文献速递骨肌CTMR

基于MRI的髋关节合成CT:能否替代常规CT评估骨形态?

MRI-based synthetic CT of the hip: can it be an alternative to conventional CT in the evaluation of osseous morphology?
PubMed 文献 · Eur Radiol · 2022-01-23

前瞻性研究纳入27名受试者共54个髋关节,利用深度学习从MRI生成合成CT,两位读者独立测量髋臼前、后扇形角、髋臼版本角、关节间隙宽度、外侧中心边缘角、Sharp角、α角及股骨头颈偏移。结果显示合成CT与常规CT的所有测量值等效,在健康个体中可避免骨盆CT的辐射暴露。

要点

  • 基于MRI的合成CT与常规CT在髋关节骨形态定量测量上等效。
  • 合成CT由深度学习图像合成方法从MRI生成,无需额外扫描。
  • 在健康个体中可替代CT评估骨形态,避免骨盆CT辐射。

核心结论

  • 在健康个体中,基于MRI的合成CT与常规CT在定量评估髋关节骨形态方面等效,从而可避免骨盆CT检查的辐射暴露。

研究设计与样本

  • 前瞻性研究,纳入27名受试者共54个髋关节,所有受试者均接受髋关节MRI和CT检查;合成CT图像由基于深度学习的图像合成方法从MRI生成;两名读者独立在合成CT和CT上测量髋关节形态参数;采用组内相关系数、测量标准误和最小可检测变化评估方法间、读者间及读者内信度和一致性;采用等效性统计检验评估CT与合成CT的等效性。

诊断标准与关键数值

  • 基于信度和一致性参数观察到的 agreement 表明CT与合成CT之间高度一致;等效性统计检验显示,在所考虑的界值下,所有合成CT测量值均与CT测量值等效;测量参数包括髋臼前扇形角、髋臼后扇形角、髋臼版本角、关节间隙宽度、外侧中心边缘角、Sharp角、α角及股骨头颈偏移。

临床应用与阅片要点

  • 在健康个体中,基于MRI的合成CT与常规CT在定量评估髋关节骨形态方面等效;基于MRI的合成CT在术前诊断和手术规划中有应用前景。

局限性

  • 研究仅纳入无髋关节病变的健康个体。
  • 原文结论指出基于MRI的合成CT在术前诊断和手术规划中的应用前景,需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: MRI is the gold standard for soft tissue evaluation in the hip joint. However, CT is superior to MRI in providing clear visualization of bony morphology. The aim of this study is to test the equivalency of MRI-based synthetic CT to conventional CT in quantitatively assessing bony morphology of the hip.

MATERIALS AND METHODS: A prospective study was performed. Adult patients who underwent MRI and CT of the hips were included. Synthetic CT images were generated from MRI using a deep learning-based image synthesis method. Two readers independently performed clinically relevant measurements for hip morphology, including anterior and posterior acetabular sector angle, acetabular version angle, joint space width, lateral center-edge angle, sharp angle, alpha angle, and femoral head-neck offset on synthetic CT and CT. Inter-method, inter-reader, and intra-reader reliability and agreement were assessed using calculations of intraclass correlation coefficient, standard error of measurement, and smallest detectable change. The equivalency among CT and synthetic CT was evaluated using equivalency statistical testing.

RESULTS: Fifty-four hips from twenty-seven participants were included. There was no reported hip pathology in the subjects. The observed agreement based on reliability and agreement parameters indicated a strong degree of concordance between CT and synthetic CT. Equivalence statistical testing showed that all synthetic CT measurements are equivalent to the CT measurements at the considered margins.

CONCLUSION: In healthy individuals, we demonstrated equivalency of MRI-based synthetic CT to conventional CT for the quantitative evaluation of osseous hip morphology, thus obviating the radiation exposure of a pelvic CT examination.

KEY POINTS: •MRI-based synthetic CT images can be generated from MRI using a deep learning-based image synthesis method. •MRI-based synthetic CT is equivalent to CT in the quantitative assessment of bony hip morphology in healthy individuals. •MRI-based synthetic CT is promising for use in preoperative diagnosis and surgery planning.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Morbée, Chen, Van Den Berghe, et al. MRI-based synthetic CT of the hip: can it be an alternative to conventional CT in the evaluation of osseous morphology? Eur Radiol. 2022. PMID: 35066635. doi:10.1007/s00330-021-08442-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。