个月。

关键影像表现/征象

  • 观察指标包括囊性包块的位置、形态和大小、囊壁厚度、动态变化、血供以及与周围器官的关系。
  • 同时记录胎儿是否合并其他畸形。

诊断标准与关键数值

  • 总体产前诊断准确率为90.7%。
  • 肾/肾上腺囊性包块诊断准确率为96.8%,输尿管和膀胱为92.6%,胃肠道为91.1%,肝胆系统为85.4%,生殖系统为82.8%,其他系统为60.0%。
  • 各系统间诊断准确率差异有统计学意义(χ2=13.0,P<.05)。

临床应用与阅片要点

  • 产前超声评估胎儿腹部囊性包块时应系统记录位置、形态大小、囊壁厚度、动态变化、血供及与周围器官的关系。
  • 肾/肾上腺来源囊性包块产前诊断准确率较高(96.8%),生殖系统(82.8%)和其他系统(60.0%)包块诊断准确率相对较低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the diagnostic accuracy of prenatal ultrasound in detecting intra-abdominal masses derived from different systems.

METHODS: Fetuses diagnosed with abdominal cystic masses during prenatal ultrasound were included in this study. The basic biological parameters of the fetus were measured in addition to the location of the cystic mass, the shape and size of the mass, the thickness of the cystic wall, dynamic changes, blood supply of the mass, and relationship with the surrounding organs. Whether the fetus also had other malformations was also recorded. Clinical data were followed up to 6 months after birth.

RESULTS: Between January 1, 2019 and January 1, 2021, 247 fetuses were included, most of which contained renal/adrenal cystic masses (n = 93, 37.7%), followed by hepatobiliary system (n = 48, 19.4%), gastrointestinal tract (n = 45, 18.2%), reproductive system (n = 29, 11.7%), and ureter and bladder (n = 27, 10.9%) masses, respectively. The minority were masses in other systems (n = 5, 2.0%). The overall prenatal diagnostic accuracy was 90.7%. There were significant differences in each system (χ2 = 13.0, P < .05). The most accurate type of cyst was diagnosed from renal and adrenal (96.8%) cases, followed by ureter and bladder (92.6%) cases, gastrointestinal tract (91.1%), hepatobiliary system (85.4%), and reproductive system (82.8%). Other systems (60.0%) were the least accurate type.

CONCLUSIONS: A wide variety of cystic masses can be accurately detected in the fetal abdomen, and most of these lesions can be accurately diagnosed during pregnancy.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Wang, Wang, Zeng, et al. Fetal Abdominal Cystic Masses: Clinical Spectrum and Prenatal Ultrasound Diagnosis. J Ultrasound Med. 2022. PMID: 35170798. doi:10.1002/jum.15963

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。