对比增强与虚拟单能图像能量水平对肺气肿定量的影响:光子计数探测器CT的初步经验
回顾性纳入60例在双源光子计数探测器CT上行对比增强胸部CT的患者,重建虚拟平扫及40–80 keV虚拟单能图像。对比增强导致肺气肿定量较虚拟平扫显著系统性低估,低估程度随虚拟单能图像能量升高而减小,80 keV与虚拟平扫结果最接近,60/70 keV在图像质量上权衡最佳。
要点
- 对比增强CT会显著低估肺气肿定量,报告肺气肿定量时需注意对比剂影响。
- 虚拟单能图像能量越高,肺气肿定量越接近虚拟平扫,80 keV差异最小。
- 60/70 keV在主观图像质量与定量评估之间取得最佳权衡。
核心结论
- CT肺气肿定量受静脉对比剂和虚拟单能图像能量水平的显著影响。
- 80 keV虚拟单能图像与虚拟平扫的肺气肿定量结果最接近。
- 定性及定量图像质量评估的最佳权衡点位于60/70 keV。
研究设计与样本
- 回顾性纳入60例在一代临床双源光子计数探测器CT上行对比增强胸部CT的患者。
- 扫描采用多能量模式(QuantumPlus)120 kV,经静脉注射体重调整对比剂。
- 重建虚拟平扫及40至80 keV、间隔10 keV的虚拟单能图像。
- 以虚拟平扫作为肺气肿定量的参考标准,采用商用软件以-950 HU为阈值进行定量。
关键影像表现/征象
- 噪声与对比噪声比随虚拟单能图像能量呈强负相关(r=-0.98;P<0.01)。
- 主观评估评分在肺实质评估以70 keV最高,在肺血管评估以50 keV最高(P<0.001)。
- 在评估肺气肿并维持肺血管合理对比度的最佳权衡点位于60至70 keV之间。
- 对比增强图像较虚拟平扫显著且系统性低估肺气肿(P<0.001),该低估随虚拟单能图像能量升高而减小(r=0.98;P=0.003)。
- 随虚拟单能图像能量升高,肺气肿定量体积显著增加(P<0.05),但60–70 keV与70–80 keV之间除外。
诊断标准与关键数值
- 肺气肿定量阈值:-950 HU。
- 对比增强扫描与虚拟平扫肺气肿定量的最小差异见于80 keV。
- 噪声定义为皮下脂肪衰减的标准差,对比噪声比感兴趣区置于升主动脉,信噪比于皮下脂肪计算。
临床应用与阅片要点
- 对比增强胸部CT上的肺气肿定量较虚拟平扫系统性偏低,判读时需考虑对比剂影响。
- 若需在增强扫描上评估肺气肿,80 keV虚拟单能图像与虚拟平扫结果最接近。
- 兼顾肺气肿评估与肺血管对比度时,60/70 keV为最佳权衡能量水平。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of this study was to evaluate the impact of contrast enhancement and different virtual monoenergetic image energies on automatized emphysema quantification with photon-counting detector computed tomography (PCD-CT).
MATERIAL AND METHODS: Sixty patients who underwent contrast-enhanced chest CT on a first-generation, clinical dual-source PCD-CT were retrospectively included. Scans were performed in the multienergy (QuantumPlus) mode at 120 kV with weight-adjusted intravenous contrast agent. Virtual noncontrast (VNC) images as well as virtual monoenergetic images (VMIs) from 40 to 80 keV obtained in 10-keV intervals were reconstructed. Computed tomography attenuation was measured in the aorta. Noise was measured in subcutaneous fat and defined as the standard deviation of attenuation. Contrast-to-noise with region of interest in the ascending aorta and signal-to-noise ratio in the subcutaneous fat were calculated. Subjective image quality (and emphysema assessment, lung parenchyma evaluation, and vessel evaluation) was rated by 2 blinded radiologists. Emphysema quantification (with a threshold of -950 HU) was performed by a commercially available software. Virtual noncontrast images served as reference standard for emphysema quantification.
RESULTS: Noise and contrast-to-noise ratio showed a strong negative correlation (r = -0.98; P < 0.01) to VMI energies. The score of subjective assessment was highest at 70 keV for lung parenchyma and 50 keV for pulmonary vessel evaluation (P < 0.001). The best trade-off for the assessment of emphysema while maintaining reasonable contrast for pulmonary vessel evaluation was determined between 60 and 70 keV. Overall, contrast-enhanced imaging led to significant and systematic underestimation of emphysema as compared with VNC (P < 0.001). This underestimation decreased with increasing VMI-energy (r = 0.98; P = 0.003). Emphysema quantification showed significantly (P < 0.05) increased emphysema volumes with increasing VMI energies, except between 60-70 keV and 70-80 keV. The least difference in emphysema quantification between contrast-enhanced scans and VNC was found at 80 keV.
CONCLUSION: Computed tomography emphysema quantification was significantly affected by intravenous contrast administration and VMI-energy level. Virtual monoenergetic image at 80 keV yielded most comparable results to VNC. The best trade-off in qualitative as well as in quantitative image quality evaluation was determined at 60/70 keV.
引用
- Jungblut, Kronenberg, Mergen, et al. Impact of Contrast Enhancement and Virtual Monoenergetic Image Energy Levels on Emphysema Quantification: Experience With Photon-Counting Detector Computed Tomography. Invest Radiol. 2022. PMID: 35066533. doi:10.1097/RLI.0000000000000848
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。