基于神经网络与乳腺密度在筛查乳腺X线阴性女性中检测间期癌
本回顾性巢式病例对照研究纳入2222例间期癌女性与4661例对照,评估结合乳腺密度与人工智能癌症检测系统的神经网络模型预测间期癌风险的表现。神经网络模型AUC为0.79,高于单独AI系统(0.73)或乳腺密度(0.69);在90%特异度下,神经网络模型敏感度为50.9%,高于AI系统的37.5%或单独乳腺密度百分比的22.4%。结论认为联合评估有助于识别更大比例的间期癌女性。
要点
- 联合AI评分与乳腺密度的神经网络模型预测间期癌的AUC为0.79,高于单独AI或密度。
- 在90%特异度下,联合模型敏感度50.9%,高于AI系统的37.5%和乳腺密度的22.4%。
- 联合评估可在筛查阴性女性中识别更多未来发生间期癌的高风险个体。
核心结论
- 联合人工智能检测系统与乳腺密度测量可识别更大比例的未来发生间期癌的女性,优于任一方法单独使用。
研究设计与样本
- 回顾性巢式病例对照研究,纳入2011年1月至2015年间的筛查检查,包括2222例发生间期癌的女性和4661例随访正常的对照女性(平均年龄61岁,范围49-76岁);AI癌症检测系统对全部检查给出1-10分(分值越高恶性可能性越大),乳腺密度由公开软件自动计算,神经网络模型通过10折交叉验证结合AI评分与乳腺密度,采用Bootstrap分析计算AUC、90%特异度下的敏感度及95%CI。
诊断标准与关键数值
- 神经网络模型预测间期癌的AUC为0.79(95%CI:0.77,0.81),高于AI癌症检测系统的0.73(95%CI:0.71,0.76)和乳腺密度的0.69(95%CI:0.67,0.71),两者P均<.001;在90%特异度下,神经网络模型敏感度为50.9%(339/666例;95%CI:45.2,56.3),高于AI系统的37.5%(250/666例;95%CI:33.0,43.7;P<.001)和单独乳腺密度百分比的22.4%(149/666例;95%CI:17.9,28.5;P<.001)。
临床应用与阅片要点
- 作者结论认为,联合人工智能检测系统与乳腺密度测量可在筛查乳腺X线阴性女性中识别更大比例的未来间期癌个体, compared with either method alone。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Inclusion of mammographic breast density (BD) in breast cancer risk models improves accuracy, but accuracy remains modest. Interval cancer (IC) risk prediction may be improved by combining assessments of BD and an artificial intelligence (AI) cancer detection system. Purpose To evaluate the performance of a neural network (NN)-based model that combines the assessments of BD and an AI system in the prediction of risk of developing IC among women with negative screening mammography results. Materials and Methods This retrospective nested case-control study performed with screening examinations included women who developed IC and women with normal follow-up findings (from January 2011 to January 2015). An AI cancer detection system analyzed all studies yielding a score of 1-10, representing increasing likelihood of malignancy. BD was automatically computed using publicly available software. An NN model was trained by combining the AI score and BD using 10-fold cross-validation. Bootstrap analysis was used to calculate the area under the receiver operating characteristic curve (AUC), sensitivity at 90% specificity, and 95% CIs of the AI, BD, and NN models. Results A total of 2222 women with IC and 4661 women in the control group were included (mean age, 61 years; age range, 49-76 years). AUC of the NN model was 0.79 (95% CI: 0.77,0.81), which was higher than AUC of the AI cancer detection system or BD alone (AUC, 0.73 [95% CI: 0.71, 0.76] and 0.69 [95% CI: 0.67, 0.71], respectively; P < .001 for both). At 90% specificity, the NN model had a sensitivity of 50.9% (339 of 666 women; 95% CI: 45.2, 56.3) for prediction of IC, which was higher than that of the AI system (37.5%; 250 of 666 women; 95% CI: 33.0, 43.7; P < .001) or BD percentage alone (22.4%; 149 of 666 women; 95% CI: 17.9, 28.5; P < .001). Conclusion The combined assessment of an artificial intelligence detection system and breast density measurements enabled identification of a larger proportion of women who would develop interval cancer compared with either method alone. Published under a CC BY 4.0 license.
引用
- Wanders, Mees, Bun, et al. Interval Cancer Detection Using a Neural Network and Breast Density in Women with Negative Screening Mammograms. Radiology. 2022. PMID: 35133194. doi:10.1148/radiol.210832
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。