文献速递妇产影像MR

扩散峰度成像评估子宫内膜纤维化:一项初步临床研究

Diffusion kurtosis imaging for assessing endometrial fibrosis: a preliminary clinical study.
PubMed 文献 · Abdom Radiol (NY) · 2022-02-03

本研究纳入40例宫腔镜确诊的子宫内膜纤维化患者和30名健康女性,行含DKI序列的MRI检查,测量子宫内膜厚度、ADC、校正ADC(D)和扩散峰度(K),并用ROC曲线评估诊断效能。结果显示纤维化组子宫内膜更薄,ADC和D值显著降低,K值显著升高,各参数诊断AUC为0.853–0.940,ADC的AUC最高且优于K。

要点

  • 子宫内膜纤维化患者ADC和D值降低、K值升高,K值升高反映扩散受限与组织复杂性增加。
  • ADC诊断子宫内膜纤维化的AUC为0.940,高于K的0.860,差异有统计学意义。
  • ADC、D、K在纤维化患者与健康对照中的重复性均优(ICC 0.951–0.991)。

核心结论

  • 子宫内膜DKI对无创评估子宫内膜纤维化具有前景。

研究设计与样本

  • 初步临床研究,纳入40例宫腔镜确诊的子宫内膜纤维化患者和30名健康女性,行包含DKI序列(b=0、500、1000、1500、2000 s/mm²)的MRI检查,以宫腔镜为参考标准。

关键影像表现/征象

  • 纤维化组子宫内膜厚度较健康对照组薄(P < 0.001)。
  • 纤维化组子宫内膜ADC和D值显著低于健康对照组(均P < 0.001)。
  • 纤维化组子宫内膜K值显著高于健康对照组(P < 0.001)。

诊断标准与关键数值

  • ADC诊断子宫内膜纤维化的AUC为0.940。
  • D诊断子宫内膜纤维化的AUC为0.879。
  • K诊断子宫内膜纤维化的AUC为0.860。
  • 子宫内膜厚度(ET)诊断子宫内膜纤维化的AUC为0.853。
  • ADC的AUC高于K(z = 2.307,P < 0.05);D、K、ET之间以及ADC、D、ET之间的AUC差异均无统计学意义(均P > 0.05)。

临床应用与阅片要点

  • 作者认为子宫内膜DKI对无创评估子宫内膜纤维化具有前景。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the feasibility of using diffusion kurtosis imaging (DKI) for the assessment of endometrial fibrosis.

METHODS: 40 patients with hysteroscopy confirmed endometrial fibrosis and 30 healthy women underwent MR examination including the DKI sequence (b = 0, 500, 1000, 1500, and 2000 s/mm2). Endometrial thickness (ET), apparent diffusion coefficient (ADC), corrected ADC (D), and kurtosis of diffusion (K) were measured and compared, and the diagnostic performance of those parameters was evaluated using ROC curves analysis.

RESULTS: Patients with endometrial fibrosis had a thinner endometrium than the healthy controls (P < 0.001). They also had significantly lower ADC and D values and significantly higher K values of the endometrium than the healthy controls (all P < 0.001). ADC, D, K, and ET all performed excellently in diagnosing endometrial fibrosis, with areas under the curve (AUCs) of 0.940, 0.879, 0.860, and 0.853, respectively. ADC showed the highest AUC, demonstrating better diagnostic accuracy than K (z = 2.307, P < 0.05). However, there were no differences in AUC between D, K, and ET, or ADC, D, and ET (all P > 0.05). The reproducibility of ADC, D, and K values in patients with endometrial fibrosis and healthy controls was excellent (ICC 0.951-0.991).

CONCLUSION: DKI of the endometrium has promising potential for the noninvasive assessment of endometrial fibrosis.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Hu, Jiang, Feng, et al. Diffusion kurtosis imaging for assessing endometrial fibrosis: a preliminary clinical study. Abdom Radiol (NY). 2022. PMID: 35113173. doi:10.1007/s00261-022-03413-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。