文献速递心血管胸部CTUS

非门控CT肺动脉血管成像自动心腔容积测定在2018年更新血流动力学定义下检测肺动脉高压的效用

Utility of Automated Cardiac Chamber Volumetry by Nongated CT Pulmonary Angiography for Detection of Pulmonary Hypertension Using the 2018 Updated Hemodynamic Definition.
PubMed 文献 · AJR Am J Roentgenol · 2022-01-26

回顾性纳入109例疑似肺动脉高压患者,评估非门控CTPA自动心腔容积测量诊断肺动脉高压的效能,以2018年更新血流动力学定义为参考。右心室/左心室容积比和右心房容积的AUC均为0.791;联合超声肺动脉收缩压与CTPA右心房容积的模型AUC为0.898,敏感度83.3%,特异度85.7%。

要点

  • 非门控CTPA自动容积测量中,右心房容积和右心室/左心室容积比诊断肺动脉高压的AUC最高,均为0.791。
  • 校正年龄、性别和体表面积后,右心房容积每增加10 mL的OR为1.27,右心室/左心室容积比的OR为2.91。
  • 联合超声肺动脉收缩压与CTPA右心房容积的预测模型AUC为0.898,敏感度83.3%,特异度85.7%。

核心结论

  • 基于非门控CTPA的自动心腔容积测定,尤其是右心房容积,相对于超声和传统CTPA参数对肺动脉高压诊断具有增量效用。

研究设计与样本

  • 回顾性研究纳入2013年8月至2016年2月因疑似肺动脉高压行非门控CTPA、经胸超声心动图和右心导管检查的109例患者(72例女性,37例男性;中位年龄68岁)。

关键影像表现/征象

  • 肺动脉高压患者右心室容积为172.6 mL,无肺动脉高压患者为118.1 mL(p < .05)。
  • 肺动脉高压患者右心房容积为130.2 mL,无肺动脉高压患者为77.0 mL(p < .05)。
  • 所有容积测量的观察者内和观察者间一致性均极好(组内相关系数0.935-0.999)。

诊断标准与关键数值

  • 以2018年第六届世界肺动脉高压研讨会血流动力学定义(PH20)为参考,右心室/左心室容积比和右心房容积诊断肺动脉高压的AUC均为0.791。
  • 校正年龄、性别和体表面积后,右心室容积每10 mL的OR为1.21,右心房容积每10 mL的OR为1.27,右心室/左心室容积比的OR为2.91,右心房/左心房容积比的OR为11.22。
  • 联合超声肺动脉收缩压和CTPA右心房容积的预测模型AUC为0.898,敏感度83.3%,特异度85.7%。

临床应用与阅片要点

  • 在疑似肺动脉高压患者的非门控CTPA中,可关注自动分割获得的右心房容积和右心室/左心室容积比,作为提示肺动脉高压的影像指标。
  • 联合超声肺动脉收缩压与CTPA右心房容积的模型有助于无创识别需进一步右心导管检查的患者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Noninvasive tests for pulmonary hypertension (PH) are needed to help select patients for diagnostic right heart catheterization (RHC). CT pulmonary angiography (CTPA) is commonly performed for suspected PH. OBJECTIVE. The purpose of this study was to assess the utility of CTPA-based cardiac chamber volumetric measurements for the diagnosis of PH in comparison with echocardiographic and conventional CTPA parameters, with the 2018 updated hemodynamic definition used as reference. METHODS. This retrospective study included 109 patients (72 women and 37 men; median age, 68 years) who underwent nongated CTPA, transthoracic echocardiography, and RHC for the workup of suspected PH between August 2013 and February 2016. Two radiologists independently used automated 3D segmentation software to determine the volumes of the right ventricle (RV), right atrium (RA), left ventricle (LV), and left atrium (LA) and also measured the axial diameters of the cardiac chambers, main pulmonary artery, and ascending aorta. Interobserver agreement was assessed, and mean values were obtained; one observer repeated volumetric measurements to assess intraobserver agreement. ROC analysis was used to assess diagnostic performance for the detection of PH. A multivariable binary logistic regression model was established. RESULTS. A total of 60 of 109 patients had PH. Intra- and interobserver agreements were excellent for all volume measurements (intraclass correlation coefficients, 0.935-0.999). In patients with PH versus those without PH, RV volume was 172.6 versus 118.1 mL, and RA volume was 130.2 versus 77.0 mL (both p < .05). Cardiac chamber measurements with the highest AUC for PH were the RV/LV volume ratio and RA volume (both 0.791). Significant predictors of PH20 (as defined using the 2018 hemodynamic definition from the Sixth World Symposium on Pulmonary Hypertension) after adjustment for age, sex, and body surface area included RV volume per 10 mL (odds ratio [OR], 1.21), RA volume per 10 mL (OR, 1.27), RV/LV volume ratio (OR, 2.91), and RA/LA volume ratio (OR, 11.22). Regression analysis yielded a predictive model for PH that contained two independent predictors: echocardiographic pulmonary arterial systolic pressure and CTPA-based RA volume; the model had an AUC of 0.898, sensitivity of 83.3%, and specificity of 85.7%. CONCLUSION. Automated cardiac chamber volumetry using nongated CTPA, particularly of the RA, provides incremental utility relative to echocardiographic and conventional CTPA parameters for diagnosis of PH. CLINICAL IMPACT. Automated volumetry of cardiac chambers based on nongated CTPA may facilitate early noninvasive detection of PH, identifying patients who warrant further evaluation by RHC.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Melzig, Do, Egenlauf, et al. Utility of Automated Cardiac Chamber Volumetry by Nongated CT Pulmonary Angiography for Detection of Pulmonary Hypertension Using the 2018 Updated Hemodynamic Definition. AJR Am J Roentgenol. 2022. PMID: 35080457. doi:10.2214/AJR.21.27147

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。