对比增强磁共振成像灌注可预测1至5厘米肝细胞癌的微血管侵犯
回顾性纳入80例1–5 cm肝细胞癌患者(43例MVI阳性、42例MVI阴性),行全肝灌注MRI测量Fa、Fp、Ft、ART、DV、MTT。MVI阳性组Fp显著高于阴性组而ART相反;肿瘤大小、Fp、ART为MVI独立危险因素,三者联合AUC为0.931,敏感度97.6%、特异度76.2%。
要点
- MVI阳性肝细胞癌Fp显著高于MVI阴性,ART则相反(p<0.001)。
- 肿瘤大小、Fp、ART为MVI独立危险因素,OR分别为3.20、3.09、12.13。
- 三者联合诊断MVI的AUC为0.931,敏感度97.6%、特异度76.2%。
核心结论
- 在1–5 cm肝细胞癌中,Fp、ART与肿瘤大小三者联合评估MVI的诊断准确率高于任一参数单独使用。
研究设计与样本
- 回顾性研究,经机构审查委员会批准,纳入80例患者(43例MVI阳性、42例MVI阴性)肝细胞癌;采用笛卡尔k空间欠采样与压缩感知重建的全肝灌注MRI,注射0.1 mmol/kg钆喷酸葡胺后,基于双输入单室模型测量Fa、Fp、Ft=Fa+Fp、ART、DV、MTT。
诊断标准与关键数值
- MVI阳性组Fp显著高于MVI阴性组,ART则相反(p<0.001);简单与多元回归显示肿瘤大小(β=1.2,p=0.004;OR 3.20,95%CI 1.45–7.06)、Fp(β=1.1,p=0.004;OR 3.09,95%CI 1.42–6.72)、ART(β=-3.1,p=0.001;OR 12.13,95%CI 2.85–51.49)为MVI独立危险因素;三者联合AUC 0.931(95%CI 0.855–0.975),敏感度97.6%、特异度76.2%。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the role of perfusion parameters with MR imaging of the liver in diagnosing MVI in hepatocellular carcinoma (HCC) (between 1 and 5 cm).
MATERIALS AND METHODS: This retrospective study was approved by the institutional review board. In 80 patients with 43 MVI( +) and 42 MVI( -) HCC, whole-liver perfusion MR imaging with Cartesian k-space undersampling and compressed sensing reconstruction was performed after injection of 0.1 mmol/kg gadopentetate dimeglumine. Parameters derived from a dual-input single-compartment model of arterial flow (Fa), portal venous flow (Fp), total blood flow (Ft = Fa + Fp), arterial fraction (ART), distribution volume (DV), and mean transit time (MTT) were measured. The significant parameters between the two groups were included to correlate with the presence of MVI at simple and multiple regression analysis.
RESULTS: In MVI-positive HCC, Fp was significantly higher than in MVI-negative HCC, whereas the reverse was seen for ART (p < 0.001). Tumor size (β = 1.2, p = 0.004; odds ratio, 3.20; 95% CI 1.45, 7.06), Fp (β = 1.1, p = 0.004; odds ratio, 3.09; 95% CI 1.42, 6.72), and ART (β = - 3.1, p = 0.001; odds ratio, 12.13; 95% CI 2.85, 51.49) were independent risk factors for MVI. The AUC value of the combination of all three metrics was 0.931 (95% CI 0.855, 0.975), with sensitivity of 97.6% and specificity of 76.2%.
CONCLUSION: The combination of Fp, ART, and tumor size demonstrated a higher diagnostic accuracy compared with each parameter used individually when evaluating MVI in HCC (between 1 and 5 cm).
引用
- Wu, Yang, Halim, et al. Contrast-enhanced magnetic resonance imaging perfusion can predict microvascular invasion in patients with hepatocellular carcinoma (between 1 and 5 cm). Abdom Radiol (NY). 2022. PMID: 35113174. doi:10.1007/s00261-022-03423-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。