文献速递腹部技术与安全MR

自由呼吸下的动态肝脏磁共振成像:一种运动补偿可变密度径向采集与视图共享高通滤波重建的可行性研究

Dynamic Liver Magnetic Resonance Imaging During Free Breathing: A Feasibility Study With a Motion Compensated Variable Density Radial Acquisition and a Viewsharing High-Pass Filtering Reconstruction.
PubMed 文献 · Invest Radiol · 2022-02-09

前瞻性初步研究纳入27例患者,比较自由呼吸原型序列4DFreeBreathing与标准屏气序列动态肝脏MRI的图像质量、运动伪影和血管显示。4DFreeBreathing图像质量与金标准无显著差异(P=0.34),运动伪影显著更少(P<0.0001),晚期动脉期正确捕获27/27(100%)对比屏气序列35/53(66%)(P<0.001)。

要点

  • 4DFreeBreathing自由呼吸动态序列在27例中均获得无运动伪影的高时间分辨率图像。
  • 图像质量与屏气金标准无显著差异(P=0.34),运动伪影显著更少(P<0.0001)。
  • 晚期动脉期正确捕获100%(27/27)对比屏气序列66%(35/53),P<0.001。

核心结论

  • 4DFreeBreathing重建便捷快速,运动鲁棒性和时机优于标准屏气序列,是动态肝脏MRI中有吸引力的自由呼吸技术替代方案。

研究设计与样本

  • 前瞻性初步研究,27例患者接受常规腹部MRI协议,包括原型自由呼吸序列(4DFreeBreathing)行动态成像,随后以标准屏气序列为参考标准。

诊断标准与关键数值

  • 图像质量、运动伪影和血管显示采用5分Likert量表评估。
  • 4DFreeBreathing与金标准总体图像质量评分为良好或优秀,无显著差异(P=0.34)。
  • 4DFreeBreathing运动伪影显著更少(P<0.0001)。
  • 各动态期相血管显示两组相当(P=0.45、P>0.99、P=0.22)。
  • 晚期动脉期正确捕获4DFreeBreathing 27/27(100%)对比金标准35/53(66%)(P<0.001)。

临床应用与阅片要点

  • 4DFreeBreathing自由呼吸动态序列可用于无法配合屏气的患者,获得与屏气序列相当的图像质量和血管显示,并显著减少运动伪影、提高晚期动脉期捕获率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Robust dynamic contrast-enhanced T1-weighted images are crucial for accurate detection and categorization of focal liver lesions in liver/abdominal magnetic resonance imaging (MRI). As optimal dynamic imaging usually requires multiple breath-holds, its inherent susceptibility to motion artifacts frequently results in degraded image quality in incompliant patients. Because free-breathing imaging may overcome this drawback, the intention of this study was to evaluate a dynamic MRI sequence acquired during free breathing using the variable density, elliptical centric golden angle radial stack-of-stars radial sampling scheme, which so far has not been implemented in 4-dimensional applications.

MATERIALS AND METHODS: In a prospective pilot study, 27 patients received a routine abdominal MRI protocol including the prototype free-breathing sequence (4DFreeBreathing) for dynamic imaging. This enables more convenient and faster reconstruction through variable density, elliptical centric golden angle radial stack-of-stars without the use of additional reconstruction hardware, and even higher motion robustness through soft-gating. A standard breath-hold sequence performed subsequently served as reference standard. Of the continuous dynamic data sets, each dynamic phase was analyzed regarding image quality, motion artifacts and vessel conspicuity using 5-point Likert scales. Furthermore, correct timing of the late arterial phase was compared with the preexaminations.

RESULTS: 4DFreeBreathing delivered motion-free dynamic images with high temporal resolution in each subject. Overall image quality scores were rated good or excellent for 4DFreeBreathing and the gold standard without significant differences (P = 0.34). There were significantly less motion artifacts in the 4DFreeBreathing sequence (P < 0.0001), whereas vessel conspicuity in each dynamic phase was comparable for both groups (P = 0.45, P > 0.99, P = 0.22, respectively). Correct timing of the late arterial phase could be achieved in 27 of 27 (100%) examinations using 4DFreeBreathing versus 35 of 53 (66%) preexaminations using gold standard (P < 0.001).

CONCLUSION: The benefit of convenient and fast image reconstruction combined with the superiority in motion robustness and timing compared with standard breath hold sequences renders 4DFreeBreathing an attractive alternative to existing free-breathing techniques in dynamic liver MRI.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Endler, Kukuk, Peeters, et al. Dynamic Liver Magnetic Resonance Imaging During Free Breathing: A Feasibility Study With a Motion Compensated Variable Density Radial Acquisition and a Viewsharing High-Pass Filtering Reconstruction. Invest Radiol. 2022. PMID: 35136004. doi:10.1097/RLI.0000000000000859

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。