基于表观扩散系数图机器学习影像组学特征鉴别睾丸良恶性肿块:与常规平均及最小ADC值的比较
本回顾性研究纳入97例患者共101个经组织病理学证实的睾丸肿块(恶性70个、良性31个),从术前ADC图提取851个影像组学特征构建机器学习影像组学特征,并与最小及平均ADC值比较分类性能。全病灶平均ADC在良恶性组间无差异(训练队列P=0.070,验证队列P=0.418);影像组学特征在训练队列AUC为0.904(95%CI 0.832-0.975)、验证队列AUC为0.868(95%CI 0.728-1.00),均高于最小ADC。结论认为常规平均ADC值并不总是有助于鉴别睾丸良恶性,最小ADC和影像组学特征可能是更好的替代指标,其中影像组学特征表现优于最小ADC。
要点
- 全病灶平均ADC在良恶性睾丸肿块间无差异(训练队列P=0.070,验证队列P=0.418)。
- ADC影像组学特征训练队列AUC 0.904(95%CI 0.832-0.975),验证队列AUC 0.868(95%CI 0.728-1.00)。
- 影像组学特征AUC高于最小ADC,最小ADC和影像组学特征可能是更好的替代指标。
核心结论
- 常规平均ADC值并不总是有助于鉴别睾丸良恶性,最小ADC和影像组学特征可能是更好的替代指标,其中影像组学特征表现优于最小ADC。
研究设计与样本
- 回顾性研究,纳入97例患者共101个经组织病理学证实的睾丸肿块(恶性70个、良性31个),从每个病灶术前ADC图提取851个影像组学特征,随机选取30个病灶评估特征可靠性,采用单因素分析(独立t检验和Mann-Whitney U检验)及Spearman秩相关剔除冗余特征,LASSO算法进行特征选择和影像组学特征生成,以ROC曲线分析和DeLong检验比较影像组学特征与最小、平均ADC值的分类性能。
诊断标准与关键数值
- 全病灶平均ADC在良恶性睾丸肿块间无差异(训练队列P=0.070,验证队列P=0.418);影像组学特征训练队列AUC 0.904(95%CI 0.832-0.975),验证队列AUC 0.868(95%CI 0.728-1.00),均高于最小ADC。
临床应用与阅片要点
- 原文结论认为常规平均ADC值并不总是有助于鉴别睾丸良恶性,最小ADC和影像组学特征可能是更好的替代指标,影像组学特征表现优于最小ADC。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To develop a machine-learning-based radiomics signature of ADC for discriminating between benign and malignant testicular masses and compare its classification performance with that of minimum and mean ADC.
METHODS: A total of ninety-seven patients with 101 histopathologically confirmed testicular masses (70 malignancies, 31 benignities) were evaluated in this retrospective study. Eight hundred fifty-one radiomics features were extracted from the preoperative ADC map of each lesion. The mean and minimum ADC values are part of the radiomics features. Thirty lesions were randomly selected to estimate the reliability of the features. The redundant features were eliminated using univariate analysis (independent t test and Mann-Whitney U test, where appropriate) and Spearman's rank correlation. The least absolute shrinkage and selection operator (LASSO) algorithm was employed for feature selection and radiomics signature generation. The classification performance of the radiomics signature and minimum and mean ADC values were evaluated by receiver operating characteristic (ROC) curve analysis and compared by DeLong's test.
RESULTS: The whole lesion-based mean ADC showed no difference between benign and malignant testicular masses (P = 0.070, training cohort; P = 0.418, validation cohort). Compared with the minimum ADC, the ADC-based radiomics signature yielded a higher area under the curve (AUC) in both the training (AUC: 0.904, 95% confidence interval [CI]: 0.832-0.975) and validation cohorts (AUC: 0.868, 95% CI: 0.728-1.00).
CONCLUSIONS: Conventional mean ADC values are not always helpful in discriminating between testicular benignities and malignancies. The minimum ADC and radiomics signature might be better alternatives, with the radiomics signature performing better than the minimum ADC.
引用
- Fan, Sun, Min, et al. Discriminating malignant from benign testicular masses using machine-learning based radiomics signature of appearance diffusion coefficient maps: Comparing with conventional mean and minimum ADC values. Eur J Radiol. 2022. PMID: 35066342. doi:10.1016/j.ejrad.2022.110158
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。