文献速递骨肌MR

压缩感知敏感度编码(SENSE)高分辨率磁共振成像评估三角纤维软骨复合体

High-resolution magnetic resonance imaging of the triangular fibrocartilage complex using compressed sensing sensitivity encoding (SENSE).
PubMed 文献 · Eur J Radiol · 2022-02-03

研究纳入13名健康志愿者,比较原始序列与联合压缩感知敏感度编码(CS-SENSE)的高分辨及超高分辨序列对三角纤维软骨复合体(TFCC)的显示效果。HR(CS-SENSE)序列在尺骨茎突尖三角韧带、背侧桡尺韧带和尺三角韧带的可视化评分优于原始序列,整体图像质量无显著差异,相对信号强度和对比度较低,作者认为该序列可能具有临床实用性。

要点

  • HR(CS-SENSE)序列对尺骨茎突尖三角韧带、背侧桡尺韧带和尺三角韧带的显示评分优于原始序列。
  • HR与S-HR序列中各有3例(13例中)出现运动伪影,整体图像质量评分与原始序列无显著差异。
  • 原始序列的骨髓相对信号强度及软骨-骨髓、软骨-三角纤维软骨盘相对对比度高于HR(CS-SENSE)和S-HR(CS-SENSE)序列。

核心结论

  • 在三种序列中,HR(CS-SENSE)序列的可视化评分最高且图像质量满足诊断需求,尽管相对信号强度和相对对比度较低;该序列可能对TFCC成像具有临床实用价值。

研究设计与样本

  • 研究纳入13名健康志愿者,获取三维快速场回波T2加权图像,采用原始序列、高空间分辨率序列加或不加CS-SENSE(HR和HR(CS-SENSE))、超高空间分辨率序列加或不加CS-SENSE(S-HR和S-HR(CS-SENSE));定性分析计数运动伪影并分级TFCC解剖结构可视化和整体图像质量,定量分析计算月骨骨髓、月骨软骨和三角纤维软骨盘的相对信号强度和相对对比度。

关键影像表现/征象

  • HR(CS-SENSE)序列在尺骨茎突尖三角韧带、背侧桡尺韧带和尺三角韧带的可视化评分优于原始序列。
  • S-HR(CS-SENSE)序列在尺骨茎突尖三角韧带和背侧桡尺韧带的可视化评分优于原始序列。
  • HR和S-HR序列中各有3例(13例中)观察到运动伪影。

诊断标准与关键数值

  • 整体图像质量评分在HR(CS-SENSE)与原始序列间无显著差异。
  • 原始序列的骨髓相对信号强度及软骨-骨髓、软骨-三角纤维软骨盘相对对比度高于HR(CS-SENSE)和S-HR(CS-SENSE)序列。

临床应用与阅片要点

  • 作者认为HR(CS-SENSE)序列可能对TFCC成像具有临床实用价值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the optimal sequence for high-resolution magnetic resonance imaging (MRI) of the triangular fibrocartilage complex (TFCC) using compressed sensing-sensitivity encoding (CS-SENSE).

METHODS: Three-dimensional fast field echo T2-weighted images were obtained from 13 healthy volunteers using the original, high spatial resolution sequence with CS-SENSE [HR (CS-SENSE)] and without CS-SENSE (HR) and super-high spatial resolution sequence with CS-SENSE [S-HR (CS-SENSE)] and without CS-SENSE (S-HR). For qualitative analysis, the number of patients affected by motion artifacts in each sequence was counted, and the visualization of the TFCC anatomic structures and overall image quality were categorized. For the quantitative analysis, relative signal intensity (SI) and relative contrast of the lunate bone marrow, lunate cartilage, and disk proper in the wrist joint were all calculated.

RESULTS: The HR (CS-SENSE) sequence showed better visualization scores than the original sequence in the triangular ligament at the ulnar styloid tip, dorsal radioulnar ligament, and ulnotriquetral ligament. Similarly, the S-HR (CS-SENSE) sequence showed better visualization scores than the original sequence in the triangular ligament at the ulnar styloid tip and dorsal radioulnar ligament. Overall image quality scores were not significantly different, and motion artifacts in the HR and S-HR sequences were observed in 3 of the 13 patients. In contrast, the original sequence showed higher values than those in the HR (CS-SENSE) and S-HR (CS-SENSE) sequences in relative SI of the bone marrow and relative contrast of the cartilage-bone marrow and cartilage-disk proper.

CONCLUSIONS: Out of the three sequences, the HR (CS-SENSE) sequence provided the highest visualization score and diagnostically sufficient image quality score, although relative SI and relative contrast were low. The HR (CS-SENSE) sequence may be clinically useful for imaging TFCCs.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Fujiwara, Yabuuchi, Wada, et al. High-resolution magnetic resonance imaging of the triangular fibrocartilage complex using compressed sensing sensitivity encoding (SENSE). Eur J Radiol. 2022. PMID: 35149336. doi:10.1016/j.ejrad.2022.110191

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。