深度学习图像重建在低剂量胸部CT扫描中的应用
前瞻性纳入48例成人患者,均行标准剂量CT(SDCT)与低剂量CT(LDCT),LDCT分别用DLIR-H、DLIR-M及ASIR-V40%重建。LDCT较SDCT辐射剂量降低96%(CTDIvol 0.54mGy vs 12.46mGy);低剂量DLIR-H图像噪声、主动脉CNR及整体图像质量与标准剂量ASIR-V40%图像无显著差异(均p>0.05)。
要点
- LDCT较SDCT辐射剂量降低96%(CTDIvol 0.54mGy vs 12.46mGy)。
- 低剂量DLIR-H图像噪声、主动脉CNR及整体图像质量与标准剂量ASIR-V40%图像无显著差异(均p>0.05)。
- LDCT中DLIR较ASIR-V40%显著降低图像噪声,DLIR-H噪声最低、图像质量评分最高。
核心结论
- DLIR显著降低低剂量胸部CT图像噪声,低剂量DLIR-H图像在4%辐射剂量下获得与标准剂量ASIR-V40%图像相似的图像质量。
研究设计与样本
- 前瞻性研究纳入48例成人患者(女30例、男18例,平均年龄49.8±14.3岁),均行标准剂量CT与低剂量CT,设备为GE Revolution CT扫描仪,所有扫描以ASIR-V40%重建,低剂量扫描另以DLIR-H和DLIR-M重建。
诊断标准与关键数值
- 低剂量DLIR-H图像与标准剂量ASIR-V40%图像在图像噪声、主动脉CNR及整体图像质量上无显著差异(均p>0.05)。
- 低剂量CT较标准剂量CT辐射剂量降低96%(CTDIvol 0.54mGy vs 12.46mGy)。
- 低剂量CT中DLIR较ASIR-V40%显著降低图像噪声,DLIR-H提供最低图像噪声和最高图像质量评分。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Deep learning image reconstruction (DLIR) is a new reconstruction method for maintaining image quality at reduced radiation dose. The purpose of this study was to compare image quality of reduced-dose DLIR images with the standard-dose adaptive statistical iterative reconstruction (ASIR-V) images in chest CT.
METHODS: Our prospective study included 48 adult patients (30 women and 18 men, mean age ±SD, 49.8 ± 14.3 years) who underwent both the standard-dose CT (SDCT) and low-dose CT (LDCT) on a GE Revolution CT scanner. All patients gave written informed consent. All scans were reconstructed with ASIR-V40%. Additionally, LDCT scans were reconstructed with DLIR with high-setting (DLIR-H) and medium-setting (DLIR-M). Image noise and contrast-noise-ratio (CNR) of thoracic aorta with different reconstruction modes were measured and compared.
RESULTS: LDCT reduced radiation dose by 96% compared with SDCT (CTDIvol: 0.54mGy vs 12.46mGy). In LDCT, DLIR significantly reduced image noise compared with the state-of-the-art ASIR-V40% with DLIR-H provided the lowest image noise and highest image quality score. In addition, the image noise, CNR of aorta and overall image quality of the low-dose DLIR-H images did not have significant difference compared with the SDCT ASIR-V40% images (all p > 0.05).
CONCLUSION: DLIR significantly reduces image noise in LDCT chest scans and provides similar image quality as the SDCT ASIR-V images at 4% of the radiation dose.
ADVANCES IN KNOWLEDGE: DLIR uses high-quality FBP data to train deep neural networks to learn how to distinguish between signal and noise, and effectively suppresses noise without affecting anatomical and pathological structures. It opens a new era of CT image reconstruction. DLIR significantly reduces image noise and improves image quality compared with ASIR-V40% under same radiation dose condition. DLIR-H achieves similar image quality at 4% radiation dose as ASIR-V40% at standard-dose level in non-contrast chest CT.
引用
- Wang, Li, Shang, et al. Application of deep learning image reconstruction in low-dose chest CT scan. Br J Radiol. 2022. PMID: 35084210. doi:10.1259/bjr.20210380
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。