双能CT鉴别眼眶良恶性肿瘤

Differentiation of malignant from benign orbital tumours using dual-energy CT.
PubMed 文献 · Clin Radiol · 2022-01-31

回顾性分析41例经组织病理学确认的眼眶肿瘤患者,采用128层双源CT行对比增强双能CT,测定碘浓度、有效原子序数及40–120 keV虚拟单能图像等参数。恶性眼眶肿瘤的碘浓度、标准化碘浓度、有效原子序数、40–105 keV虚拟单能图像CT衰减值及斜率k值均显著高于良性肿瘤(p<0.05)。40 keV虚拟单能图像单参数诊断效能最高(AUC 0.940),联合参数诊断效能最佳(AUC 0.971;敏感度90%,特异度93.55%);双能CT辐射剂量较常规CT显著降低(p<0.001)。

要点

  • 恶性眼眶肿瘤的碘浓度、标准化碘浓度、有效原子序数及40–105 keV虚拟单能图像CT衰减值均显著高于良性肿瘤。
  • 40 keV虚拟单能图像单参数诊断AUC为0.940,联合参数AUC为0.971、敏感度90%、特异度93.55%。
  • 双能CT辐射剂量较常规CT显著降低(p<0.001)。

核心结论

  • 定量双能CT分析可用于鉴别眼眶良恶性肿瘤,诊断准确率优异,且辐射剂量低。

研究设计与样本

  • 回顾性分析2019年11月至2021年3月41例眼眶肿瘤患者,采用128层双源CT行对比增强双能CT,以组织病理学为参考标准。

关键影像表现/征象

  • 恶性眼眶肿瘤的碘浓度、标准化碘浓度、有效原子序数、40–105 keV虚拟单能图像CT衰减值及斜率k值均显著高于良性眼眶肿瘤(p<0.05)。

诊断标准与关键数值

  • 40 keV虚拟单能图像单参数诊断效能最高,AUC为0.940。
  • 联合参数诊断效能最佳,AUC为0.971,敏感度90%,特异度93.55%。

临床应用与阅片要点

  • 双能CT定量参数(碘浓度、标准化碘浓度、有效原子序数、40–105 keV虚拟单能图像CT衰减值及斜率k值)可用于鉴别眼眶良恶性肿瘤。
  • 联合参数诊断效能最佳(AUC 0.971;敏感度90%;特异度93.55%),40 keV虚拟单能图像为单参数中最高(AUC 0.940)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the diagnostic accuracy of dual-energy computed tomography (DECT)-derived iodine concentration (IC), effective atomic number (Zeff), and spectral attenuation information for differentiating malignant and benign orbital tumours.

MATERIALS AND METHODS: Data from 41 patients with orbital tumours from November 2019 to March 2021 were analysed retrospectively. Each patient underwent contrast-enhanced DECT using a 128-section dual-source computed tomography (DSCT) system. Dual-energy information, including IC, normalised iodine concentration (NIC), Zeff, virtual monoenergetic images (VMIs) reconstructed from 40 to 120 keV and slope (k) value were determined. Quantitative measurement of DECT parameters was undertaken by two independent radiologists blinded to clinical data. Differences in parameters were assessed using independent sample t-test. Diagnosis performance was calculated by the receiver operating characteristic (ROC) curve analysis. Radiation doses of conventional CT and DECT were compared by paired t-tests.

RESULTS: Forty-one patients with histopathologically confirmed tumours were enrolled, including 10 malignant cases and 21 benign cases. Malignant orbital tumours exhibited significantly greater IC, NIC, Zeff, CT attenuation of VMIs at 40-105 keV, and k values compared to benign orbital tumours (p<0.05). In ROC analyses, 40 keV VMI demonstrated the highest diagnostic performance of single parameters (area under the ROC curve [AUC], 0.940), and combined parameters achieved the best performance (AUC, 0.971; sensitivity, 90%; specificity, 93.55%). Radiation doses were significantly reduced in DECT than conventional CT (p<0.001).

CONCLUSIONS: Quantitative DECT analysis can be a useful technique, which yields excellent diagnostic accuracy, in the differentiation of malignant and benign orbital tumours with low radiation dose.

来源:Clin Radiol,查看原文。版权归原作者所有。