骨质疏松患者椎体强化术后再发骨折的临床、影像与手术危险因素评估
回顾性分析2019年1月至2020年12月接受椎体强化的腰椎骨质疏松性椎体压缩骨折患者,比较再骨折组与非再骨折组的临床、影像及手术指标。再骨折组既往骨折、多发骨折及骨水泥渗漏发生率更高,腰大肌相对横截面积更小,多裂肌与竖脊肌脂肪浸润等指标更大。既往骨折、骨水泥渗漏、术后腰椎前凸角及椎体角度矫正度是独立危险因素,椎体角度矫正度预测准确性最高,临界值为3.45°。
要点
- 再骨折组骨水泥渗漏发生率显著高于非再骨折组。
- 椎体角度矫正度预测再骨折准确性最高,临界值3.45°。
- 既往骨折、骨水泥渗漏、术后腰椎前凸角及椎体角度矫正度为独立危险因素。
核心结论
- 后续骨折可能是多因素共同作用的结果,既往骨折、骨水泥渗漏、术后腰椎前凸角及椎体角度矫正度被确定为独立危险因素,椎体角度矫正度不应超过3.45°,尤其对于存在危险因素的患者。
研究设计与样本
- 回顾性研究,纳入2019年1月至2020年12月接受椎体强化的腰椎骨质疏松性椎体压缩骨折患者,非再骨折组128例、再骨折组16例;收集临床特征、影像参数(椎体压缩程度、脊柱矢状面序列、椎旁肌退变)及手术指标(骨水泥分布与渗漏、脊柱矢状面序列矫正)。
关键影像表现/征象
- 再骨折组腰大肌相对横截面积(r-CSAPS)显著小于非再骨折组。
- 再骨折组CSA比值、竖脊肌与多裂肌脂肪浸润(FIES+MF)、FIPS、术后腰椎前凸角(post-LL)、椎体角度矫正度(BA)及LL显著大于非再骨折组。
诊断标准与关键数值
- 椎体角度矫正度预测再骨折的ROC曲线临界值为3.45°。
- 二元logistic回归显示既往骨折、骨水泥渗漏、术后腰椎前凸角及椎体角度矫正度为独立危险因素。
临床应用与阅片要点
- 作者认为椎体角度矫正度不应超过3.45°,尤其对于存在危险因素的患者。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: Currently, the risk factors for subsequent fracture following vertebral augmentation remain incomplete and controversial. To provide clinicians with accurate information for developing a preventive strategy, we carried out a comprehensive evaluation of previously controversial and unexplored risk factors.
METHODS: We retrospectively reviewed patients with osteoporotic vertebral compression fracture in lumbar spine who received vertebral augmentation between January 2019 and December 2020. Based on whether refracture occurred, patients were assigned to refracture and non-refracture group. The clinical characteristics, imaging parameters (severity of vertebral compression, spinal sagittal alignment, degeneration of paraspinal muscles), and surgical indicators (cement distribution and leakage, correction of spinal sagittal alignment) were collected and analyzed.
RESULTS: There were 128 patients and 16 patients in non-refracture and refracture group. The incidence of previous fracture, multiple fractures, and cement leakage were notably higher, relative cross-sectional area of psoas (r-CSAPS) was significantly smaller, CSA ratio, fatty infiltration of erector spinae plus multifidus (FIES+MF), FIPS, postoperative lumbar lordosis (post-LL), correction of body angel (BA), and LL were significantly greater in refracture group. Binary logistic regression analysis revealed previous fracture, cement leakage, post-LL, and correction of BA were independent risk factors. According to the ROC curve, correction of BA showed the highest prediction accuracy, and the critical value was 3.45°.
CONCLUSIONS: The occurrence of subsequent fracture might be the consequence of multiple factors. Previous fracture, cement leakage, post-LL, and correction of BA were identified as independent risk factors. Furthermore, the correction of BA should not exceed 3.45°, especially in patients with risk factors.
引用
- Chen, Yao, Wu, et al. Assessment of clinical, imaging, surgical risk factors for subsequent fracture following vertebral augmentation in osteoporotic patients. Skeletal Radiol. 2022. PMID: 35122489. doi:10.1007/s00256-022-04009-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。