文献速递胸部介入DR

深度学习在经皮肺穿刺活检后胸片气胸检测中的临床应用

Deep Learning for Detecting Pneumothorax on Chest Radiographs after Needle Biopsy: Clinical Implementation.
PubMed 文献 · Radiology · 2022-01-25

本研究探讨深度学习计算机辅助检测(CAD)系统能否提高经皮肺穿刺活检(PTNB)后胸片上气胸的检测性能。实施CAD后(2020年2月至11月)与实施前(2018年1月至2020年1月)的回顾性队列比较显示,CAD应用组敏感度85.4% vs 67.1%、阴性预测值96.8% vs 91.3%、准确率96.8% vs 92.3%(均P<.001),少量气胸敏感度亦提高。

要点

  • CAD应用组气胸检测敏感度85.4% vs 非CAD组67.1%(P<.001)。
  • CAD应用组气胸<10%时敏感度74.5% vs 51.4%(P=.009)。
  • CAD应用组需引流管置入比例2.4% vs 非CAD组5.0%(P=.009)。

核心结论

  • 基于深度学习的计算机辅助检测系统提高了肺活检后胸片上气胸的检测性能。

研究设计与样本

  • 回顾性队列研究,CAD应用组连续纳入2020年2月至2020年11月676张胸片(655例患者,平均年龄67岁±11,390名男性),非CAD组连续纳入2018年1月至2020年1月676张胸片(664例患者,平均年龄66岁±12,400名男性);参考标准为两名放射科医师共识判读;采用广义估计方程比较两组诊断准确性,并按阅片者与PTNB操作者是否相同用贪心法进行匹配。

诊断标准与关键数值

  • CAD应用组敏感度85.4% vs 非CAD组67.1%,阴性预测值96.8% vs 91.3%,准确率96.8% vs 92.3%(均P<.001);气胸<10%时敏感度74.5% vs 51.4%(P=.009),气胸10%-15%时敏感度92.7% vs 70.2%(P=.008)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Accurate detection of pneumothorax on chest radiographs, the most common complication of percutaneous transthoracic needle biopsies (PTNBs), is not always easy in practice. A computer-aided detection (CAD) system may help detect pneumothorax. Purpose To investigate whether a deep learning-based CAD system can improve detection performance for pneumothorax on chest radiographs after PTNB in clinical practice. Materials and Methods A CAD system for post-PTNB pneumothorax detection on chest radiographs was implemented in an institution in February 2020. This retrospective cohort study consecutively included chest radiographs interpreted with CAD assistance (CAD-applied group; February 2020 to November 2020) and those interpreted before implementation (non-CAD group; January 2018 to January 2020). The reference standard was defined by consensus reading by two radiologists. The diagnostic accuracy for pneumothorax was compared between the two groups using generalized estimating equations. Matching was performed according to whether the radiograph reader and PTNB operator were the same using the greedy method. Results A total of 676 radiographs from 655 patients (mean age: 67 years ± 11; 390 men) in the CAD-applied group and 676 radiographs from 664 patients (mean age: 66 years ± 12; 400 men) in the non-CAD group were included. The incidence of pneumothorax was 18.2% (123 of 676 radiographs) in the CAD-applied group and 22.5% (152 of 676 radiographs) in the non-CAD group (P = .05). The CAD-applied group showed higher sensitivity (85.4% vs 67.1%), negative predictive value (96.8% vs 91.3%), and accuracy (96.8% vs 92.3%) than the non-CAD group (all P < .001). The sensitivity for a small amount of pneumothorax improved in the CAD-applied group (pneumothorax of <10%: 74.5% vs 51.4%, P = .009; pneumothorax of 10%-15%: 92.7% vs 70.2%, P = .008). Among patients with pneumothorax, 34 of 655 (5.0%) in the non-CAD group and 16 of 664 (2.4%) in the CAD-applied group (P = .009) required subsequent drainage catheter insertion. Conclusion A deep learning-based computer-aided detection system improved the detection performance for pneumothorax on chest radiographs after lung biopsy. © RSNA, 2022 See also the editorial by Schiebler and Hartung in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Hong, Hwang, Lee, et al. Deep Learning for Detecting Pneumothorax on Chest Radiographs after Needle Biopsy: Clinical Implementation. Radiology. 2022. PMID: 35076301. doi:10.1148/radiol.211706

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。