人工智能软件诊断急性缺血性卒中患者颅内动脉闭塞
回顾性评估人工智能软件(StrokeViewer)在CT血管造影(CTA)上诊断前循环近端颅内动脉闭塞的诊断性能,并与临床实践中的手动阅读比较。474例急性缺血性卒中患者中,参考标准确认75例(15.8%)存在前循环近端动脉闭塞。AI软件敏感度与手动阅读无显著差异(77.3% vs. 78.7%,P=1.000),特异度显著低于手动阅读(88.5% vs. 100%,P<0.001);AI软件正确识别42例大血管闭塞中的40例(95.2%)和33例中等血管闭塞中的18例(54.5%),并检出16例手动阅读漏诊的颅内动脉闭塞中的8例(50%)。
要点
- AI软件(StrokeViewer)诊断前循环近端动脉闭塞的敏感度与手动阅读无显著差异,特异度显著低于手动阅读。
- AI软件对大血管闭塞(LVO)检出率高(40/42,95.2%),对中等血管闭塞(MeVO)检出率较低(18/33,54.5%)。
- AI软件可检出部分手动阅读漏诊的颅内动脉闭塞(8/16,50%)。
核心结论
- 当前AI软件检测颅内动脉闭塞具有中等敏感度和较高特异度,可能检出部分手动阅读漏诊的闭塞,可能在临床卒中诊疗中有价值。
研究设计与样本
- 回顾性研究,纳入474例急性缺血性卒中患者,以两名神经放射科医生对CTA的回顾性判读为参考标准,比较AI软件(StrokeViewer)与手动阅读的敏感度和特异度(McNemar检验)。
诊断标准与关键数值
- 参考标准确认75例(15.8%)存在前循环近端动脉闭塞;AI软件敏感度77.3% vs. 手动阅读78.7%(P=1.000),特异度88.5% vs. 100%(P<0.001);AI软件正确识别LVO 40/42(95.2%)、MeVO 18/33(54.5%);AI软件检出16例手动阅读漏诊闭塞中的8例(50%)。
临床应用与阅片要点
- 作者认为AI软件可能检出部分手动阅读漏诊的颅内动脉闭塞,可能在临床卒中诊疗中有价值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic performance of AI software in diagnosing intracranial arterial occlusions in the proximal anterior circulation at CT angiography (CTA) and to compare it to manual reading performed in clinical practice.
METHODS: Patients with acute ischemic stroke underwent CTA to detect arterial occlusion in the proximal anterior circulation. Retrospective review of CTA scans by two neuroradiologists served as reference standard. Sensitivity and specificity of AI software (StrokeViewer) were compared to those of manual reading using the McNemar test. The proportions of correctly detected occlusions in the distal internal carotid artery and/or M1 segment of the middle cerebral artery (large vessel occlusion [LVO]) and in the M2 segment of the middle cerebral artery (medium vessel occlusion [MeVO]) were calculated.
RESULTS: Of the 474 patients, 75 (15.8%) had an arterial occlusion in the proximal anterior circulation according to the reference standard. Sensitivity of StrokeViewer software was not significantly different compared to that of manual reading (77.3% vs. 78.7%, P = 1.000). Specificity of StrokeViewer software was significantly lower than that of manual reading (88.5% vs. 100%, P < 0.001). StrokeViewer software correctly identified 40 of 42 LVOs (95.2%) and 18 of 33 MeVOs (54.5%). StrokeViewer software detected 8 of 16 (50%) intracranial arterial occlusions which were missed by manual reading.
CONCLUSION: The current AI software detected intracranial arterial occlusion with moderate sensitivity and fairly high specificity. The AI software may detect additional occlusions which are missed by manual reading. As such, the use of AI software may be of value in clinical stroke care.
引用
- Fasen, Berendsen, Kwee, et al. Artificial intelligence software for diagnosing intracranial arterial occlusion in patients with acute ischemic stroke. Neuroradiology. 2022. PMID: 35137270. doi:10.1007/s00234-022-02912-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。