文献速递心血管CT

双源光子计数探测器CT心脏延迟增强扫描定量细胞外容积

Extracellular Volume Quantification With Cardiac Late Enhancement Scanning Using Dual-Source Photon-Counting Detector CT.
PubMed 文献 · Invest Radiol · 2022-01-21

本研究纳入30例重度主动脉瓣狭窄患者,在经导管主动脉瓣置换术前使用双源光子计数探测器CT行心脏延迟增强扫描,评估细胞外容积定量的可行性与准确性。延迟增强扫描中位剂量长度乘积为84 mGy·cm,双能碘图与单能减影法计算的细胞外容积相关性好(r=0.87),Bland-Altman分析平均误差小(0.9%)。

要点

  • 双源光子计数探测器CT延迟增强扫描可在低辐射剂量下完成全心肌细胞外容积定量
  • 基于延迟增强扫描碘比值的细胞外容积计算无需真正平扫,且不受两次扫描间配准不良影响
  • 双能碘图与单能减影法计算的细胞外容积相关性好(r=0.87),平均误差0.9%

核心结论

  • 双源光子计数探测器CT使用低剂量心脏延迟增强双能扫描可准确量化细胞外容积;基于延迟增强扫描碘比值的细胞外容积计算无需获取真正平扫,且不受两次独立扫描间潜在配准不良的影响。

研究设计与样本

  • 经机构审查委员会批准的研究,纳入30例重度主动脉瓣狭窄患者(平均年龄79岁,12例女性,平均体重指数28 kg/m²),在经导管主动脉瓣置换术前使用双源光子计数探测器CT行术前检查。

关键影像表现/征象

  • 延迟增强扫描重建虚拟单能(65 keV)和双能碘图,并基于延迟增强扫描与平扫的单能减影计算细胞外容积。
  • 全心肌三维分析通过匹配由相应冠状动脉CT血管成像数据生成的心脏模型自动完成。
  • 两处局灶性细胞外容积升高与已知既往心肌梗死相符。

诊断标准与关键数值

  • 延迟增强扫描中位剂量长度乘积为84 mGy·cm(四分位距69;125 mGy·cm)。
  • 中位细胞外容积值为30.5%(四分位距28.4%-33.6%)。
  • 双能与单能减影法细胞外容积定量相关性好(r=0.87,P<0.001)。
  • Bland-Altman分析显示双能与单能减影法细胞外容积定量间平均误差小(0.9%;95%CI 0.1%-1.6%),一致性界限窄(-3.3%至5.0%)。

临床应用与阅片要点

  • 延迟增强扫描在注射100 mL对比剂后5分钟进行,为低剂量扫描,所有扫描均心电门控。
  • 基于延迟增强扫描碘比值计算细胞外容积可省去真正平扫采集,并避免两次独立扫描间配准不良的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to evaluate the feasibility and accuracy of cardiac late enhancement (LE) scanning for extracellular volume (ECV) quantification with dual-source photon-counting detector computed tomography (PCD-CT).

MATERIALS AND METHODS: In this institutional review board-approved study, 30 patients (mean age, 79 years; 12 women; mean body mass index, 28 kg/m2) with severe aortic stenosis undergoing PCD-CT as part of their preprocedural workup for transcatheter aortic valve replacement were included. The scan protocol consisted of a nonenhanced calcium-scoring scan, coronary CT angiography (CTA) followed by CTA of the thoracoabdominal aorta, and a low-dose LE scan 5 minutes after the administration of 100 mL contrast media (all scans electrocardiogram-gated). Virtual monoenergetic (65 keV) and dual-energy (DE) iodine images were reconstructed from the LE scan. Extracellular volume was calculated using the iodine ratios of myocardium and blood-pool of the LE scan, and additionally based on single-energy (SE) subtraction of the nonenhanced scan from the LE scan. Three-dimensional analysis was performed automatically for the whole-heart myocardial volume by matching a heart model generated from the respective coronary CTA data. Bland-Altman and correlation analysis were used to compare the ECV values determined by both methods.

RESULTS: The median dose length product for the LE scan was 84 mGy·cm (interquartile range, 69; 125 mGy·cm). Extracellular volume quantification was feasible in all patients. The median ECV value was 30.5% (interquartile range, 28.4%-33.6%). Two focal ECV elevations matched known prior myocardial infarction. The DE- and SE-based ECV quantification correlated well (r = 0.87, P < 0.001). Bland-Altman analysis showed small mean errors between DE- and SE-based ECV quantification (0.9%; 95% confidence interval, 0.1%-1.6%) with narrow limits of agreement (-3.3% to 5.0%).

CONCLUSIONS: Dual-source PCD-CT enables accurate ECV quantification using an LE cardiac DE scan at low radiation dose. Extracellular volume calculation from iodine ratios of the LE scan obviates the need for acquisition of a true nonenhanced scan and is not affected by potential misregistration between 2 separate scans.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Mergen, Sartoretti, Klotz, et al. Extracellular Volume Quantification With Cardiac Late Enhancement Scanning Using Dual-Source Photon-Counting Detector CT. Invest Radiol. 2022. PMID: 35066531. doi:10.1097/RLI.0000000000000851

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。