文献速递妇产影像儿科影像心血管US

共同动脉干产前诊断的准确性及影响

Accuracy and impact of prenatal diagnosis of common arterial trunk.
PubMed 文献 · Ultrasound Obstet Gynecol · 2022-06-30

本研究回顾性分析单中心2011–2019年84例共同动脉干(CAT)患者,评估产前诊断CAT解剖亚型及干瓣功能的准确性。产前诊断解剖亚型准确率80.3%,亚型一致性仅中等(κ=0.43);产前评估干瓣反流存在和严重程度一致性差(κ=0.09和0.19),但干瓣狭窄一致性尚可(κ=0.38和0.24)。产前诊断组干预更早、插管时间和总住院时间更短,但死亡率无差异。

要点

  • 产前诊断CAT解剖亚型准确率80.3%,但A3型均未产前诊断,A4型仅半数产前诊断。
  • 产前评估干瓣反流不可靠,常低估其存在和严重程度;干瓣狭窄一致性尚可。
  • 产前诊断组干预更早、插管和住院时间更短,但死亡率与产后诊断组无差异。

局限性

  • 单中心回顾性研究,样本量有限。
  • 部分病例为终止妊娠伴尸检,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Outcome of common arterial trunk (CAT) depends mainly on truncal valve function, presence of coronary artery abnormalities and presence of interrupted aortic arch. The main objective of this study was to evaluate the accuracy of prenatal diagnosis of CAT by analyzing prenatal vs postnatal assessment of: (1) anatomic subtypes and (2) truncal valve function. The secondary objective was to assess the potential impact of prenatal diagnosis of CAT on postnatal mortality and morbidity by comparing prenatally vs postnatally diagnosed patients.

METHODS: This was a retrospective analysis of all CAT patients diagnosed either prenatally, with postnatal or fetopsy confirmation, or postnatally, from 2011 to 2019 in a single tertiary center. Cohen's kappa statistic was used to evaluate agreement between pre- and postnatal assessment of anatomic subtypes according to Van Praagh and of truncal valve function. Mortality and morbidity variables were compared between prenatally vs postnatally diagnosed CAT patients.

RESULTS: A total of 84 patients (62 liveborn with prenatal diagnosis, 16 liveborn with postnatal diagnosis and six terminations of pregnancy with fetopsy) met the inclusion criteria. The accuracy of prenatal diagnosis of CAT anatomic subtype was 80.3%, and prenatal and postnatal concordance for subtype diagnosis was only moderate (κ = 0.43), with no patient with CAT Type A3 (0/4) and only half of patients with CAT Type A4 (8/17) being diagnosed prenatally. Fetal evaluation of truncal valve function underestimated the presence (no agreement; κ = 0.09) and severity (slight agreement; κ = 0.19) of insufficiency. However, four of five cases of postnatally confirmed significant truncal valve stenosis were diagnosed prenatally, with fair agreement for both presence and severity of stenosis (κ = 0.38 and 0.24, respectively). Mortality was comparable in patients with and those without prenatal diagnosis (log-rank P = 0.87). CAT patients with fetal diagnosis underwent earlier intervention (P < 0.001), had shorter intubation time (P = 0.047) and shorter global hospital stay (P = 0.01).

CONCLUSIONS: The accuracy of prenatal diagnosis of CAT is insufficient to tailor neonatal management and to predict outcome. Fetal assessment of truncal valve dysfunction appears unreliable due to perinatal transition. Improvement is necessary in the fetal diagnosis of anatomic subtypes of CAT requiring postnatal prostaglandin infusion. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Laux, Derridj, Stirnemann, et al. Accuracy and impact of prenatal diagnosis of common arterial trunk. Ultrasound Obstet Gynecol. 2022. PMID: 35118719. doi:10.1002/uog.24873

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。