文献速递心血管CT

光子计数CT冠状动脉CT血管成像:首次人体研究结果

Coronary CT Angiography with Photon-counting CT: First-In-Human Results.
PubMed 文献 · Radiology · 2022-02-15

本前瞻性研究纳入14例冠状动脉疾病患者,在同一患者中比较临床原型光子计数CT(PCCT)与能量积分探测器双层CT(EID DLCT)回顾性心电门控冠状动脉CTA的图像质量。PCCT整体图像质量和诊断信心评分更高(中位5分 vs 4分,P<.01),钙化、支架及非钙化斑块诊断质量改善比例分别为100%、92%和45%。

要点

  • PCCT整体图像质量与诊断信心中位评分均为5分,EID DLCT分别为4分(P<.01)。
  • PCCT钙化、支架、非钙化斑块诊断质量改善比例分别为100%、92%、45%。
  • 体模中PCCT管腔和非钙化斑块可探测性指数分别高2.3倍和2.9倍。

核心结论

  • 在人体中,光子计数CT冠状动脉CTA较能量积分双层CT显示出更高的图像质量和诊断信心。

研究设计与样本

  • 前瞻性经委员会批准并获知情同意的研究,连续纳入14例冠状动脉疾病参与者(12名男性,平均年龄61岁±17),均行两种系统回顾性心电门控冠状动脉CTA;先行体模任务型冠状动脉病变可探测性指数评估;PCCT采用超高分辨率参数(1024矩阵、0.25 mm层厚),EID DLCT采用512矩阵、0.67 mm层厚。

关键影像表现/征象

  • PCCT整体图像质量中位评分5分(四分位距2),EID DLCT为4分(四分位距1)。
  • PCCT诊断信心中位评分5分(四分位距1),EID DLCT为4分(四分位距3)。
  • PCCT钙化、支架、非钙化斑块诊断质量改善比例分别为100%、92%(95%CI:71,98)、45%(95%CI:28,63)。
  • 体模研究中PCCT管腔可探测性指数高2.3倍,非钙化斑块高2.9倍。

诊断标准与关键数值

  • 采用五点质量评分(1=不足,5=优秀)评估整体图像质量、诊断信心及钙化、支架、非钙化斑块的诊断质量。
  • PCCT平均管电流255 mAs±0,EID DLCT为349 mAs±111(P<.01)。
  • 对比剂注射方案为65-75 mL、400 mg/mL碘对比剂,流率5 mL/sec。

临床应用与阅片要点

  • PCCT超高分辨率参数(1024矩阵、0.25 mm层厚)用于冠状动脉CTA可提高图像质量和诊断信心。
  • PCCT对钙化、支架及非钙化斑块的诊断质量改善比例分别为100%、92%、45%。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images (P < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sandfort and Bluemke in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Si-Mohamed, Boccalini, Lacombe, et al. Coronary CT Angiography with Photon-counting CT: First-In-Human Results. Radiology. 2022. PMID: 35166583. doi:10.1148/radiol.211780

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。