双束双能模式与单能模式颈动脉CT血管造影图像质量的对比研究

Comparative study of the image quality of twin beam dual energy and single energy carotid CT angiography.
PubMed 文献 · Eur J Radiol · 2022-01-18

前瞻性研究纳入221例患者,比较双束双能模式低虚拟单能量图像与单能模式(80/90/120 kV)颈动脉CTA的图像质量。双能低keV虚拟单能量图像在客观噪声比和主观评分上优于单能低管电压扫描,主观最优keV为50 keV。

要点

  • 双束双能低keV虚拟单能量图像可提供优于单能低管电压扫描的颈动脉CTA图像质量
  • 低于56 keV的虚拟单能量图像对比噪声比高于80/90/120 kV单能扫描
  • 双能颈动脉CTA主观评分最优能量水平为50 keV(3.70±0.53)

核心结论

  • 新型双束双能技术结合低keV虚拟单能量重建可提供优于单能低管电压扫描的颈动脉CTA图像质量,主观最优keV为50 keV。

研究设计与样本

  • 前瞻性研究,221例患者分别行双束双能模式120 kV或单能模式80/90/120 kV扫描,各组55例,80 kV单能组56例;双能模式重建40–90 keV步长1 keV的虚拟单能量图像;两名观察者采用四点Likert量表评估13个动脉节段,以Cohen kappa检验评价观察者间一致性。

关键影像表现/征象

  • 颈动脉分叉水平感兴趣区:虚拟单能量图像能量低于79 keV时对比噪声比高于120 kV单能组(p=0.028),低于56 keV时高于90 kV单能组(p=0.037)
  • 颈总动脉起始部水平感兴趣区:虚拟单能量图像能量低于83 keV时对比噪声比高于120 kV单能组(p=0.015),低于60 keV时高于90 kV单能组(p=0.034)

诊断标准与关键数值

  • 颈动脉分叉水平:虚拟单能量图像对比噪声比高于120 kV单能组(p=0.028)的阈值为能量低于79 keV,高于90 kV单能组(p=0.037)的阈值为能量低于56 keV
  • 颈总动脉起始部水平:虚拟单能量图像对比噪声比高于120 kV单能组(p=0.015)的阈值为能量低于83 keV,高于90 kV单能组(p=0.034)的阈值为能量低于60 keV
  • 剂量归一化对比噪声比:120/90/80 kV单能组分别相当于颈动脉分叉水平的83/63/67 keV虚拟单能量图像,颈总动脉起始部水平的88/72/75 keV虚拟单能量图像
  • 主观评分最高为50 keV双束双能组(3.70±0.53),观察者间Kappa值0.79–0.85

临床应用与阅片要点

  • 双束双能颈动脉CTA可采用低keV虚拟单能量重建(如50 keV)以获得优于单能低管电压扫描的图像质量
  • 虚拟单能量图像能量低于56 keV时对比噪声比高于80/90/120 kV单能扫描

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to compare the image quality of low virtual monochromatic image (VMI) from the twin-beam dual energy (TBDE) mode to that from the single energy (SE) mode using both standard and low tube voltage acquisition in carotid computed tomography angiography (CTA).

METHODS: In this prospective study, 221 patients were imaged using TBDE mode with 120 kV or SE mode with 80/90/120 kV, patient numbers in all groups are equal(n = 55) except in the group using 80 kV SE mode(n = 56). VMIs ranging from 40 to 90 keV with a step of 1 keV were reconstructed from TBDE mode. In objective image quality assessment, regions of interest (ROIs) were placed in both carotid artery lumens and in both sternocleidomastoid muscles to calculate and compare the contrast-to-noise ratio (CNR) and the dose-normalized CNR (CNRD) among groups. In subjective assessment, a total of 13 arterial segments were assessed using a four-point Likert scale by two observers. Cohen's kappa test was used to quantify the level of agreement between the two observers.

RESULTS: For ROI1 at the level of the carotid bifurcation, VMIs showed a higher CNR than the 120 kV SE group (p = 0.028)/ 90 kV SE group (p = 0.037) when their energy level were lower than 79 keV (56.92 ± 16.01)/56 keV (90.08 ± 22.14) respectively. The 90 kV SE (80.68 ± 24.47) showed the best CNR in all the SE groups. For CNRD, the 120/90/80 kV SE group was equivalent to 83/63/67 keV VMIs respectively. For ROI2 at the level of the origin of the common carotid artery, VMIs also showed a higher CNR than the 120 kV SE group (p = 0.015)/90 kV SE group (p = 0.034) when their energy level were lower than 83 keV (46.31 ± 14.47)/60 keV (72.23 ± 16.96) respectively. The 90 kV SE (64.98 ± 18.51) showed the best CNR in all the SE groups. For CNRD, the 120/90/80 kV SE group was equivalent to 88/72/75 keV VMIs respectively. The highest subjective rating score was 50 keV TBDE(3.70 ± 0.53). Cohen's Kappa values(0.79-0.85) suggest a substantial level of agreement between the two observers.

CONCLUSIONS: The novel TBDE technique with low keV VMI reconstruction provides better image quality of carotid CTA than the low tube voltage scan in the SE mode. VMIs with a keV level below 56 keV have a higher CNR than those from SE scans with 80/90/120 kV. Subjectively, the optimal keV energy level in TBDE for carotid CT angiography is 50 keV.

来源:Eur J Radiol,查看原文。版权归原作者所有。