点剪切波与二维剪切波弹性成像预测慢性肝病患者高风险食管静脉曲张:系统评价与Meta分析
该系统评价与Meta分析纳入17篇文献,评估点剪切波弹性成像(pSWE)与二维剪切波弹性成像(2D-SWE)测量的肝硬度(LS)和脾硬度(SS)对高风险食管静脉曲张(HREV)的诊断效能。结果显示LS和SS的pSWE与2D-SWE在敏感度和特异度上无显著差异,但LS的pSWE的AUSROC和DOR高于2D-SWE;SS的pSWE与2D-SWE的DOR无显著差异。结论认为pSWE和2D-SWE测量的LS和SS预测HREV具有良好准确度。
要点
- LS的pSWE与2D-SWE敏感度、特异度无显著差异,pSWE的AUSROC和DOR更高。
- SS的pSWE与2D-SWE敏感度、特异度及DOR均无显著差异。
- pSWE和2D-SWE测量的LS和SS对HREV均有较高敏感度、特异度和AUSROC。
核心结论
- pSWE和2D-SWE测量的LS和SS预测HREV具有良好准确度,两者诊断性能差异不大。
研究设计与样本
- 系统评价与Meta分析,检索PubMed、Embase和Web of Science数据库,纳入17篇报道pSWE或2D-SWE测量LS或SS对HREV诊断性能的文献,采用双变量随机效应模型汇总敏感度、特异度、PLR、NLR、AUSROC和DOR。
诊断标准与关键数值
- LS的pSWE汇总敏感度0.89(95%CI 0.81-0.94) vs 2D-SWE 0.8(95%CI 0.72-0.86),p=0.13;特异度pSWE 0.81(95%CI 0.73-0.87) vs 2D-SWE 0.73(95%CI 0.65-0.79),p=0.07。
- LS的pSWE的AUSROC 0.92(95%CI 0.89-0.94) vs 2D-SWE 0.84(95%CI 0.80-0.87),p=0.03;DOR pSWE 33(95%CI 25-61) vs 2D-SWE 11(95%CI 5-22),p<0.01。
- SS的pSWE汇总敏感度0.91(95%CI 0.78-0.96) vs 2D-SWE 0.89(95%CI 0.80-0.94),p=0.43;特异度pSWE 0.79(95%CI 0.72-0.84) vs 2D-SWE 0.72(95%CI 0.63-0.79),p=0.06。
- SS的pSWE的DOR 35(95%CI 13-100) vs 2D-SWE 20(95%CI 8-50),p=0.16。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess the diagnostic performance of liver stiffness (LS) and spleen stiffness (SS) measured by point shear wave elastography (pSWE) and 2D shear wave elastography (2D-SWE) in the detection of high-risk esophageal varices (HREV) and to compare their diagnostic accuracy.
METHODS: Through systematic search of PubMed, Embase, and Web of Science databases, we included 17 articles reporting the diagnostic performance of LS or SS measured by pSWE or 2D-SWE for HREV. We used a bivariate random-effects model to estimate pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), area under summary receiver operator characteristic curve (AUSROC), and diagnostic odds ratio (DOR).
RESULTS: For LS, there was no significant difference between the pooled sensitivity, 0.89 (95% confidence interval CI, 0.81-0.94) vs. 0.8 (95% CI, 0.72-0.86) (p = 0.13), and specificity, 0.81 (95% CI, 0.73-0.87) vs. 0.73 (95% CI, 0.65-0.79) (p = 0.07) of pSWE and 2D-SWE. The AUSROC and DOR of pSWE were higher than those of 2D-SWE: 0.92 (95% CI, 0.89-0.94) vs. 0.84 (95% CI, 0.80-0.87), p = 0.03, 33 (95% CI, 25-61) vs. 11 (95% CI, 5-22), (p < 0.01). For SS, there was no significant difference between the pooled sensitivity 0.91 (95% CI, 0.78-0.96) vs. 0.89 (95% CI, 0.80-0.94) (p = 0.43); specificity, 0.79 (95% CI, 0.72-0.84) vs. 0.72 (95% CI, 0.63-0.79) (p = 0.06); and DOR, 35 (95% CI, 13-100) vs. 20 (95% CI, 8-50) (p = 0.16) of pSWE and 2D-SWE.
CONCLUSION: LS and SS measured by pSWE and 2D-SWE have good accuracy in predicting HREV.
KEY POINTS: • There is modest difference between the diagnostic performance of LS and SS measured by pSWE and 2D-SWE. • LS and SS measured by pSWE and 2D-SWE both have high sensitivity, specificity, and AUSROC for the evaluation of HREV in patients with CLD. • pSWE and 2D-SWE are promising tools for noninvasive monitoring risk of esophageal varices bleeding of CLD patients.
引用
- Liu, Tan, Zhang, et al. Prediction of high-risk esophageal varices in patients with chronic liver disease with point and 2D shear wave elastography: a systematic review and meta-analysis. Eur Radiol. 2022. PMID: 35166896. doi:10.1007/s00330-022-08601-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。