文献速递胸部技术与安全CT

基于深度学习的肺癌筛查低剂量CT自动扫描范围设定模型的开发

Development of Deep Learning-based Automatic Scan Range Setting Model for Lung Cancer Screening Low-dose CT Imaging.
PubMed 文献 · Acad Radiol · 2022-02-05

本研究利用1984例肺癌筛查低剂量CT扫描开发基于深度学习的自动扫描范围设定系统,并与放射技师设定的扫描范围比较。结果显示该系统仅用正位定位像即可高精度预测扫描范围,上界准确率97.08%(233/240)、过扫描率0%(0/240),下界准确率96.25%(231/240)、过扫描率29.58%(71/240)。

要点

  • 深度学习系统仅用正位定位像即可自动设定肺癌筛查低剂量CT扫描范围。
  • 上界准确率97.08%(233/240),过扫描率0%(0/240)。
  • 下界准确率96.25%(231/240),过扫描率29.58%(71/240)。

核心结论

  • 所开发的深度学习算法系统仅使用正位定位像即可高效、高精度地预测肺癌筛查低剂量CT的扫描范围。

研究设计与样本

  • 回顾性研究,使用2019年11月至2020年5月间获取的1984例肺癌筛查低剂量CT扫描;其中600例用于观察定位像标志与真实肺边界的关系,1144例用于算法开发,按8:2分为训练集915例和验证集229例,测试集240例;以真实肺边界和放射技师设定的扫描范围为参考。

诊断标准与关键数值

  • 深度学习算法上界与真实肺边界的平均差异为4.72±3.15 mm,下界平均差异为16.50±14.06 mm;上界准确率97.08%(233/240)、过扫描率0%(0/240),下界准确率96.25%(231/240)、过扫描率29.58%(71/240)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To develop an automatic setting of a deep learning-based system for detecting low-dose computed tomography (CT) lung cancer screening scan range and compare its efficiency with the radiographer's performance.

MATERIALS AND METHODS: This retrospective study was performed using 1984 lung cancer screening low-dose CT scans obtained between November 2019 and May 2020. Among 1984 CT scans, 600 CT scans were considered suitable for an observational study to explore the relationship between the scout landmarks and the actual lung boundaries. Further, 1144 CT scans data set was used for the development of a deep learning-based algorithm. This data set was split into an 8:2 ratio divided into a training set (80%, n = 915) and a validation set (20%, n = 229). The performance of the deep learning algorithm was evaluated in the test set (n = 240) using actual lung boundaries and radiographers' scan ranges.

RESULTS: The mean differences between the upper and lower boundaries of the deep learning-based algorithm and the actual lung boundaries were 4.72 ± 3.15 mm and 16.50 ± 14.06 mm, respectively. The accuracy and over-scanning of the scan ranges generated by the system were 97.08% (233/240) and 0% (0/240) for the upper boundary, and 96.25% (231/240) and 29.58% (71/240) for the lower boundary.

CONCLUSION: The developed deep learning-based algorithm system can effectively predict lung cancer screening low-dose CT scan range with high accuracy using only the frontal scout.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Ruan, Meng, Zhao, et al. Development of Deep Learning-based Automatic Scan Range Setting Model for Lung Cancer Screening Low-dose CT Imaging. Acad Radiol. 2022. PMID: 35131147. doi:10.1016/j.acra.2021.12.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。