文献速递腹部技术与安全MR

基于磁共振弹性成像的剪切应变图评估肝细胞癌微血管侵犯

MR Elastography-Based Shear Strain Mapping for Assessment of Microvascular Invasion in Hepatocellular Carcinoma.
PubMed 文献 · Eur Radiol · 2022-02-11

回顾性纳入59例经病理证实的肝细胞癌患者,其中34例有微血管侵犯(MVI)、25例无MVI,均行60Hz磁共振弹性成像(MRE),29例另加行40Hz和30Hz MRE;测量瘤周低剪切应变界面长度百分比(OSS-pLSL),发现MVI阳性组高于MVI阴性组(三个频率均p<0.01),预测MVI的AUC在60Hz为0.73(n=59)/0.80(n=29)、40Hz为0.84、30Hz为0.90,作者认为最推荐频率为30Hz。

要点

  • MVI阳性组瘤周低剪切应变界面长度百分比在三个MRE频率下均显著高于MVI阴性组(均p<0.01)。
  • 30Hz和40Hz MRE的瘤周OSS-pLSL预测MVI的AUC分别为0.90和0.84,均高于60Hz的0.73(n=59)/0.80(n=29)。
  • MRE剪切应变图可能无创预测肝细胞癌MVI,作者推荐最适频率为30Hz。

核心结论

  • 基于MRE的剪切应变图是术前无创预测肝细胞癌MVI的有前景技术,作者推荐最适频率为30Hz。

研究设计与样本

  • 回顾性纳入2016年12月至2019年10月间59例经组织病理学证实的肝细胞癌患者,MVI阳性34例、阴性25例,均行常规60Hz MRE检查。
  • 其中29例患者(MVI阳性16例、阴性13例)另接受40Hz和30Hz MRE检查。
  • 计算八面体剪切应变(OSS)图,记录瘤周界面低剪切应变长度百分比(OSS-pLSL,%),以组织病理学为参考标准。
  • 采用Mann-Whitney检验比较MVI阳性与阴性组间OSS-pLSL差异,采用受试者工作特征曲线下面积(AUC)评价诊断效能。

关键影像表现/征象

  • MVI阳性组瘤周OSS-pLSL在60Hz、40Hz、30Hz三个频率下均显著高于MVI阴性组(均p<0.01)。
  • 肿瘤-肝边界处低界面剪切应变与MVI存在高度相关性。

诊断标准与关键数值

  • 瘤周OSS-pLSL预测MVI的AUC:60Hz为0.73(n=59)/0.80(n=29),40Hz为0.84,30Hz为0.90。
  • 29例完成三个频率检查的病例中,各频率AUC之间无显著差异。
  • 随频率从60Hz降低,OSS特异度在40Hz由53.8%升至61.5%,在30Hz进一步由53.8%升至76.9%;敏感度在较低频率下仍保持较高(由100.0%至93.8%)(均p>0.05)。

临床应用与阅片要点

  • 作者认为MRE剪切应变图可能用于术前无创预测肝细胞癌MVI。
  • 作者推荐OSS的最适频率为30Hz。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the potential of MR elastography (MRE)-based shear strain mapping to noninvasively predict the presence of microvascular invasion (MVI) in hepatocellular carcinoma (HCC).

METHODS: Fifty-nine histopathology-proven HCC patients with conventional 60-Hz MRE examinations (+/-MVI, n = 34/25) were enrolled retrospectively between December 2016 and October 2019, with one subgroup comprising 29/59 patients (+/-MVI, n = 16/13) who also underwent 40- and 30-Hz MRE examinations. Octahedral shear strain (OSS) maps were calculated, and the percentage of peritumoral interface length with low shear strain (i.e., a low-shear-strain length, pLSL, %) was recorded. For OSS-pLSL, differences between the MVI (+) and MVI (-) groups and diagnostic performance at different MRE frequencies were analyzed using the Mann-Whitney test and area under the receiver operating characteristic curve (AUC), respectively.

RESULTS: The peritumor OSS-pLSL was significantly higher in the MVI (+) group than in the MVI (-) group at the three frequencies (all p < 0.01). The AUC of peritumor OSS-pLSL for predicting MVI was good/excellent in all frequency groups (60-Hz: 0.73 (n = 59)/0.80 (n = 29); 40-Hz: 0.84; 30-Hz: 0.90). On further analysis of the 29 cases with all frequencies, the AUCs were not significantly different. As the frequency decreased from 60-Hz, the specificity of OSS increased at 40-Hz (53.8-61.5%) and further increased at 30-Hz (53.8-76.9%), and the sensitivity remained high at lower frequencies (100.0-93.8%) (all p > 0.05).

CONCLUSIONS: MRE-based shear strain mapping is a promising technique for noninvasively predicting the presence of MVI in patients with HCC, and the most recommended frequency for OSS is 30-Hz.

KEY POINTS: • MR elastography (MRE)-based shear strain mapping has the potential to predict the presence of microvascular invasion (MVI) in hepatocellular carcinoma preoperatively. • The low interface shear strain identified at tumor-liver boundaries was highly correlated with the presence of MVI.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Li, Yin, Hu, et al. MR Elastography-Based Shear Strain Mapping for Assessment of Microvascular Invasion in Hepatocellular Carcinoma. Eur Radiol. 2022. PMID: 35147777. doi:10.1007/s00330-022-08578-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。