文献速递神经外周血管CTDSA

人工智能辅助提高CT血管造影检测颅内动脉瘤的准确性和效率

Artificial intelligence assistance improves the accuracy and efficiency of intracranial aneurysm detection with CT angiography.
PubMed 文献 · Eur J Radiol · 2022-01-20

回顾性纳入212例同时行CTA和DSA的患者,以DSA为金标准比较AI、医师及AI+医师三种模式检测颅内动脉瘤的效能。AI辅助使低年资医师诊断效能与高年资医师相近,并分别提升低年资和高年资医师报告效率20.7%和18.8%。

要点

  • AI辅助使低年资医师诊断效能与高年资医师相近,患者水平准确率87.7%对89.2%。
  • AI辅助使低年资和高年资医师报告时间分别缩短20.7%和18.8%。
  • 对<5mm动脉瘤,AI辅助下低年资与高年资医师敏感度83.2%对87.6%。

核心结论

  • 基于3D-CNN的AI系统显著提高了医师检测颅内动脉瘤的准确性和效率,AI+医师工作模式可能对日常临床实践和临床研究产生重要影响。

研究设计与样本

  • 回顾性纳入212例同时行CTA和DSA的患者,以DSA为金标准,在患者水平和病灶水平比较AI、医师、AI+医师三种诊断模式的敏感度、特异度、准确率、平均报告时间和观察者间一致性。

诊断标准与关键数值

  • AI系统患者水平诊断动脉瘤的敏感度84.9%(95%CI 78.9-89.5%)、特异度18.2%(95%CI 8.2-34.8%)、准确率74.5%(95%CI 68.3-80.0%)。
  • AI系统病灶水平诊断动脉瘤的敏感度77.2%(95%CI 71.3-82.3%)、特异度14.0%(95%CI 6.2-27.6%)、准确率67.0%(95%CI 61.2-72.4%)。
  • AI辅助下低年资与高年资医师患者水平敏感度95.0%对95.0%、特异度48.5%对57.6%、准确率87.7%对89.2%(p=0.690)。
  • AI辅助下低年资与高年资医师病灶水平敏感度88.0%对89.7%、特异度32.0%对38.0%、准确率77.8%对80.3%(p=1.000)。
  • 对<5mm动脉瘤,AI辅助下低年资与高年资医师敏感度83.2%对87.6%、特异度60.0%对63.2%、准确率75.4%对78.9%(p=0.424)。

临床应用与阅片要点

  • AI辅助可使低年资医师诊断效能达到与高年资医师相近水平,尤其对<5mm动脉瘤。
  • AI辅助可提升医师报告效率,低年资医师报告时间从141.1±52.6s降至111.9±46.3s(p=0.004),高年资医师从113.2±42.5s降至91.9±41.2s(p=0.011)。
  • 作者认为AI+医师工作模式可能对日常临床实践和临床研究产生重要影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to evaluate whether a novel head and neck artificial intelligence (AI)-assisted diagnostic system based on a three-dimensional convolutional neural network (3D-CNN) could improve the accuracy, efficiency and working mode of intracranial aneurysm (IA) detection.

METHODS: A total of 212 patients who underwent computed tomography angiography (CTA) and digital subtraction angiography (DSA) were retrospectively included. We used three diagnostic modes to detect IAs with CTA: AI, physicians and AI + physicians. Taking the diagnostic results of DSA as the gold standard, the sensitivity, specificity, accuracy, mean reporting time, and interobserver consistency of the three diagnostic modes were calculated and compared at the patient and lesion levels.

RESULTS: Of 212 patients, 179 were diagnosed with IAs by DSA, and 224 IAs were analyzed. The sensitivity, specificity and accuracy of the AI system in diagnosing aneurysms were 84.9% (95% confidence interval [CI], 78.9-89.5%), 18.2% (95% CI, 8.2-34.8%) and 74.5% (95% CI, 68.3-80.0%) at the patient-level, and 77.2% (95% CI, 71.3-82.3%), 14.0% (95% CI, 6.2-27.6%) and 67.0% (95% CI, 61.2-72.4%) at the lesion-level, respectively. With AI assistance, junior physicians had the similar diagnostic performance as senior physicians at the patient (sensitivity 95.0% vs. 95.0%, specificity 48.5% vs. 57.6%, accuracy 87.7% vs. 89.2%, p = 0.690) and lesion levels (sensitivity 88.0% vs. 89.7%, specificity 32.0% vs. 38.0%, accuracy 77.8% vs. 80.3%, p = 1.000), especially for aneurysms < 5 mm (sensitivity 83.2% vs. 87.6%, specificity 60.0% vs. 63.2%, accuracy 75.4% vs. 78.9%, p = 0.424). The reporting efficiency of junior and senior physicians improved by 20.7% (141.1 ± 52.6 s to 111.9 ± 46.3 s, p = 0.004) and 18.8% (113.2 ± 42.5 s to 91.9 ± 41.2 s, p = 0.011), respectively.

CONCLUSIONS: This 3D-CNN-based AI system significantly improved the accuracy and efficiency of physician detection of IA. The AI + physicians work mode could have a major influence on daily clinical practice and clinical research.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Wei, Jiang, Cao, et al. Artificial intelligence assistance improves the accuracy and efficiency of intracranial aneurysm detection with CT angiography. Eur J Radiol. 2022. PMID: 35139447. doi:10.1016/j.ejrad.2022.110169

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。