海平面地区估测体重低于第10百分位胎儿的心脏大小、形态与心室收缩力研究
前瞻性超声研究纳入37例海平面地区估测胎儿体重低于第10百分位的胎儿,用高频电影回放和斑点追踪评估四腔心大小、球形指数及双心室收缩力,并与正常对照及丹佛高海拔类似研究比较。约三分之一海平面小胎儿心脏增大呈球形、双侧心室肥厚且收缩力增加,高海拔胎儿心脏形态相似但收缩力减低比例更高。
要点
- 海平面地区估测体重低于第10百分位胎儿约三分之一出现四腔心增大呈球形。
- 该类胎儿常见双侧心室肥厚,整体及纵向心室收缩力较正常对照增加。
- 高海拔同类胎儿心脏形态相似,但心室收缩力减低的比例高于海平面队列。
核心结论
- 海平面地区估测体重低于第10百分位的晚孕期胎儿常伴有心脏增大呈球形,整体及纵向心室收缩力较对照增加;高海拔胎儿心脏形态相似但收缩力减低比例更高。
研究设计与样本
- 前瞻性超声研究,纳入37例海平面地区(休斯顿)估测胎儿体重低于第10百分位的胎儿,采用高频电影回放评估四腔心舒张末期测量及整体球形指数,用斑点追踪分析双心室大小、形态与收缩力,以正常对照均值±标准差计算Z评分,并与丹佛高海拔类似已发表研究比较。
关键影像表现/征象
- 约三分之一海平面小胎儿四腔心增大呈球形,右心室面积、右心室基底-心尖长度、右心室基底宽度及左心室基底-心尖长度增加。
- 双侧心室肥厚常存在。
- 海平面小胎儿心室收缩力增加的比例增高,而高海拔胎儿心室收缩力减低更常见。
诊断标准与关键数值
- Z评分基于正常对照均值±标准差计算,Z值小于-1.65或大于+1.65定义为测量异常。
- 比较异常参数比例与正常参考范围,并与丹佛高海拔小胎儿研究结果对比。
临床应用与阅片要点
- 海平面地区估测体重低于第10百分位胎儿中,约三分之一可见心脏增大呈球形伴双侧心室肥厚,收缩力常增加。
- 高海拔同类胎儿心脏形态相似,但心室收缩力减低比例更高。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate cardiac size, shape, and ventricular contractility in fetuses with estimated fetal weight (EFW) <10th centile at sea level (Houston).
METHODS: A prospective ultrasound study examined 37 fetuses with EFW <10th centile at sea level. High-frequency cine clips were used to evaluate the 4-chamber view including end-diastolic measurements and global sphericity index. The size, shape, and contractility of both ventricles were analyzed with speckle tracking methods. Z scores were calculated using the mean ± standard deviation (SD) derived from normal controls. Measurements were abnormal if their Z score values were <-1.65 or >+1.65. The proportion of small fetuses with abnormal parameters was compared to normal reference ranges. Results were compared to a similar published study of small fetuses at higher altitude in Denver.
RESULTS: About one-third of Houston fetuses with EFW <10th centile had enlarged globular shaped 4-chamber hearts with increased right ventricle (RV) area, RV basal-apical length, RV base width, and left ventricle (LV) basal-apical length measurements. Bilateral ventricular hypertrophy was often present. An increased proportion of Houston fetuses had increased ventricular contractility. However, decreased ventricular contractility was more prevalent for higher altitude fetuses.
CONCLUSIONS: Third trimester fetuses at sea level, with an EFW <10th centile, were often associated with enlarged and globular-shaped hearts. They had increased global and longitudinal ventricular contractility as compared to controls. Higher altitude fetuses also had enlarged globular-shaped hearts but with a greater proportion of cases having decreased ventricular contractility as compared to the sea level cohort.
引用
- Lee, Mack, Miremadi, et al. Cardiac Size, Shape, and Ventricular Contractility in Fetuses at Sea Level With an Estimated Weight Less-than 10th Centile. J Ultrasound Med. 2022. PMID: 35142391. doi:10.1002/jum.15954
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。